5-7-4. Auto Check
This test mode performs CREC and CPLAY automatically for
mainly checking the characteristics of the optical pick-up. To
perform this test mode, the laser power must first be checked.
Perform Auto Check after the laser power check and Iop compare.
Procedure:
1. Click the 
[ENTER/YES]
. If “LDPWR                    ” is displayed,
it means that the laser power check has not been performed. In
this case, perform the laser power check and Iop compare, and
then repeat from step 1.
2. If a disc is in the mechanical deck, it will be ejected forcibly.
“DISC IN” will be displayed in this case. Load a test disc (MDW-
74/GA-1) which can be recorded.
3. If a disk is loaded at step 2, the check will start automatically.
4. When  “XX CHECK” is displayed, the item corresponding to
XX will be performed.
When “06 CHECK” completes, the disc loaded at step 2 will be
ejected. “DISC IN” will be displayed. Load the check disc (MD)
TDYS-1.
5. When the disc is loaded, the check will automatically be resumed
from “07 CHECK”.
6. After completing to test item “12 check”, check OK or NG will
be displayed. If all items are OK, “CHECK ALL OK” will be
displayed. If any item is NG, it will be displayed as “NG:xxxx”.
When “CHECK ALL OK” is displayed, it means that the optical
pick-up is normal. Check the operations of the other spindle motor,
sled motor, etc.
When displayed as “NG:xxxx”, it means that the optical pick-up
is faulty. In this case, replace the optical pick-up.
5-7-5. Other Checks
All the following checks are performed by the Auto Check mode.
They therefore need not be performed in normal operation.
5-7-6. Traverse Check
5-7-7. Focus Bias Check
5-7-8. C PLAY Check
5-7-9. Self-Recording/Playback Check
5-7-6. Traverse Check
Connection:
Checking Procedure:
1. Connect an oscilloscope to CN105 pin 4 (TE) and CN105
pin 6 (VC) on the BD (MD) board.
2. Load a disc (any available on the market). (Refer to Note 1)
3. Click the 
[FF]
 to move the optical pick-up outside the pit and
click the 
[STOP]
 to stop.
4. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “EF MO
CHECK”(C14).
5. Click the 
[ENTER/YES]
 to display “EFB = 
 MO-R”.
(Laser power READ power/Focus servo ON/tracking servo
OFF/spindle (S) servo ON)
6. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not click the 
[JOG UP]
    or
[JOG DOWN]
.
(Read power traverse checking)
Traverse Waveform
7. Click the 
[ENTER/YES]
 to display “EFB = 
 MO-W”.
8. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not click the 
[JOG UP]
    or
[JOG DOWN]
.
(Write power traverse checking)
Traverse Waveform
+
oscilloscope
(DC range)
V: 0.1 V/div
H: 10 ms/div
BD board
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
Note 1:
Data will be erased during MO reading if a recorded disc is
used in this adjustment.
Note 2:
If the traverse waveform is not clear, connect the oscilloscope
as shown in the following figure so that it can be seen more
clearly.
+
oscilloscope
(DC range)
10 pF
330 k 
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
BD board
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
A – B 
I
2 (A + B)
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
A – B 
I
2 (A + B)
30
MDS-NT1
9. Click the 
[ENTER/YES]
 to display “EFB = 
 MO-P”.
Then, the optical pick-up moves to the pit area automatically
and servo is imposed.
10. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not click the 
[JOG UP]
    or
[JOG DOWN]
.
Traverse Waveform
11. Click the 
[ENTER/YES]
 to display “EF MO CHECK (C14)”.
The disc stops rotating automatically.
12. Click the 
[EJECT]
 button and take out the disc.
13. Load the check disc (MD) TDYS-1.
14. Click the 
[JOG UP]
  or 
[JOG DOWN]
 and display “EF CD
CHECK” (C15).
15. Click the 
[ENTER/YES]
 to display “EFB = 
 CD”. Servo is
imposed automatically.
16. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not click the 
[JOG UP]
    or
[JOG DOWN]
.
Traverse Waveform
17. Click the 
[ENTER/YES]
 to display “EF CD CHECK” (C15).
18. Click the 
[EJECT]
 and take out the check disc (MD) TDYS-1.
Check Location: BD board (see page 35)
5-7-7. Focus Bias Check
Change the focus bias and check the focus tolerance amount.
Checking Procedure:
1. Load the test disk (MDW-74/GA-1).
2. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “CPLAY2
MODE” (C36).
3. Click the 
[ENTER/YES]
 to display “CPLAY2MID”.
4. Click the 
[MENU/NO]
 when “C = 
 AD = 
” is displayed.
5. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “FBIAS
CHECK” (C16).
6. Click the 
[ENTER/YES]
 to display “
/
 c = 
”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [c =] indicate
the focus bias value.
Check that the C1 error is below 20 and ADER is below 2.
7. Click the 
[ENTER/YES]
 to display “
/
 b = 
”.
Check that the C1 error is about 100 and ADER is below 2.
8. Click the 
[ENTER/YES]
 to display “
/
 a = 
”.
Check that the C1 error is about 100 and ADER is below 2.
9. Click the 
[MENU/NO]
, then click the 
[EJECT]
 and take out the
test disc.
5-7-8. C PLAY Check
MO Error Rate Check
Checking Procedure:
1. Load the test disk (MDW-74/GA-1).
2. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “CPLAY2
MODE” (C36).
3. Click the 
[ENTER/YES]
 to display “CPLAY2MID”.
4. The display changes to “C = 
  AD = 
”.
5. If the C1 error rate is below 20, check that ADER is 00.
6. Click the
[MENU/NO]
 to stop playback, then Click the
[EJECT]
 and take out the test disc.
CD Error Rate Check
Checking Procedure:
1. Load the check disc (MD) TDYS-1.
2. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “CPLAY2
MODE” (C36).
3. Click the 
[ENTER/YES]
 to display “CPLAY2MID”.
4. The display changes to “C = 
 AD = 
”.
5. Check that the C1 error rate is below 20.
6. Click the
[MENU/NO]
 to stop playback, then click the
[EJECT]
 and take out the check disc.
5-7-9. Self-Recording/playback Check
Prepare a continuous recording disc using the unit to be repaired
and check the error rate.
Checking Procedure:
1. Load a recordable disc (blank disc).
2. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display
“CREC 2MODE” (C37).
3. Click the 
[ENTER/YES]
 to display “CREC 2MID”.
4. When recording starts and display “CREC 2 @@@@” (@@@@
is the address).
5. About 1 minute later, click the 
[MENU/NO]
 to stop continu-
ous recording.
6. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “CPLAY2
MODE” (C36).
7. Click the 
[ENTER/YES]
 to display “CPLAY2MID”.
8. “C = 
 AD = 
” will be displayed.
9. Check that the C1 error becomes below 20 and the AD error
below 2.
10. Click the
[MENU/NO]
 to stop playback, then click the
[EJECT]
 and take out the disc.
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
A – B 
I
2 (A + B)
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
A – B 
I
2 (A + B)
31
MDS-NT1
5-8. INITIAL  SETTING  OF  ADJUSTMENT  VALUE
Note:
Mode which sets the adjustment results recorded in the non-volatile
memory to the initial setting value. However the results of the tempera-
ture compensation offset adjustment will not change to the initial setting
value.
If initial setting is performed, perform all adjustments again excluding the
temperature compensation offset adjustment.
For details of the initial setting, refer to “5-5. Precautions for Adjustments”
and execute the initial setting before the adjustment as required.
Setting Procedure:
1. Click the 
[JOG UP]
  or 
[JOG  DOWN]
 to display “ADJ
CLEAR”  (C28).
2. Click the 
[ENTER/YES]
. “Complete!” will be displayed mo-
mentarily and initial setting will be executed, after which “ADJ
CLEAR” (C28) will be displayed.
5-9. RECORDING  AND  DISPLAYING  THE  Iop
INFORMATION
The Iop data can be recorded in the non-volatile memory. The Iop
value on the optical pick-up label and the Iop value after the ad-
justment will be recorded. Recording these data eliminates the need
to read the label on the optical pick-up.
Recording Procedure:
1. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “Iop Write”
(C05), and click the 
[ENTER/YES]
.
2. The display becomes “Ref=@@@.@” (@ is an arbitrary num-
ber) and the numbers which can be changed will blink.
3. Input the Iop value on the optical pick-up label.
To select the number : Click the 
[JOG UP]
  or 
[JOG DOWN]
.
To select the digit : Click the 
[PUSH]
.
4. When the
[ENTER/YES]
 is clicked, the display becomes
“Measu=@@@.@” (@ is an arbitrary number).
5. As the adjustment results are recorded for the 4 value. Leave it
as it is and click the 
[ENTER/YES]
.
6. “Complete!!” will be displayed momentarily. The value will
be recorded in the non-volatile memory and the display will
become “Iop Write” (C05).
Display Procedure:
1. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “Iop Read”
(C26), and click the 
[ENTER/YES]
.
2. “@@.@/##.#” is displayed and the recorded contents are dis-
played.
@@.@ indicates the Iop value on the optical pick-up label.
##.# indicates the Iop value after adjustment
3. To end, click the 
[PUSH]
 or 
[MENU/NO]
 to display “Iop Read”
(C26).
5-10.TEMPERATURE COMPENSATION OFFSET
ADJUSTMENT
Save the temperature data at that time in the non-volatile memory
as 25 ˚C reference data.
Note:
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to 28 ˚C.
Perform it immediately after the power is turned on when the internal
temperature of the unit is the same as the ambient temperature of 22 ˚C
to 28 ˚C.
3. When D101 has been replaced, perform this adjustment after the tem-
perature of this part has become the ambient temperature.
Adjusting Procedure:
1. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “TEMP AD-
JUST” (C03).
2. Click the 
[ENTER/YES]
 to select the “TEMP ADJUST” mode.
3. “TEMP = 
 [OK” and the current temperature data will be
displayed.
4. To save the data, click the 
[ENTER/YES]
.
When not saving the data, click the 
[MENU/NO]
.
5. When the 
[ENTER/YES]
 is clicked, “TEMP = 
 SAVE” will
be displayed and turned back to “TEMP ADJUST” (C03) dis-
play then. When the 
[MENU/NO]
 is clicked, “TEMP ADJUST”
(C03) will be displayed immediately.
Specified Value:
The “TEMP =  
” should be within “E0 - EF”, “F0 - FF”, “00 -
0F”,  “10 - 1F” and “20 - 2F”.
5-11. LASER POWER ADJUSTMENT
Check the Iop value of the optical pick-up before adjustments.
(Refer to 5-9. Recording and Displaying Iop Information)
Connection:
Adjusting Procedure:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, click the 
[FF]
    or
[FR]
 to move the optical pick-up)
Connect the digital voltmeter to CN105 pin 1 (I+3V) and
CN105 pin 2 (Iop) on the BD (MD) board.
2. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “LDPWR
ADJUST” (C04).
(Laser power : For adjustment)
3. Click the 
[ENTER/YES]
 once to display “L 0.90 mW $ 
”.
4. Click the 
[JOG UP]
  or 
[JOG DOWN]
 so that the reading of
the laser power meter becomes specified value. Click the
[ENTER/YES]
 after setting the range knob of the laser power
meter, and save the adjustment results. (“LD SAVE $ 
” will
be displayed for a moment)
Specified Value:
Laser power meter reading: 0.85 to 0.91 mW (KMS-262A)
0.90 to 0.95 mW (KMS-262E)
5. Then “L 8.40 mW $ 
” (KMS-262A) or “L 8.65 mW $ 
(KMS-262E) will be displayed.
Optical pick-up
objective lens
laser
power meter
+
BD board
digital voltmeter
CN105 pin 
1
 (I +3 V)
CN105 pin 
2
 (Iop)
32
MDS-NT1
6. Click the 
[JOG UP]
  or 
[JOG DOWN]
 so that the reading of
the laser power meter becomes specified value, click the
[ENTER/YES]
 to save it.
Specified Value:
Laser power meter reading: 8.2 to 8.6 mW (KMS-262A)
8.5 to 8.8 mW (KMS-262E)
Note:
Do not perform the emission with 8.4 mW more than 15 seconds
continuously.
7. Then, click the 
[JOG  UP]
 or 
[JOG  DOWN]
 to display
“LDPWR CHECK” (C13).
8. Click the 
[ENTER/YES]
 once to display “L 0.90 mW $ 
”.
Check that the reading of the laser power meter become speci-
fied value.
Specified Value:
Laser power meter reading: 0.84 to 0.92 mW (KMS-262A)
0.90 to 0.96 mW (KMS-262E)
9. Click the  
[ENTER/YES]
 button once more to display “L 8.40
mW $ 
” (KMS-262A) or “L 8.65 mW $ 
” (KMS-262E).
Check that the reading the laser power meter and digital volt-
meter satisfy the specified value.
Note down the digital voltmeter reading value.
Specified Value:
Laser power meter reading : 8.4 
±
 0.3 mW (KMS-262A)
8.65 
±
 0.25 mW (KMS-262E)
Digital voltmeter reading : Value on the optical pick-up label
±
10%
(Optical pick-up label)
10. Click the 
[MENU/NO]
 to display “LDPWR CHECK” (C13)
and stop the laser emission.
(The 
[MENU/NO]
 is effective at all times to stop the laser
emission.)
11. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “Iop Write”
(C05).
12. Click the 
[ENTER/YES]
. When the display becomes
Ref=@@@.@ (@ is an arbitrary number), click the 
[ENTER/YES]
to display “Measu=@@@.@” (@ is an arbitrary number).
13. The numbers which can be changed will blink. Input the Iop
value noted down at step 9.
To select the number : Click the 
[JOG UP]
  or 
[JOG DOWN]
.
To select the digit : Click the 
[PUSH]
.
14. When the 
[ENTER/YES]
 is clicked, “Complete!” will be dis-
played momentarily. The value will be recorded in the non-
volatile memory and the display will become “Iop Write”
(C05).
Note:
After step 4, each time the 
[ENTER/YES]
 is clicked, the display
will be switched “L 0.70 mW $ 
” and “LD 7.50 mW $ 
”.
Nothing needs to be performed here.
Adjustment Location: BD board (see page 35)
5-13. TRAVERSE  ADJUSTMENT
Connection:
Adjusting Procedure:
1. Connect an oscilloscope to CN105 pin 4 (TE) and CN105
pin 6 (VC) on the BD board.
2. Load a disc (any available on the market). (Refer to Note 1)
3. Click the 
[STOP]
  after the 
[FF]
 clicked to move the optical
pick-up outside the pit.
4. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “EF MO
ADJUST” (C07).
5. Click the 
[ENTER/YES]
 to display “EFB = 
 MO-R”.
(Laser power READ power/Focus servo ON/tracking servo
OFF/spindle (S) servo ON)
6. Click the 
[JOG UP]
  or 
[JOG DOWN]
 so that the waveform
of the oscilloscope becomes the specified value.
(When the 
[JOG UP]
  or 
[JOG DOWN]
 is clicked, the 
 of
“EFB= 
” changes and the waveform changes.) In this ad-
justment, waveform varies at intervals of approx. 2%. Adjust
the waveform so that the specified value is satisfied as much
as possible.
(Read power traverse adjustment)
Traverse Waveform
Note 1:
Data will be erased during MO reading if a recorded disc is
used in this adjustment.
Note 2:
If the traverse waveform is not clear, connect the oscilloscope
as shown in the following figure so that it can be seen more
clearly.
+
oscilloscope
(DC range)
10 pF
330 k 
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
BD board
+
oscilloscope
(DC range)
V: 0.1 V/div
H: 10 ms/div
BD board
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
A
B
VC
Specification A = B
5-12. Iop NV SAVE
Write the reference values in the nonvolatile memory to perform
“Iop compare”. As this involves rewriting the reference values, do
not perform this procedure except when adjusting the laser power
during replacement of the optical pick-up and when replacing the
IC102. Otherwise the optical pick-up check may deteriorate.
Note:
Perform this function with the optical pick-up set at room tempera-
ture.
Procedure:
1. Click the 
[JOG UP]
  or 
[JOG DOWN]
 to display “Iop NV Save”
(C06).
2. Click the 
[ENTER/YES]
 and display “Iop [stop]”.
3. After the display changes to “Iop =xxsave?”, click the 
[ENTER/YES]
.
4. After “Complete!” is displayed momentarily, the display changes
to “Iop 8.4 mW”.
5. After the display changes to “Iop=yysave?”, click the 
[ENTER/YES]
.
6. When “Complete!” is displayed, it means that Iop NV saving
has been completed.
KMS
262A
20101
B0825
Iop = 82.5 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 (
)
(For details of the method for
checking this value, refer to “8.
Recording and Displaying the Iop
Information”.)