DOWNLOAD Sony MDS-J3000 / MDS-J3000ES Service Manual ↓ Size: 5.64 MB | Pages: 66 in PDF or view online for FREE

Model
MDS-J3000 MDS-J3000ES
Pages
66
Size
5.64 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
mds-j3000-mds-j3000es.pdf
Date

Sony MDS-J3000 / MDS-J3000ES Service Manual ▷ View online

— 5 —
RETRY CAUSE DISPLAY MODE
• In this test mode, the causes for retry of the unit during recording can be displayed on the fluorescent display tube.
This is useful for locating the faulty part of the unit.
• The data amount stored in D RAM, number of retries, and retry cause are displayed. Each is displayed in hexadecimal number.
• The display of the D RAM data amount enables data reading, accumulation, ejection, and writing to be performed smoothly. If writing is
not smooth, data may decrease considerably.
Method:
1. Load a recordable disc whose contents can be erased into the unit.
2. Press the EDIT/NO button several times to display “All Erase?” on the fluorescent display tube.
3. Press the YES button.
4. When “All Erase??” is displayed on the fluorescent display tube, the numbers on the music calendar will start blinking.
5. Press the YES button to display “Complete”, and press the 
p button immediately and continue pressing for about 10 seconds.
6. When the “TOC” displayed on the fluorescent display tube goes off, release the 
p button.
7. Press the 
r REC button to start recording.
8. Press the DISPLAY button to display the test mode (Fig. 1), and check the display.
9. The Rt value increases with each retry. If an error occurs after a retry, “Retry Error” will be displayed, and the number of retries counted
will be set back to 0.
10. To exit the test mode, press the POWER button. Turn OFF the power, and after “TOC” disappears, disconnect the power plug from the
outlet.
Fig. 1 Reading the Test Mode Display
SC @@
Rt # #
 
Fluorescent Display Tube Signs
@@ : Displays the DRAM memory amount when at all times.
# #
: Displays the number of retries. When a retry error occurs, the number will be set back to 0.
* *
: Cause of retry
All three displays above are in hexadecimal numbers.
— 6 —
Reading the Retry Cause Display
Hexadecimal
Bit
Binary
Higher Bits
Lower Bits
8
4
2
1
8
4
2
1
b7 b6 b5 b4 b3 b2 b1 b0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
0
When spindle rotation is detected as slow
When more than 3.5 shocks are detected
When ADER was counted more than
five times continuously
When ADIP address is not continuous
(Not used)
When not in focus
When ABCD signal level exceeds the specified range
When CLV is unlocked
When access operation is not performed normally
Hexa-
decimal
Spindle is slow
shock *1
ader5
Discontinuous address
(Not used)
FCS incorrect
IVR rec error
CLV unlock
Access fault
Cause of Retry
Occurring conditions
00
01
02
04
08
10
20
40
80
*1 Some displays are not used depending on the microprocessor version.
Reading the Display:
Convert the hexadecimal display into binary display. If more than two causes, they will be added.
Example
When 42 is displayed:
Higher bit : 4 = 0100 
n b6
Lower bit : 2 = 0010 
n b1
In this case, the retry cause is combined of “CLV unlock” and “ader5”.
When A2 is displayed:
Higher bit : A = 1010 
n b7+b5
Lower bit : 2 = 0010 
n b1
The retry cause in this case is combined of “access fault”, “IVR rec error”, and “ader5”.
Hexadecimal 
n
 Binary Conversion Table
Hexadecimal
Binary
Hexadecimal
Binary
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
— 7 —
SECTION  2
GENERAL
1
2
3
4
5
6
7
8 9
1 POWER switch
2 TIMER switch
3 Disc compartment
4 § button
5 ·P button
6 p button
7 r button
8 EDIT/NO button
9 YES button
!º AMS knob
!¡ INPUT switch
!™ Remote sensor
!£ REC LEVEL knob
!¢ SCROLL/CLOCK SET  button
!∞ DISPLAY/CHAR button
!§ 0/) buttons
!¶ Display window
!• PHONES LEVEL knob
!ª PHONES jack
0
!™
!∞
!•
— 8 —
This section is extracted from
instruction manual.
Page of 66
Display

Click on the first or last page to see other MDS-J3000 / MDS-J3000ES service manuals if exist.