13
6. Press the H button.
7. Check that the waveform on oscilloscope is clear, and the level
and jitter of waveform satisfy the specifications.
8. After checking, press the 
x
 button.
9. Repeat steps 3 through 8 for respective discs.
10. Press the 
!
 button to turn the power off.
Specified Value:
Disc
A
Jitter (displayed value)
SATD-S2
1.25 to 1.65 Vp-p
20 (Hex) or less
TCD-784
1.3 to 1.7 Vp-p
15 (Hex) or less
bbb
              CD1
             
Discchk
XX
XX
Disc type (refer to Disc check list (page 11))
6. Press the - button and 1 button, the - button and 2 but-
ton, and the - button and 3 button on the remote commander
successively to execute the focus search.
7. Check that the waveform on oscilloscope is within the level
A and B specifications.
8. After checking, press the  
x
  button.
9. Repeat steps 3 through 8 for respective discs.
10. Press the ! button to turn the power off.
Specified Value:
Disc
A
B
SATD-S2
1.5 to 2.3Vp-p
- 0.1 to +0.1V
TCD-784
S Curve Check
Connection:
RF Level Check
Connection:
MAIN board
TP524 (FE)
TP501 (VC)
+
oscilloscope
(normal mode)
Procedure:
1. Connect an oscilloscope to the TP524(FE) and TP501(VC) on
the MAIN board.
2. Set the Adjustment-1 Mode. (See 5-2. Adjustment-1 Mode in
SECTION 5 (page 11))
3. Set a disc (SATD-S2 or TCD-784).
4. Press the 3 button and - button on the remote commander
to make the disc type checked.
Note:
If the disc check was made in the Adjustment-1 Mode, pressing
another button immediately after pressing the 3 and - buttons
on the remote commander could cause the microcomputer to run
out of control, thus requiring extreme care.
5. Confirm that the disc was checked.
A
B
S curve waveform
VC
MAIN board
TP503 (RF)
TP501 (VC)
+
oscilloscope
(auto mode)
Procedure:
1. Connect an oscilloscope to the TP503(RF) and TP501(VC) on
the MAIN board.
2. Set the Adjustment-1 Mode. (See 5-2. Adjustment-1 Mode in
SECTION 5 (page 11))
3. Set a disc (SATD-S2 or TCD-784).
4. Press the 3 button and - button on the remote commander
to make the disc type checked.
Note:
If the disc check was made in the Adjustment-1 Mode, pressing
another button immediately after pressing the 3 and - buttons
on the remote commander could cause the microcomputer to run
out of control, thus requiring extreme care.
5. Confirm that the disc was checked.
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
RF signal waveform
A
bbb
              CD1
+ 00
00
~00
09
Jitter value
(HEX)
not fixed
Adjustment Location : See page16.
Adjustment Location : See page16.
bbb
              CD1
             
Discchk
XX
XX
Disc type (refer to Disc check list (page 11))
Note:
 For easier observation of this waveform, extend the sweep time
and raise the brightness.
Note: 
Clear RF waveform refers to the waveform where 
 shapes should
be distinctively observed in the center.
Display example:
14
Optical Pick-up Height Adjustment
Connection:
MAIN board
TP702 (MNT4)
TP703 (MNT5)
TP521 (GND)
+
+
oscilloscope
(normal mode)
(CH1)
(CH2)
CLV Jitter Check
Connection:
A
CLV jitter waveform
MAIN board
TP515 (PI)
TP511 (FOUT)
TP501 (VC)
+
+
storage
oscilloscope
(normal mode)
(CH2)
(CH1)
Procedure:
1. Connect an oscilloscope to the TP515(PI)(CH1),
TP511(FOUT) (CH2) and TP501(VC) on the MAIN board.
2. Set the Adjustment-1 Mode. (See 5-2. Adjustment-1 Mode in
SECTION 5 (page 11))
3. Set a disc (SATD-S1).
4. Press the [FILTER] button to set the Focus Search mode.
5. Loosen the OP height adjusting screw 1, and while shifting
the Holder (R2), adjust the height so that the waveform on
oscilloscope satisfies the specified value.
6. Press the [FILTER] button to set the Play mode.
7. Adjust the TAN skew 2 so as to attain most preferable jitter
value on the display.
8. Press the [FILTER] button to set the Focus Search mode.
9. Check that the B value of waveform on oscilloscope satisfies
the specification.
10. Repeat steps 5 through 9.
11. Lock the OP height adjusting screw 1 when adjustment fin-
ished.
12. Press the 
x
 button.
13. Press the 
!
 button to turn the power off.
Specified Value: B is more than 0, and less than A/3
A
B
VC
VC
PI
FOUT
Procedure:
1. Connect an oscilloscope to the TP702(MNT4)(CH1),
TP703(MNT5)(CH2) and TP521(GND) on the MAIN board.
2. Set the Adjustment-2 Mode. (See 5-3. Adjustment-2 Mode in
SECTION 5 (page 11))
3. Set a disc (SATD-S2 or TCD-784).
4. Press the 
H
 button.
5. Move the sled to the middle track.
• Sled middle track
SATD-S2:TN05
TCD-784:TN05
6. Check that the A value of waveform on oscilloscope satisfies
the specification.
7. After checking, press the 
x
 button.
8. Repeat steps 3 through 7 for respective discs.
9. Press the 
!
 button to turn the power off.
Specified Value:
Disc
A
SATD-S2
55 µsec or less
TCD-784
*1
*1: Normal-trigger the oscilloscope using FOUT on CH2.
2
TAN skew
1
OP height
adjusting screw
Holder (R2)
Adjustment Location : See page16.
Adjustment Location : See page16.
15
Overall Adjustment
Procedure:
1. Set the Adjustment-1 Mode. (See 5-2. Adjustment-1 Mode in
SECTION 5 (page 11))
2. Press the 6 button and 2 button, then the 9 button on the
remote commander (to initialize data).
3. Set a disc (TCD-784).
4. Press the 6 button and - button, then the 5 button on the
remote commander. (Adjustment will take about 2 minutes.)
5. Remove the disc when "CD END" is displayed.
6. Set a disc (SATD-S2).
7. Press the 6 button and - button, then the 5 button on the
remote commander. (Adjustment will take about 1 minute 30
seconds.)
8. Remove the disc when "SL END" is displayed.
9. Set a disc (SATD-S3).
10. Press the 6 button and - button, then the 5 button on the
remote commander. (Adjustment will take about 1 minute.)
11. Remove the disc when "DL END" is displayed.
Note:
 If an error is displayed during the adjustment so far, press again the
6 button and - button on the remote commander to execute re-
adjustment.
12. Press the 6 button and 1 button on the remote commander.
13. As the number and adjusted value are displayed, make sure
that it is within the threshold.
14. Press the 1 button on the remote commander to proceed to
the next item. (To return to the previous item, press the 2
button.)
15. Repeat steps 13 and 14.
16. After checking items up to No.43, press the 
!
 button to turn
the power off.
Thresholds for Overall Adjustment
No.
Description
U limit
L limit
00
PI Level SL
0
4
01
PI Level DL
3
7
02
PI Offset CD
15D
2A3
03
PI Offset SL
15D
2A3
04
PI Offset DL
15D
2A3
05
PI Offset Disc Check
100
2FF
06
Traverse Offset CD
07
Traverse Offset SL
08
Traverse Offset DL
09
Traverse Gain CD
10
Traverse Gain SL
11
Traverse Gain DL
12
For PI Level Disc Check
0
2
13
PI Reflectance SL
2D28
7333
14
PI Reflectance DL
936
4083
15
Surface Reflect to CD Layer Distance
82
16
Surface Reflect to DSD Layer Distance
41
82
17
Low Push-pull for Disc Check
4FDF
9999
18
High T Bal for Disc Check
0000
47AE
19
FE Offset CD
20
FE Offset SL
21
FE Offset DL
22
Focus Bias CD
E0
20
23
Focus Bias SL
E0
20
24
Focus Bias DL0
E0
20
25
AGC Focus Gain CD
1500
3000
26
AGC Focus Gain DL
0851
1A00
27
AGC Focus Gain SL
0C28
2500
28
AGC Tracking Gain CD
1A00
3C00
29
AGC Tracking Gain SL
1100
2500
30
AGC Tracking Gain DL
1400
2700
31
RF Loop Filter Offset CD
F6
0A
32
RF Loop Filter Offset DSD
F6
0A
33
Tilt Disordered Point CD +side
34
Tilt Disordered Point CD -side
35
Tilt Disordered Point SL +side
36
Tilt Disordered Point SL -side
37
Tilt Disordered Point DL +side
38
Tilt Disordered Point DL -side/
39
Tilt Offset CD
F0
10
40
Tilt Offset SL
F0
10
41
Tilt Offset DL
F0
10
42
Focus Balance SL
43
Focus Balance DL
Note:
1. No threshold specified for      items.
2. All thresholds are displayed in Hex.
16
Adjustment Location:
– MAIN Board (Component Side) –
TP511
(FOUT)
TP515
(PI)
TP524
(FE)
TP501
(VC)
TP516
(TE)
TP521
(GND)
TP503
(RF)
TP703
(MNT5)
TP702
(MNT4)
Page of 78