DOWNLOAD Sony MHC-V5 (serv.man3) Service Manual ↓ Size: 2.32 MB | Pages: 29 in PDF or view online for FREE

Model
MHC-V5 (serv.man3)
Pages
29
Size
2.32 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / REPAIR MANUAL
File
mhc-v5-sm3.pdf
Date

Sony MHC-V5 (serv.man3) Service Manual ▷ View online

1-3-1. Party chain 
With Party chain function, all the connected systems can output the source system’s sound without sound delay. 
Source sound system is called “Party Host”.  Other connected system are “Party Guests”. 
 
If all systems can support Party chain, please connect them with loop connection as below (A).  
If one model doesn’t support Party chain, please connect with linear connection as below (B).  
Loop connection 
Linear connection 
This system 
doesn’t support 
Party chain 
function.  
P: Party Chain is  
            supported. 
Party Host 
Party Guest 
Party Guest 
Party Guest 
Party Host 
1-3-2. Party chain 
If all systems can support Party chain, Party Host can be changed automatically by setting Party chain with another set. 
 
1. When “Party chain” is started with panel key input, the system become “Party host” and starts to output 
DC 1V as Party host 
to AUDIO OUT.  
    By detecting this DC voltage, the connected  system changes to “Party Guest” mode and starts to output 
DC2V as Party guest
    This sound signal with DC voltage sets all the systems to Party chain mode.  (1-3 in the figure below) 
    “Party Guest” ignores any command except volume and sound field and flashes error message of “PARTY CHAIN” on display.  
Loop connection 
1. Start Party chain 
    and output DC1V 
    as Party Host 
 
6. Detecting DC1V 
⇒ Party Guest 
⇒ Output DC2V 
        as Party Guest 
2.  Detecting DC1V 
⇒ Party Guest 
⇒ Output DC2V  
       as Party Guest 
 
4. Start Party chain 
    and output DC1V 
    as Party Host 
3. Detecting DC2V 
⇒ Party Guest 
⇒ Output DC2V 
        as Party Guest 
 
5. Detecting DC1V 
⇒ Party Guest 
⇒ Pass through DC1V 
2. When one “Party Guest” is set to “Party host” with panel 
key input, the system start to output 
DC 1V as Party host.  
“Party Guest” passes through the input signal to output 
terminal basically. And, when the original “Party Host” detects 
this DC1V input, the system changes to  “Party Guest”. Then, 
the system starts to output 
DC2V as Party Guest. 
By this operation, “Party Host” can be changed. 
 
“Party Guest” passes through the input signal to output 
terminal directly to prevent sound delay. 
“Party Host” delays the output signal to another sets to 
prevent sound delay occurs between “Party Host” and “Party 
Guest”. 
 
Therefore, the system which includes Party chain must be 
Party Host. And, Party host cannot select AUDIO IN function 
to prevent loop oscillation. 
 
When Party chain ends, “Party host” stops DC voltage output. 
With this connection, please be noted AUDIO IN is not used. 
(Ex. DVP sound input) 
1-3-3. Party chain 
If you connect a system which doesn’t support Party chain function, the system must be connected to the end of linear connection. 
Refer to right bottom figure.  
 
One way connection 
Party Guest 
(only) 
Party Guest 
Party Host 
P: Party Chain is  
            supported. 
If Second system starts playback in the right figure,   
the Second and Last system output Second system 
sound. But, First system continue to output First 
system’s sound.  
This is a limitation to connect the systems with linear 
connection. 
 
If the system doesn’t support Party chain and it is 
“Party Guest, the sound delay doesn’t occur basically. 
 
If the system which doesn’t support Part chain is used 
as “Party Host”, sound delay may occurs between 
“Party Host” and “Party Guest”. 
This system 
doesn’t support 
Party chain 
function.  
PROTECT 
E05
: AMP temperature error 
=> Remove obstacle around ventilator at side panel. 
=> Move the set to cool place and turn off for a while. 
=> Confirm booster’s heat sink condition on AMP board. 
1-4. Error message 
PROTECT XX : Over temperature detection 
                                             or Amplifier circuit emergency 
OVER CURRENT: 
USB
 current detection  
                                circuit problem 
DEVICE ERROR : 
USB
 data detection error 
FATAL ERROR   : 
USB
 data communication  
                               error 
 
=> Confirm USB device and the data format. 
      Try to connect another USB device and 
      change the connecter (A/B) 
 LOCKED 
: Eject protect mode for 
                          demonstration in shop 
 
=> Refer to Service manual and  
     release the mode. 
PROTECT 
E04
: DC voltage detection to Speaker output 
=> Decrease playback level for speaker and play again. 
=> Measure speaker resistance to check damage. 
      (In case of speaker coil is shorted,  
PROTECT 
E03
: AMP voltage error 
=> AMP operation voltage is not detected.  
     Open the set and check voltage line. 
PROTECT 
E01
: DAMP over current error. 
=> AMP IC detects over current in signal line. 
     Playback signal is too high or AMP circuit was damage. 
PROTECT 
E04:
 DC fan drive voltage error. 
=> Check the existence of obstacle around FAN on the  
     back panel. (Dust, etc) 