13
KEY  CHECK  MODE
Button check.
Procedure:
1.  While pressing the [MUTING] and the [INPUT MODE] but-
tons, press the [
?/1
] button to turn on the main power.
2.  The message “REST 11” appears.
 
Every pressing of any button other than the [
?/1
] counts down 
the buttons. The buttons which are already counted once are 
not counted again. When all buttons are pressed “REST 00” 
displayed.
SPDIF  UPDATE  MODE
User plays the CD that contains u-com/DSP data with CD/DVD 
player.
Update u-com/DSP etc. fi rmware from SPDIF input.
Connection:
CD/DVD
player
DIGITAL board
COAXIAL DVD IN jack (J2000)
set
Procedure:
Normal case
1.  While pressing  [DIMMER] button, press the [
?/1
] button to 
turn on the main power.
2.  The messages “UPDATE” and “PLAY DISC” are displayed 
alternately every one second.
 
After this step, all user operation is prohibited except power 
off. To cancel this mode, power off or AC power cord pull out 
is required.
3.  Connect CD player to COAXIAL DVD IN jack (J2000 on the 
DIGITAL board), and play update CD.
 
Update is started when DSP detect update signal. The message 
“UPDATING” is displayed blinks every one second.
 
From this step, all user operation is prohibited. Power off is 
also prohibited.
4.  While main u-com is being updated, fl uorescent indicator tube 
is blacked out.
5.  When update data error is detected or disc is not matched with 
target model, error messages “DISC ERROR” and “PLAY 
DISC” are displayed to restart playing valid CD.
 When 
fl ash writing error is happened, error messages “UP-
DATE ERR” and “PLAY DISC” are displayed to restart play-
ing CD.
6. When all update is fi nished, set is reboot automatically. After 
reboot, complete message “COMPLETE” is displayed (dis-
played continuously until any user operation).
Procedure:
After update is abnormal exit, and set is power on again
1.  Enter update mode automatically after power on.
2.  The messages “UPDATE” and “PLAY DISC” are displayed 
alternately every one second.
 
From this step, all user operation is prohibited. Power off is 
also prohibited.
 
If main u-com was failed to update, nothing is displayed.
3.  Connect CD player to COAXIAL DVD IN jack (J2000 on the 
DIGITAL board), and play update CD.
 
Update is started when DSP detect update signal. From this, 
same as normal case.
VERSION  CHECK
Function that displays the version number to check whether SPDIF 
update is necessary or not.
Procedure:
1.  While pressing  [MUTING] button, press the [
?/1
] button to 
turn on the main power.
2.  The message “VER X.XXX” is displayed. “X.XXX” is calcu-
lated by adding all fi rmware version.
 Example:
 
(MAIN ver. + DSP ver. + HDMI ver. + FARO ver. + 6)/10 = 
Displayed version
 
MAIN = 1.02, DSP = 1.01, HDMI = 1.00, FARO = 1.03
 
 
(1.02 + 1.01 + 1.00 + 1.03 + 6)/10 = 1.006
 
1.006 = X.XXX
SPDIF  UPDATE  CHECK
Function that checks hardware error for SPDIF update.
This test takes about 15 seconds.
Procedure:
1.  While pressing  [DIMMER] and [2CH/A.DIRECT] buttons, 
press the [
?/1
] button to turn on the main power.
2.  The message “TESTING” is displayed and LED (MULTI 
CHANNEL DECODING indicator) is blinking.
3.  When abnormality is not found, the message disappears and 
LED is light up.
4.  Communication error between main microcomputer and DSP, 
the messages “UART” and “ERROR” are displayed and LED 
is blinking in fast speed.
  Communication error between HDMI microcomputer and 
DSP, the messages “HDMI” and “ERROR” are displayed and 
LED is blinking in fast speed.
 
Communication error between video processor and DSP, the 
messages “VIDEO” and “ERROR” are displayed and LED is 
blinking in fast speed.
 
Unknown error, the messages “UNKNOWN” and “ERROR” 
are displayed and LED is blinking in fast speed.
5.  To release from this mode, AC power cord pull out.
Note: SPDIF UPDATE MODE, VERSION CHECK and SPDIF UPDATE 
CHECK are supported with DSP version 1.02 or later.
Ver. 1.1
STR-DN1000
14
SPECIAL  MENU  MODE
Procedure:
1.  Press the [
?/1
] button to turn on the main power, then while pressing the [INPUT SELECTOR +] button, press the [A.F.D.], [2CH/A. 
DIRECT], [MUSIC], [MOVIE] button in order, the message “SPECIALIZE” appears.
2.  Press the [
M
]/[
m
] buttons on the remote commander, the message “< SPECIAL>” appears.
3.  Press the [
,
] button on the remote commander, the item is appears.
4.  Each time the [
M
]/[
m
] buttons on the remote commander is pressed, the item is switched in order as follows.
 
Some items can change the content. Display the cursor by pressing the [
,
] button on the remote commander, and changing the content 
by pressing the [
M
]/[
m
] buttons on the remote commander, and fi x the content by pressing the [
<
] button on the remote commander 
when you want to change the content of the item.
5.  To release from this mode, while pressing the [INPUT SELECTOR +] button, press the [A.F.D.], [2CH/A. DIRECT], [MUSIC], 
[MOVIE] button in order again, the message “OFF” appears.
Items
Display
Remark
Model/Destination change
MODEL
When [,] button on the remote commander is pressed, the message “N1 
** XX” is appears
**: Destination
XX: fx or at
Main micom version display
N1 ** MX.XX
X.XX: System controller software version
**: Destination
Farouja version display
F.Ver X.XX
X.XX: Farouja software version
CGROM micom version display
G.Ver X.XX
X.XX: CGROM controller software version
HDMI micom version display
H.Ver X.XX
X.XX: HDMI controller software version
DSP serial fl ash version display
S.Ver X.XX
X.XX: Serial fl ash software version
FLI update
FLI UPDATE
When [,] button on the remote commander is pressed, the message “ON” 
or “OFF” is appears
Switching with [M]/[m] buttons on the remote commander
HD update
HD UPDATE
When [,] button on the remote commander is pressed, the message “ON” 
or “OFF” is appears
Switching with [M]/[m] buttons on the remote commander
HDCP key read
HDCP KEY
When [,] button on the remote commander is pressed, the message “ON” 
or “OFF” is appears
Switching with [M]/[m] buttons on the remote commander
Video Factroy
V. FACTORY
Not used for the servicing
Auto cal mic test
SP OUT
When [,] button on the remote commander is pressed, the message 
“SOURCE” or “MIC” is appears
Switching with [M]/[m] buttons on the remote commander
SOURCE: normal mode, MIC: mode that output audio from mic input
FL display fonts test
FL FONT
When [,] button on the remote commander is pressed, the message 
“0X**=X” is appears
**: 20 to FF, X: character
Switching with [M]/[m] buttons on the remote commander
DSP halt
DSP HALT
When [,] button on the remote commander is pressed, the message “ON” 
or “OFF” is appears
Switching with [M]/[m] buttons on the remote commander
Super reset
RESET
Not used for the servicing
When EEPROM initialization is required, perform the “memory clearing 
mode”
RAM watch menu
RAM WATCH
When [,] button on the remote commander is pressed, the message 
“XXXXXXXXXX” is appears
XXXXXXXXXX: Various internal RAM 
Switching with [M]/[m] buttons on the remote commander
IO WATCH
IO WATCH
When [,] button on the remote commander is pressed, the message “P*** 
XXXXX” is appears
***: IO pin address, XXXXX: status
EEPROM debug
EEPROM
When [,] button on the remote commander is pressed, the message “****   
XX” is appears
****: EEPROM address, XX: EEPROM data
Switching with [M]/[m] buttons on the remote commander
Protector on/off
PROTECTOR
When [,] button on the remote commander is pressed, the message “ON” 
or “OFF” is appears
Switching with [M]/[m] buttons on the remote commander
Audio swap
SWAP MODE
When [,] button on the remote commander is pressed, the message 
“XXXXXXXXXX” is appears
XXXXXXXXXX: audio swap mode
Switching with [M]/[m] buttons on the remote commander
Ver. 1.1
STR-DN1000
15
Items
Display
Remark
Thermal watch
THERMAL
When [
,
] button on the remote commander is pressed, the message 
“TEMP CH1” or “TEMP CH2” is appears (Switching with [
M
]/[
m
] but-
tons on the remote commander) 
To next, When [
,
] button on the remote commander is pressed, the 
message “DHex: XXXX”, “Volt: XXXX” or “Temp: XXXX” is appears 
(Switching with [
M
]/[
m
] buttons on the remote commander) 
DHex: software AD reading (Hexadecimal value) 
Volt: analog voltage value (volt) 
Temp: temperature (degree celsius)
Limiter watch
LIMITER
When [
,
] button on the remote commander is pressed, the message 
“DHex: XXXX” or “Volt: XXXX” is appears (Switching with [
M
]/[
m
buttons on the remote commander) 
DHex: software AD reading (Hexadecimal value) 
Volt: analog voltage value (volt)
Power Control
POWER CTRL
When [
,
] button on the remote commander is pressed, the message 
“SAFETY” or “BRIDGE” is appears
Trigger Level
TRIG LEVEL
When [
,
] button on the remote commander is pressed, the message “***: 
xxxx” is appears 
***: Trigger level, xxxx: Level setting
EVOL data watch
EVOL DATA
When [
,
] button on the remote commander is pressed, the message “** 
XXXX” is appears 
**: speaker channel, XXXX: EVOL data 
Switching with [
M
]/[
m
] buttons on the remote commander
DAC mute watch
DAC MUTE
When [
,
] button on the remote commander is pressed, the message “U 
XXXXXXXX” or “L XXXXXXXX” is appears (Switching with [
M
]/[
m
buttons on the remote commander) 
XXXXXXXX: Display of module information to demand muting in sys-
tem controller
Volume value display (FL/FR)
L****RXXXX
****: Front L-ch volume value, XXXX: Front R-ch volume value (for design 
evaluation)
Volume value display (SL/SR)
S****SXXXX
****: Surround L-ch volume value, XXXX: Surround R-ch volume value (for 
design evaluation)
Volume value display (CT/SW)
C****WXXXX
****: Center volume value, XXXX: Sub woofer volume value (for design 
evaluation)
Volume value display 
(SBL/SBR)
B****BXXXX
****: Surround back L-ch volume value, XXXX: Surround  back R-ch volume 
value (for design evaluation)
DAC mute information disclosure 1
U XXXXXXXX
Display of module information to demand muting in system controller (for 
design evaluation)
DAC mute information disclosure 2
L XXXXXXXX
Display of module information to demand muting in system controller (for 
design evaluation)
Faroudja check mode
FCP TEST
When [,] button on the remote commander is pressed, the message “FCP 
XXX” is appears 
XXX: ON or OFF
FL display duty change
DUTY
When [,] button on the remote commander is pressed, the message “XXX” 
is appears
XXX: Duty value of FL display (1% to 100%) (for design evaluation)
Increase and decrease of duty value with [M]/[m] buttons on the remote com-
mander
Language
LANGUAGE
-
Ver. 1.1
STR-DN1000
16
SECTION  4
ELECTRICAL  CHECK
FM  AUTO  STOP  CHECK
signal 
generator
set
Procedure:
1.  Turn on the set.
2.  Input the following signal from signal generator to FM antenna 
input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation 
: 75 kHz
Modulation 
: 1 kHz
ANT input 
: 35 dBu (EMF)
Note: Use 75 ohm coaxial cable to connect signal generator and the set. 
You cannot use video cable for checking.
 
  Use signal generator whose output impedance is 75 ohm.
3.  Set to FM tuner function and scan the input FM signal with 
automatic scanning.
4. Confi rm that input frequency of A, B and C are detected and 
automatic scanning stops.
When the station signal is received in good condition, automatic 
scanning stops.
Page of 105