TABLE OF CONTENTS
1. SERVICING NOTE
.......................................................... 6
2. GENERAL
........................................................................ 13
3. DISASSEMBLY
3-1. Case ..................................................................................... 14
3-2. Front Panel Assy ................................................................. 14
3-3. MD Mechanism Deck (MDM-5A) ..................................... 15
3-4. Main Board ......................................................................... 15
3-5. Slider (Cam) ........................................................................ 16
3-6. BD Board ............................................................................ 16
3-7. Over Write Head ................................................................. 17
3-8. Optical Pick-up (KMS-260A/J1N) ..................................... 17
3-9. Spindle Motor, Sled Motor ................................................. 17
3-2. Front Panel Assy ................................................................. 14
3-3. MD Mechanism Deck (MDM-5A) ..................................... 15
3-4. Main Board ......................................................................... 15
3-5. Slider (Cam) ........................................................................ 16
3-6. BD Board ............................................................................ 16
3-7. Over Write Head ................................................................. 17
3-8. Optical Pick-up (KMS-260A/J1N) ..................................... 17
3-9. Spindle Motor, Sled Motor ................................................. 17
4. TEST MODE
..................................................................... 18
5. ELECTRICAL ADJUSTMENTS
............................... 22
6. DIAGRAMS
6-1. Block Diagrams
• BD Section ....................................................................... 32
• Main Section .................................................................... 33
• Main Section .................................................................... 33
6-2. Printed Wiring Board – BD Section – ................................. 34
6-3. Schematic Diagram – BD (1/2) Section – ........................... 35
6-4. Schematic Diagram – BD (2/2) Section – ........................... 36
6-5. Schematic Diagram – Main (1/2) Section – ........................ 37
6-6. Schematic Diagram – Main (2/2) Section – ........................ 38
6-7. Printed Wiring Board – Main Section – .............................. 39
6-8. Printed Wiring Board – Panel Section – ............................. 40
6-9. Schematic Diagram – Panel Section – ................................ 41
6-10. Schematic Diagram – BD Switch Section – .................... 42
6-11. Printed Wiring Board – BD Switch Section – .................. 42
6-12. IC Block Diagrams ........................................................... 42
6-13. IC Pin Functions ............................................................... 45
6-3. Schematic Diagram – BD (1/2) Section – ........................... 35
6-4. Schematic Diagram – BD (2/2) Section – ........................... 36
6-5. Schematic Diagram – Main (1/2) Section – ........................ 37
6-6. Schematic Diagram – Main (2/2) Section – ........................ 38
6-7. Printed Wiring Board – Main Section – .............................. 39
6-8. Printed Wiring Board – Panel Section – ............................. 40
6-9. Schematic Diagram – Panel Section – ................................ 41
6-10. Schematic Diagram – BD Switch Section – .................... 42
6-11. Printed Wiring Board – BD Switch Section – .................. 42
6-12. IC Block Diagrams ........................................................... 42
6-13. IC Pin Functions ............................................................... 45
7. EXPLODED VIEWS
7-1. Case and Front Panel Section ............................................. 50
7-2. Mechanism Deck Section (MDM-5A) ................................ 51
7-3. Base Unit Section (MBU-5A) ............................................. 52
7-2. Mechanism Deck Section (MDM-5A) ................................ 51
7-3. Base Unit Section (MBU-5A) ............................................. 52
8. ELECTRICAL PARTS LIST
........................................ 53
MODEL IDENTIFICATION
— BACK PANEL —
• Abbreviation
AED
: North European model
MY
: Malaysia model
SP
: Singapore model
HK
: Hong kong model
KR
: Korea model
MODEL
AEP, UK, AED models
HK, MY, SP models
KR model
PARTS No.
4-229-665-0
s
4-229-665-2
s
4-229-665-3
s
Parts No.
6
SECTION 1
SERVICING NOTE
This unit cannot be repaired by itself.
When repairing, connect the whole system except for the speaker.
When repairing, connect the whole system except for the speaker.
CD Text Display
• This unit displays CD text.
Text is displayed for the first 50 track only and will not be displayed from the 51st track onwards. Do not suspect a fault in this case.
In some cases, some special characters will not be displayed and may be replaced by other characters. Do not suspect a fault in this case.
In some cases, some special characters will not be displayed and may be replaced by other characters. Do not suspect a fault in this case.
Cold Reset
• The cold reset clears all data including preset data stored in the RAM to initial conditions. Execute this mode when returning the set to the
customer.
Procedure :
1. When the power ON, press the ?/1 button (TA) while pressing the TUNING MODE button (ST) and ML buttons (CD) together.
2. “COLD RESET” is displayed on the fluorescent indicator tube and reset is executed.
1. When the power ON, press the ?/1 button (TA) while pressing the TUNING MODE button (ST) and ML buttons (CD) together.
2. “COLD RESET” is displayed on the fluorescent indicator tube and reset is executed.
Hot Reset
• This mode reset the preset data kept in the memory. The hot reset mode functions same as if the power cord is plugged in and out.
Procedure :
1. When the power ON, press the ?/1 button (TA) while pressing the TUNING MODE button (ST) and lm buttons (CD) together.
2. Turn off the unit and reset is executed.
1. When the power ON, press the ?/1 button (TA) while pressing the TUNING MODE button (ST) and lm buttons (CD) together.
2. Turn off the unit and reset is executed.
GC Test Mode
Procedure :
1. When the power ON, press the ?/1 button (TA) while pressing the TUNING MODE button (ST) and PLAY MODE buttons (CD)
1. When the power ON, press the ?/1 button (TA) while pressing the TUNING MODE button (ST) and PLAY MODE buttons (CD)
together.
2. LCD are all turned on.
3. Press TUNING MODE button (ST) to enter the model destination indecation mode. “SP55 CE2” or “SP55 ASIA2” appears.
4.
3. Press TUNING MODE button (ST) to enter the model destination indecation mode. “SP55 CE2” or “SP55 ASIA2” appears.
4.
Every pressing of TUNING MODE button (ST) changes the display in the following order.
MC Version
MC Version
t CD Version t ST Version t TC Version t TA Version t TM Version t model destination display.
5.
Press DISPLAY button (ST) and the date appears as “ 00615a ”
Every pressing of DISPLAY button (ST) changes the display in the Version display and model destination display.
Every pressing of DISPLAY button (ST) changes the display in the Version display and model destination display.
6. Press TUNER/BAND button (ST) to enter the key check mode.
7. In the key check mode, the fluorescent indicator tube displays “Key 0 Vol 0”. Each time a button is pressed, “Key” value increases.
7. In the key check mode, the fluorescent indicator tube displays “Key 0 Vol 0”. Each time a button is pressed, “Key” value increases.
However, once a button is pressed, it is no longer taken into account.
“Vol” Value increases like “1, 2, 3 ...” if rotating VOLUME knob (TA) in the clockwise direction, or decreases like “0, 9, 8 ...” if rotating
in the counterclockwise diretion.
“Vol” Value increases like “1, 2, 3 ...” if rotating VOLUME knob (TA) in the clockwise direction, or decreases like “0, 9, 8 ...” if rotating
in the counterclockwise diretion.
8. To exit from this mode, disconnect the power cord.
7
JIG FOR CHECKING BD BOARD WAVEFORM
The special jig (J-2501-149-A) is useful for checking the waveform of the BD board. The names of terminals and the checking items to be
performed are shown as follows.
performed are shown as follows.
GND : Ground
I+3V : For measuring IOP (Check the deterioration of the optical pick-up laser)
IOP : For measuring IOP (Check the deterioration of the optical pick-up laser)
TEO : TRK error signal (Traverse adjustment)
VC
I+3V : For measuring IOP (Check the deterioration of the optical pick-up laser)
IOP : For measuring IOP (Check the deterioration of the optical pick-up laser)
TEO : TRK error signal (Traverse adjustment)
VC
: Reference level for checking the signal
RF
: RF signal (Check jitter)
RF
VC
TEO
VC
TEO
For
MDM-3
MDM-3
For
MDM-5A
MDM-5A
IOP
I-3V
I-3V
VC
RF
TEO
IOP
I+3V
GND
RF
TEO
IOP
I+3V
GND
VC
RF
TEO
IOP
I+3V
GND
1
5
1
6
CN110
RF
5P connector
6P connector
VC
TEO
IOP
I+3V
GND
Mechanism deck
8
IOP DATA RECORDING AND DISPLAY WHEN OPTICAL PICK-UP AND NON-VOLATILE MEMORY (IC171 OF
BD BOARD) ARE REPLACED
BD BOARD) ARE REPLACED
The IOP value labeled on the optical pick-up can be recorded in the non-volatile memory. By recording the value, it will eliminate the need
to look at the value on the label of the optical pick-up. When replacing the optical pick-up or non-volatile memory (IC171 of BD board),
record the IOP value on the optical pick-up according to the following procedure.
to look at the value on the label of the optical pick-up. When replacing the optical pick-up or non-volatile memory (IC171 of BD board),
record the IOP value on the optical pick-up according to the following procedure.
Record Precedure:
1. When the power OFF (STANDBY), press the ?/1 button (TA) while pressing the s button (MD) and ENTER/YES button (MD)
1. When the power OFF (STANDBY), press the ?/1 button (TA) while pressing the s button (MD) and ENTER/YES button (MD)
together.
2. Press the MENU/NO button (MD), and when “Check” is displayed.
3. Rotate the l L knob (MD) to display “MD [Service]”, and press the ENTER/YES button (MD).
4. Rotate the l L knob (MD) to display “MD lop Write”, and press the ENTER/YES button (MD).
5. The display becomes “MD Ref=@@@.@” (@ is an arbitrary number) and the numbers which can be changed will blink.
6. Input the IOP value written on the optical pick-up.
3. Rotate the l L knob (MD) to display “MD [Service]”, and press the ENTER/YES button (MD).
4. Rotate the l L knob (MD) to display “MD lop Write”, and press the ENTER/YES button (MD).
5. The display becomes “MD Ref=@@@.@” (@ is an arbitrary number) and the numbers which can be changed will blink.
6. Input the IOP value written on the optical pick-up.
To select the number : Press the MENU/NO button (MD), and when “Check” is displayed.
To select the digit
To select the digit
: Press the CD SYNC REC button (MD).
7. When the ENTER/YES button (MD) is pressed, the display becomes “MD Measu=@@@.@” (@ is an arbitrary number).
8. As the adjustment results are recorded for the 6 value. Leave it as it is and press the ENTER/YES button (MD).
9. “MD Complete!” will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become
8. As the adjustment results are recorded for the 6 value. Leave it as it is and press the ENTER/YES button (MD).
9. “MD Complete!” will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become
“MD Iop Write”.
10. Press the ?/1 button (TA) to complete.
Display Precedure:
1. When the power OFF (STANDBY), press the ?/1 button (TA) while pressing the s button (MD) and ENTER/YES button (MD)
1. When the power OFF (STANDBY), press the ?/1 button (TA) while pressing the s button (MD) and ENTER/YES button (MD)
together.
2. Press the MENU/NO button (MD), and when “Check” is displayed.
3. Rotate the l L knob (MD) to display “MD [Service]”, and press the ENTER/YES button (MD).
4. Rotate the l L knob (MD) to display “MD lop Read”.
5. “MD @@.@/##.#” is displayed and the recorded contents are displayed.
3. Rotate the l L knob (MD) to display “MD [Service]”, and press the ENTER/YES button (MD).
4. Rotate the l L knob (MD) to display “MD lop Read”.
5. “MD @@.@/##.#” is displayed and the recorded contents are displayed.
@@.@ : indicates the Iop value labeled on the pick-up.
##.#
##.#
: indicates the Iop value after adjustment
6. To end, press the MENU/NO button (MD) to display “MD Iop Read”. Then press the ?/1 button (TA).