Sony ZS-R100CP Service Manual ▷ View online
ZS-R100CP
9
2-8. POWER BOARD
8
Remove six solders.
130 ± 5 mm
3
screw
(BV tapping B2.6)
1
connector
(CN901)
5
fiber washer
5
two fiber washers
9
power transformer (T901)
7
ferrite core (FC2)
6
tape
0
POWER board
POWER board
Let the wire pass below
the POWER board.
the POWER board.
Twist the wire around the ferrite core three times,
and fix it by a tape.
and fix it by a tape.
tape
POWER board
BATTERY board
:LUHVHWWLQJ
–&DELQHWUHDUEORFNIURQWVLGHYLHZ–
ferrite core
2
screw
(PWH tapping
B2.6)
B2.6)
3
three screws
(BV tapping B2.6)
4
Remove the POWER board block
in the direction of an arrow.
ZS-R100CP
10
2-9. CHASSIS (CENTER) SUB ASSY
Note 1: When setting wire of upper surface, refer to “2-16. WIRE SETTING” (page 15).
B
B
A
A
Insert is straight to the interior.
Insert is incline
flexible flat
cable
cable
flexible flat
cable
cable
connector
connector
OK
NG
Note 2: When you install the flexible
flat cable, please install them
correctly. There is a possibility
that this machine damages
when not correctly installing it.
3
connector
(CN307)
2
connector (CN907)
4
flexible flat cable (9 core)
(CN001)
7
flexible flat cable
(15 core) (CN602)
8
chassis (center) sub assy
1
flexible flat cable
(9 core) (CN602)
MAIN board
MAIN board
front side
tape
box (SP, L)
:LUHVHWWLQJ
–5HDUVLGHYLHZ–
–5HDUVLGHYLHZ–
5
screw
(BV tapping B2.6)
5
screw
(BV tapping B2.6)
5
screw
(BV tapping B2.6)
6
Remove the chassis
(center) sub assy in
the direction of
an
arrow.
ZS-R100CP
11
2-10. MAIN BOARD
Insert is straight to the interior.
Insert is incline
flexible flat
cable
cable
flexible flat
cable
cable
connector
connector
OK
NG
MAIN board
CD board
CD board
CD board
CD board
chassis (center)
chassis (center)
chassis (center)
chassis (center)
chassis (center)
:LUHVHWWLQJ
:LUHVHWWLQJ
:LUHVHWWLQJ
:LUHVHWWLQJ
Note: When you install the flexible
flat cable, please install them
correctly.There is a possibility
that this machine damages
when not correctly installing it.
1
flexible flat cable (25 core)
(CN501)
3
MAIN board
2
screw
(BV tapping B2.6)
2
screw
(BV tapping B2.6)
2
two screws
(BV tapping B2.6)
2
two screws
(BV tapping B2.6)
ZS-R100CP
12
2-11. BOX (R SP) SUB ASSY, BOX (L SP)
Note 1: When setting wire of upper surface, refer to “2-16. WIRE SETTING” (page 15).
TU board
tape
tape
panel (front) block
ferrite-rod antenna coil
(L11)
(L11)
ferrite-rod antenna coil (L11)
box (R SP) sub assy
:LUHVHWWLQJ
–5HDUVLGHYLHZ–
2
box (L SP)
2
box (R SP) sub assy
1
screw
(BV tapping B2.6)
1
screw
(BV tapping B2.6)
1
two screws
(BV tapping B2.6)
1
two screws
(BV tapping B2.6)
1
two screws
(BV tapping B2.6)
2-12. CHASSIS (NET) BLOCK
Insert is straight to the interior.
Insert is incline
flexible flat
cable
cable
flexible flat
cable
cable
connector
connector
OK
NG
Note: When you install the flexible
flat cable, please install them
correctly. There is a possibility
that this machine damages
when not correctly installing it.
– Rear side view –
1
flexible flat cable
(9 core) (CN610)
3
chassis (net) block
2
five screws
(BV tapping B2.6)
2
two screws
(BV tapping B2.6)
2
three screws
(BV tapping B2.6)