Page 36 
#PANEL test 
   You can check FL display, LED and key input in this test mode.  
 
Page 37 
#SERVO CHECK 
  You can disc playability with this test mode instantly. 
  By using good condition disc, you can confirm the playability of the set. 
  If the set is good condition, you can check the disc playability with this mode. 
 
  Only the most inner part condition of the disc can be checked in this mode. 
  This mode doesn’t support check of the disc condition of all surface. 
 
 (Scratch, etc.)  
2-5. MHC-V5 Test mode 
Most inner part 
Scratch 
3-1. Circuit operation (Standby mode of Power saving mode) 
14 
1: AC voltage input 
4: System controller  
    boots up. 
2: Power supply board 
    outputs 13.5V for 
    SYSCON booting. 
MICOM 
  + DSP 
Page 41 
3: EVER+3.3V outputs 
    from D/D Converter 
    (IC002) 
Repair tips: 
Original standby mode is 
“demonstration” mode. 
In this mode, FL tube and  
Speaker LED operates for 
demonstration. 
By pressing DISPLAY button 
while the set turn off, the  
mode can be shifted to 
“Power saving” and “clock”. 
Repair tips: 
EVER+3.3V output can be 
checked at ARAGON board  
connecter terminal. 
(CN304 pin1 and 2) 
Repair tips: 
13.5V output can be checked 
 at connecter terminal 
(CN001 pin1 and 3) 
15 
3-2. Circuit operation (System control) 
5: System controller (IC101) 
    boots up and start to read  
    operation firmware from  
    Flash ROM (iC106). 
Page 39 
6: System controller reads 
    back up data from EEPROM. 
    (Last function, volume,  
      Preset tuner, etc.) 
    Back up data is recorded 
     only when the set turn off  
     with power key input. 
Note: 
The backup data is written only 
when the set turns off with  
power button. If AC cord is pulled 
off, the backup data is not saved. 
3-3. Circuit operation (Wakeup operation) 
16 
8: System controller  
    outputs several 
    Power Control 
    signals. 
7: Wake up key inputs 
    to System controller. 
Page 41 
12:LED driver(IC2002) 
     turns on each LEDs. 
10: Switching Regulator 
    starts to output 
    additional voltages.  
    (AMP circuit, etc.) 
9: Several switches  
    turn on and output 
    voltages. 
    (FL tube, etc.) 
11: FL tube turns on 
Page of 29