Iop = 57.6 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 (
)
6. Press the   . or  >  button so that the reading of the laser
power meter becomes 6.9 to 7.1 mW, press the   7   button and
save it.
Note : Do not perform the emission with 7.0 mW more than 15
seconds continuously.
7. Then, press the   . or  >  button and display “LDPWR
CHECK” .
8. Press the  7  button once and display “LD 0.9 mW $ 
”.
Check that the reading of the laser power meter become 0.85 to
0.91 mW.
9. Press the  7  button once more and display “LD 7.0 mW $
”. Check that the reading the laser power meter and digital
volt meter satisfy the specified value.
Note down the digital voltmeter reading value.
Specified Value :
Laser power meter reading : 7.0 ± 0.2 mW
Digital voltmeter reading : Optical pick-up displayed value ± 10%
(Optical pick-up label)
10. Press the  x  button and display “LDPWR CHECK”   and stop
the laser emission.
(The  x  button is effective at all times to stop the laser emis-
sion.)
11. Press the   . or  >  button to display “Iop Write” .
12. Press the  7  button. When the display becomes
Ref=@@@.@ (@ is an arbitrary number), press the  7  button
to display “Measu=@@@.@” (@ is an arbitrary number).
13. The numbers which can be changed will blink. Input the Iop
value noted down at step 9.
To select the number : Press the   . or  >  button.
To select the digit : Press the  7  button.
14. When the  7  button is pressed, “Complete!” will be displayed
momentarily. The value will be recorded in the non-volatile
memory and the display will become “Iop Write” .
Note 1: After step 4, each time the  7  button is pressed, the
display will be switched between “LD 0.7 mW $ 
”, “LD
6.2 mW $ 
”, and “LD Wp                   $ 
”. Nothing needs
to be performed here.
(For details of the method for checking
this value, refer to “5-8. Recording and
Displaying the Iop Information”.)
5-12. TRAVERSE  ADJUSTMENT
Connection :
Adjusting Procedure :
1. Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin
6
 (VC) of the BD board.
2. Load a test disc (MDW-74/GA-1). (Refer to Note 1.)
3. Press the  >  button and move the optical pick-up outside the
pit.
4. Press the   . or  >  button and display “EF MO ADJUS” .
5. Press the  7  button and display “EFB = 
 MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Press the   . or  >  button so that the waveform of the
oscilloscope becomes the specified value.
(When the  . or  >  button is pressed, the 
 of “EFB=
” changes and the waveform changes.) In this adjustment,
waveform varies at intervals of approx. 2%. Adjust the wave-
form so that the specified value is satisfied as much as possible.
(Read power traverse adjustment)
(Traverse Waveform)
7. Press the  7  button and save the result of adjustment to the
non-volatile memory (“EFB = 
 SAVE” will be displayed for a
moment. Then “EFB = 
 MO-W” will be displayed).
8. Press the  . or  >  button so that the waveform of the
oscilloscope becomes the specified value.
(When the  . or  >  button is pressed, the 
 of “EFB- 
MO-W” changes and the waveform changes.) In this adjustment,
waveform varies at intervals of approx. 2%. Adjust the wave-
form so that the specified value is satisfied as much as possible.
(Write power traverse adjustment)
(Traverse Waveform)
9. Press the  7  button, and save the adjustment results in the
non-volatile memory. (“EFB = 
 SAVE” will be displayed for
a moment.)
10. “EFB = 
 MO-P”. will be displayed.
The optical pick-up moves to the pit area automatically and servo
is imposed.
V : 0.5 V/div
H : 10 ms/div
Input : DC mode
Oscilloscope
BD board
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
VC
A
B
Specification A = B
VC
A
B
Specification A = B
R
5-11. Iop NV SAVE
Write the reference values in the nonvolatile memory to perform
“Iop compare”. As this involves rewriting the reference values, do
not perform this procedure except when adjusting the laser power
during replacement of the optical pick-up and when replacing the
IC102. Otherwise the optical pick-up check may deteriorate.
Note: Perform this function with the optical pick-up set at room
temperature.
Procedure
1. Press the   . or  >  button to display “Iop NV Save” .
2. Press the  7  button and display “Iop [stop]”.
3. After the display changes to “Iop =xxsave?”, press the  7
button.
4. After “Complete!” is displayed momentarily, the display changes
to “Iop 7.0 mW”.
5. After the display changes to “Iop=yysave?”, press the  7
button.
6. When “Complete!” is displayed, it means that Iop NV saving
has been completed.
38
11. Press the  . or  >  button until the waveform of the oscil-
loscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
12. Press the  7  button, and save the adjustment results in the
non-volatile memory. (“EFB = 
 SAVE” will be displayed for
a moment.)
Next “EF MO ADJUS”  is displayed. The disc stops rotating
automatically.
13. Press the  A  button and remove the disc.
14. Load the check disc (MD) TDYS-1.
15. Press the  . or  >  button and display “EF CD ADJUS” .
16. Press the  7  button and display “EFB = 
 CD”. Servo is
imposed automatically.
17. Press the  . or  >  button so that the waveform of the
oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
18. Press the  7  button, display “EFB = 
 SAVE” for a moment
and save the adjustment results in the non-volatile memory.
Next “EF CD ADJUS” will be displayed.
19. Press the  A  button and remove the check disc (MD) TDYS-1.
Note 1 : MO reading data will be erased during if a recorded disc is
used in this adjustment.
Note 2 : If the traverse waveform is not clear, connect the oscillo-
scope as shown in the following figure so that it can be
seen more clearly.
5-13. FOCUS BIAS ADJUSTMENT
Adjusting Procedure :
1. Load a test disk (MDW-74/GA-1).
2. Press the  . or  >  button and display “CPLAY2MODE”.
3. Press the  7  button and display “CPLAY2MID”.
4. Press the  x  button when “C1 = 
 AD = 
” is displayed.
5. Press the  . or  >  button and display “FBIAS ADJUS” .
6. Press the  7  button and display “ 
/
 a = 
”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [a =] indicate the
focus bias value.
7. Press the  . or  >  button in the clockwise direction and
find the focus bias value at which the C1 error rate becomes 220
(Refer to Note 2).
8. Press the  7  button and display “ 
/
 b = 
”.
9. Press the  . or  >  button in the counterclockwise direc-
tion and find the focus bias value at which the C1 error rate
becomes 220.
10. Press the  7  button and display “ 
/
 c = 
”.
11. Check that the C1 error rate is below 20 and ADER is 00. Then
press the  7  button.
12. If the “(
” in “
 - 
 - 
 (
” is above 20, press the  7
button.
If below 20, press the  x  button and repeat the
adjustment from step 2.
13. Press the  A  button to remove the test disc.
Note 1 : The relation between the C1 error and focus bias is as
shown in the following figure. Find points a and b in the
following figure using the above adjustment. The focal
point position C is automatically calculated from points a
and b.
Note 2 : As the C1 error rate changes, perform the adjustment us-
ing the average vale.
VC
A
B
Specification A = B
VC
A
B
Specification A = B
330 k
Oscilloscope
10pF
BD board
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
C1 error
220
b
c
a
Focus bias value
(F. BIAS)
39
5-14. ERROR RATE CHECK
5-14-1. CD Error Rate Check
Checking Procedure :
1. Load a check disc (MD) TDYS-1.
2. Press the  . or  >  button and display “CPLAY2MODE”.
3. Press the  7  button twice and display “CPLAY2MID”.
4. The display changes to “C1 = 
 AD = 
”.
5. Check that the C1 error rate is below 20.
6. Press the  x  button, stop playback, press the  A  button, and
remove the test disc.
5-14-2. MO Error Rate Check
Checking Procedure :
1. Load a continuously recorded test disc (MDW-74/GA-1).
(Refer to “5-5. Using the Continuously Recorded Disc”.)
2. Press the  . or  >  button and display “CPLAY2MODE”.
3. Press the  7  button and display “CPLAY2MID”.
4. The display changes to “C1 = 
 AD = 
”.
5. If the C1 error rate is below 20, check that ADER is 00.
6. Press the  x  button, stop playback, press the  A  button, and
remove the test disc.
5-15. FOCUS BIAS CHECK
Change the focus bias and check the focus tolerance amount.
Checking Procedure :
1. Load a continuously recorded test disc (MDW-74/GA-1).
(Refer to “5-5. Using the Continuously Recorded Disc”.)
2. Press the  . or  >  button and display “CPLAY2MODE”.
3. Press the  7  button twice and display “CPLAY2MID”.
4. Press the  x  button when “C1 = 
 AD = 
” is displayed.
5. Press the  . or  >  button and display “FBIAS CHECK” .
6. Press the  7  button and display “ 
/
 c = 
”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [c =] indicate the
focus bias value.
Check that the C1 error is below 20 and ADER is below 2.
7. Press the  7  button and display “ 
/
 b = 
”.
Check that the C1 error is below 100 and ADER is below 2.
8. Press the  7  button and display “ 
/
 a = 
”.
Check that the C1 error is below 100 and ADER is below 2
9. Press the  x  button, next press the  A  button, and remove the
continuously recorded disc.
Note 1 : If the C1 error and ADER are above other than the speci-
fied value at points a (step 8. in the above) or b (step 7. in
the above), the focus bias adjustment may not have been
carried out properly. Adjust perform the beginning again.
5-16. AUTO GAIN CONTROL OUTPUT LEVEL
ADJUSTMENT
Be sure to perform this adjustment when the optical pick-up is re-
placed.
If the adjustment results becomes “Adjust NG!”, the optical pick-
up may be faulty or the servo system circuits may be abnormal.
5-16-1. CD Auto Gain Control Output Level Adjustment
Adjusting Procedure :
1. Insert the check disc (MD) TDYS-1.
2. Press the  . or  >  button to display “AG Set (CD)” .
3. When the  7  button is pressed, the adjustment will be
performed automatically.
“Complete!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (CD)” .
4. Press the  A  button to remove the disc.
5-16-2. MO Auto Gain Control Output Level Adjustment
Adjusting Procedure :
1. Insert the reference disc (MDW-74/GA-1) for recording.
2. Press the  . or  >  button to display “AG Set (MO)” .
3. When the  7  button is pressed, the adjustment will be
performed automatically.
“Complete!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (MO)” .
4. Press the  A  button to remove the disc.
40
NOTE:It is useful to use the jig. for checking the waveform. (Refer
to Servicing Note on page 7.)
[BD BOARD] (SIDE B)
D101
IC151
23
1 27
1
1
7
IC101
CN101
CN103
CN102
IC195
IC190
CN105
IC102
*
NOTE
5-17. ADJUSTING POINTS AND CONNECTING POINTS
[BD BOARD] (SIDE A)