DOWNLOAD Sony ZS-X1 Service Manual ↓ Size: 3.19 MB | Pages: 51 in PDF or view online for FREE

Model
ZS-X1
Pages
51
Size
3.19 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
zs-x1.pdf
Date

Sony ZS-X1 Service Manual ▷ View online

13
ZS-X1
SECTION  4
TEST  MODE
CD  TEST  MODE
procedure:
1. Insert the disc (YEDS-18) (Part No. 3-702-101-01) (CD) or
(TCD-W082L) (Part No. J-2502-063-2) (CD-RW).
2. Press the 
[POWER]
 or 
[OPERATE]
 button to turn the power
on. (TOC read ended)
3. Set the test mode by momentarily shorting both of TAP (TEST-
A) on the LCD board. (The message “88” is displayed on the
liquid crystal display)
4. To release the test mode, press the 
[POWER]
 or 
[OPERATE]
button to turn the power off.
LCD  TEST  MODE
procedure:
1. Press the 
[POWER]
 or 
[OPERATE]
 button to turn the power
on.
2. Set the test mode by momentarily shorting both of TAP (TEST-
B) on the LCD board.
LCD DISPLAY
3. It repeats until any button is pressed.
Connecting Location:
– LCD BOARD (Conductor Side) –
TEST A
TEST B
1
All lighting (4 seconds)
r
2
COM0 lighting (2 seconds)
r
3
COM1 lighting (2 seconds)
r
4
COM2 lighting (2 seconds)
r
5
COM3 lighting (2 seconds)
t
Ver 1.1
14
ZS-X1
AM (MW/LW) IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
( ): Singapore, Korean, Australian models
AM VCO VOLTAGE ADJUSTMENT (US, CND, SP, KR, AUS)
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
530 (531) kHz
1.0 
± 0.05 V
Confirmation
1,710 (1,611) kHz
5.3 (4.8) 
± 0.7 V
( ): Singapore, Korean, Australian models
AM TRACKING ADJUSTMENT (US, CND)
Adjust for a maximum reading on level meter
L3
620 (621) kHz
CT3
1,400 (1,404) kHz
MW VCO VOLTAGE ADJUSTMENT (AEP, UK, IT, EE)
Frequency Display
Reading on Digital Voltmeter
531 kHz
0.9 
± 0.4 V
1,611 kHz
5.2 
± 0.5 V
MW TRACKING ADJUSTMENT (AEP, UK, IT, EE)
Adjust for a maximum reading on level meter
L3-1
621 kHz
CT3
1,404 kHz
LW VCO VOLTAGE ADJUSTMENT (AEP, UK, IT, EE)
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
153 kHz
0.6 
± 0.2 V
Confirmation
279 kHz
5.0 
± 0.1 V
LW TRACKING ADJUSTMENT (AEP, UK, IT, EE)
Adjust for a maximum reading on level meter
L3-2
162 kHz
CT5
261 kHz
FM IF ADJUSTMENT
Adjust for a minimum reading on level meter
T2
10.7 MHz
FM VCO VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L2
108 MHz
3.0 
± 0.2 V
Confirmation
87.5 MHz
1.3 
± 0.3 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
87.5 MHz
CT1
108 MHz
Adjustment and Connecting Location: TUNER board
(See page 15)
TUNER  SECTION
0 dB=1 
µ
V
[AM (MW/LW) ]
Setting:
Function: RADIO
Band: AM (US, CND, SP, KR, AUS)
MW or LW (AEP, UK, IT, EE)
[FM]
Setting:
Function: RADIO
Band: FM
• Repeat the procedures in each adjustment several times, and the
tracking adjustments should be finally done by the trimmer ca-
pacitors.
• Remove FM antenna in FM adjustment.
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: 
as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
3.2 
AUDIO board
CN302 pin 
2
AUDIO board
CN302 pin 
1
FM RF signal
generator
75 kHz frequency
deviation by 1 kHz
signal
Output level: 
as low as possible
+
level meter
AUDIO board
CN302 pin 
2
AUDIO board
CN302 pin 
1
set
3.2 
0.01 
µ
F
TUNER board
TP (GND)
TUNER board
TP (ANT)
digital voltmeter
TP (VT)
TP (GND)
100 k
TUNER board
SECTION  5
ELECTRICAL  ADJUSTMENTS
PRECAUTION
1. Setting
MEGA BASS : OFF
Ver 1.1
ZS-X1
15
15
FOCUS  BIAS  CHECK
procedure:
1. Connect the oscilloscope to TP (RF) and TP (VC) on the CD
board.
2. Set the CD test mode. (Refer to CD TEST MODE (See page
13))
3. Press the
u
button twice. (LCD DISPLAY “P –”)
Note:
If this check is performed continuously after the
TRAVERSE CHECK, press the
u
button once.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (
◊) in the
center of the waveform can be clearly distinguished.
5. To check CD-RW, turn the power off. Change discs to CD-
RW (TCD-W082L) (Part No. J-2502-063-2), then set the CD
test mode again. (Refer to CD TEST MODE (See page 13))
• RF signal reference waveform (eye pattern)
Connecting Location:
CD SECTION
Perform all CD section check in the test mode.
TRAVERSE  CHECK
procedure:
1. Connect an oscilloscope to TP (TE) and TP (VC) on the CD
board.
2. Set the CD test mode. (Refer to CD TEST MODE (See page
13))
3. Press the
u
button once. (LCD DISPLAY “F –”)
4. Confirm that the center of the oscilloscope waveform is at 0 V.
5. Confirm that the oscilloscope waveform Vp-p value is at 0.95
± 0.4 V.
6. To check CD-RW, turn the power off. Change discs to CD-
RW (TCD-W082L) (Part No. J-2502-063-2), then set the CD
test mode again. (Refer to CD TEST MODE (See page 13))
VOLT/DIV: 0.2 V (with the 10: 1 probe in use.)
TIME/DIV: 500 ns
CD:
1.0 
±
 0.3 Vp-p
CD-RW:
1.0 
±
 0.4 Vp-p
When observing the eye pattern, set the oscilloscope 
for AC range and raise vertical sensitivity.
VOLT/DIV: 0.2 V (with the 10:1 probe in use)
TIME/DIV :  1 ms
0 V
A
B
Vp-p=A+B
– CD BOARD (Conductor Side) –
TP
(TE)
TP
(VC)
TP
(RF)
Adjustment and Connecting Location:
– TUNER BOARD (Component Side) (US, CND, SP, KR, AUS) –
– TUNER BOARD (Conductor Side) –
L4
AM VCO Voltage Adjustment
L2
FM VCO Voltage Adjustment
AM Tracking Adjustment
CT3
L3
FM Tracking Adjustment
T1 AM IF Adjustment
T2 FM IF Adjustment
L1
CT1
– TUNER BOARD (Component Side) (AEP, UK, IT, EE) –
L4
LW VCO Voltage Adjustment
L2
FM VCO Voltage Adjustment
LW Tracking Adjustment
CT3
L3-2
FM Tracking Adjustment
T1 AM IF Adjustment
T2 FM IF Adjustment
L1
CT1
MW Tracking Adjustment
CT3
L3-1
TP
(VT)
TP
(GND)
TP
(ANT)
• Abbreviation
AUS : Australian model
CND : Canadian model
EE
: East European model
IT
: Italian model
KR
: Korean model
SP
: Singapore model
Ver 1.1
ZS-X1
16
16
SECTION  6
DIAGRAMS
6-1.
BLOCK  DIAGRAM  – CD Section –
SYSTEM
CONTROLLER
IC802 (1/2)
PD (I)
: CD PLAY
• R-ch is omitted due to same as L-ch.
• SIGNAL PATH
A
B
D
F
E
C
I-V AMP
DETECTOR
LD
PD
LASER DIODE
OPTICAL PICK-UP
BLOCK
(KSM-213RAP)
2-AXIS
DEVICE
(TRACKING)
(FOCUS)
A
D
C
B
F
E
LD
PD
F+
F–
T+
T–
3
BD (I)
6
F (I)
2
AC (I)
RF SIGNAL
GENERATOR
100
99
EQO (O)
RFI (I)
9
FEO (O)
5
E (I)
8
FEN (I)
96
TEO (O)
97
TEN (I)
AUTOMATIC
POWER
CONTROL
Q701
13
LD (O)
APC
12
DIGITAL
SIGNAL
PROCESSOR
17
18
12
11
27
SL+
SL–
T–
T+
F+
F–
SPINDLE
MOTOR DRIVE
M701
(SPINDLE)
SLED
MOTOR DRIVE
26
M702
(SLED)
TRACKING
COIL DRIVE
FOCUS
COIL DRIVE
SP+
SP–
3
24
20
9
TIN
(FIN)
14
OPOUT
FOCUS
COIL DRIVE
15
OPIN
(SLIN)
SPIN
FOCUS/TRACKING COIL DRIVE,
SPINDLE/SLED MOTOR DRIVE
IC703
2
1
M
M
7
MUTE
FOCUS GAIN
UP SWITCH
Q705
FOCUS GAIN
UP SWITCH
Q704
16M BIT SD-RAM
IC702
ANTI-SHOCK
MEMORY CONTROLLER
DIGITAL SERVO
SIGNAL PROCESSOR
56 – 71
41 – 52
19 – 24, 27 – 32
2, 3, 5, 6, 8, 9, 11, 12, 39,
40, 42, 43, 45, 46, 48, 49
RCLK (O)
DQ00 – DQ15
DQ0 – DQ15
A00 (O) – A11 (O)
A0 – A11
CLK
35
RCKE (O)
CKE
34
WEX (O)
WE
15
CASX (O)
CAS
16
RASX (O)
RAS
17
37 38 55 54 53
16K SRAM
FOCUS GAIN
CONTROL SWITCH
Q703
21
TDOUT (O)
20
JUMPO (O)
23
SDOUT (O)
24
CLVOUT (O)
19
FDOUT (O)
91
XPLCK
88
DFDIN (I)
RESETX
33
RW (I)
30
MCK (I)
31
DIN (I)
32
DOUT (O)
53 C-DOUT (I)
54 C-DIN (O)
55 C-MCK (O)
62 C-RW (O)
64 C-RESETX (O)
61 C-BUSY (I)
52 C-SUBSYQ (I)
COMMAND
INTERFACE
D703
34
1BIT
D/A CONVERTER
80
LDACO
82
RDACO
CD-LOUT
RF AMP, FOCUS/TRACKING SERVO,
DIGITAL SIGNAL PROCESSOR,
DIGITAL SERVO SIGNAL PROCESSOR,
DIGITAL FILTER, D/A CONVERTER,
ANTI-SHOCK MEMORY CONTROLLER
IC701
(Page 18)
A
R-CH
X8 OVER
SAMPLIMG
DIGITAL FILTER
DIGITAL SERVO
FILTER
SERVO
SIGNAL
GENERATOR
XI (I)
XO (O)
X701
16.9344MHz
77
BUSY 35
SUBSYQ 29
76
MONI0
MONI1 90
89
ERROR
MONITOR
Q702
29
C-DOOR
S801
PUSH     OPEN/CLOSE
63 C-LIM SW (I)
When the optical pick-up
is inner position
ON :
S701
(LIMIT)
Page of 51
Display

Click on the first or last page to see other ZS-X1 service manuals if exist.