DOWNLOAD Sony ZS-X7 Service Manual ↓ Size: 5.59 MB | Pages: 40 in PDF or view online for FREE

Model
ZS-X7
Pages
40
Size
5.59 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / S/M ZS-X7 99 US CAN
File
zs-x7.pdf
Date

Sony ZS-X7 Service Manual ▷ View online

– 13 –
Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
CFT1
450kHz
AM  FREQUENCY COVERAGE  ADJUSTMENT
Adjust part
Frequency display
reading on digital
voltmeter.
 L4
  530kHz
Adjustment Value : 0.9V
Standard Value : 0.85 – 0.95V
 
Confirmation
  1,710kHz
 4.6 – 5.8V
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
620kHz
CT3
1,400kHz
 TUNER  SECTION
 AM Section
BAND button :  AM
Volume :  MIN
 FM Section
BAND button : FM
Volume :  MIN
Adjustment Location :  Tuner boar d (See pa ge 14)
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust part
Frequency display
reading on digital
voltmeter.
 
Confirmation
  87.5MHz
1.55 – 1.85V
 L2
  108MHz
Adjustment Value : 4.0V
Standard Value : 3.9 – 4.1V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.5MHz
CT1
108MHz
AM  RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
FM RF signal
generator
22.5kHz frequency deviation by 
400Hz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01 
µ
F
set
16 
+
i
 jack (J501)
level meter
0 dB = 1
µ
V
SECTION 5
ELECTRICAL ADJUSTMENTS
– 14 –
Connect and Adjustment Location :
JW2
Digital voltmeter
100k 
JW2
CT1 : FM Tracking Adjustment
CT3 : AM Tracking Adjustment
L3 : AM Tracking Adjustment
L4 : AM Frequency 
       Coverage Adjustment
Frequency Coverage Adjustment
L1 : FM Tracking Adjustment
CFT1 : AM IF Adjustment
L2 : FM Frequency 
       Coverage Adjustment
[TUNER BOARD] (Component side)
– 15 –
SECTION 6
DIAGRAMS
6-1. EXPLANATION OF IC TERMINALS
IC801 SYSTEM CONTROL (CXP83620-016Q)
Pin No.
Pin name
I/O
Description
1
SCOR
I
CD SCOR input.
2
SENSE
I
CD SENS input..
3
R-MUTE
O
Radio muting signal output.
4
ADJ
O
DC 1.7V output for beep signal.
–––––––––––
5
BEEP
O
Beep signal output.
6
YMLD
O
LATCH signal output for ESP controller (IC704).
7
YMCLK
O
Serial clock output for ESP controller (IC704).
8
ZSENSE
I
Serial data input from ESP controller (IC704).
9
YMDATA
O
Serial data output for ESP controller (IC704).
10
SQCK
I
CD SQCK input.
11
SQSO
I
CD SUB Q data input.
12
P-CON
O
Power ON/OFF control signal output.
13
DOOR
I
CD door switch (S701) input.
14
LOAD
O
Battery check output.
15
XRST
O
System reset output.
16
LATCH
O
CD system LATCH output.
17
CLK
O
CD serial clock output.
18
DATA
O
CD serial data output.
19
C-MUTE
O
CD mute signal output.
20
ESP
O
ESP ON/OFF signal output.
21
INIT
Not used (OPEN).
22
SIMUKE
I
Destination detect input (Fixed at “H”).
23 – 25
KEY1-3
I
Key input.
26
REG-CHK
I
DC regrator output voltage detect input.
27
BACK UP-CHK
I
Back-up battery voltage detect input.
28
BATT-H
I
Main battery high voltage detect input.
29
BATT-M
I
Main battery low voltage detect input.
30
RESET
I
System reset input.
31
EXTAL
I
System clock oscillator input terminal (4.19MHz).
32
XTAL
O
System clock oscillator output terminal (4.19MHz).
33
VSS
Ground.
34
VL
I
Reference voltage input.
35 – 37
VLC1-3
I
Reference voltage input.
38 – 41
COMO 0-3
O
LCD common output.
42 – 62
SEG 0-20
O
LCD segment output.
63
V-CLK
O
Volume clock output.
64
DATA
O
Volume data output.
65
V-LATCH
O
Volume LATCH output.
66
RADIO
O
Function output for radio.
67
A-MUTE
O
Audio mute signal output.
68
BEEP-H/L
O
Beep level high/low select output.
69
TU-CLK
O
PLL IC clock output.
70
TU-DATA
O
PLL IC data output.
– 16 –
Pin No.
Pin name
I/O
Description
71
TU-CE
O
PLL IC chip enable output.
72
VDD
Power supply terminal (B+ 3.3V)
73
TX
O
Sub System clock oscillator output (32.768kHz).
74
TEX
I
Sub System clock oscillator input  (32.768kHz).
75
NC
Not used (OPEN).
–––––
76
CD
O
Function output for CD.
–––––––––––––––––––
77
KEY-CHK
O
Key operation enable output.
78
E. C
Connect to ADJ (4 pin).
79
R-COUNT
I
PLL IC data input.
80
SENS 2
I
CD SENS 2 input.
Page of 40
Display

Click on the first or last page to see other ZS-X7 service manuals if exist.