– 9 –
CD SECTION
Note:
Tracking Balance Adjustment and Tracking Gain Adjustment are
done automatically in this set.
TEST MODE
1. Press the CD LID OPEN/CLOSE DET switch (S424) on the
PUSH SWITCH board.
2. Under standby condition (when the clock appears in the dis-
play), short the BP (CD TEST AUTO).
Note:
 If the power is supplied to the microprocessor once, it is backed up
for 3 minutes, therefore the TEST mode will not be activated within
3 minutes even if the power is turned on again. In this case, short
instantaneously the BP (CD TEST MANUAL).
3. Press the  fl key, and the focus search is repeated.
At this time, check that the optical pick-up objective lens moves
smoothly without a sticking or noise.
4. Load the test disc (YEDS-18: Part No. 3-702-101-01), and per-
form automatic adjustment after the focus search succeeded.
5. After automatic adjustment is finished, move the sled motor
to the center. At this time, keep pressing the + and =
keys to confirm that optical pick-up moves smoothly via most
inside track 
 most outside track 
 most inside track with-
out a sticking or noise.
6. Confirm the traverse waveform.
7. Press the [WAKE UP TRACK] key.
8. The tracking servo and the sled servo are turned on, the mute
is cancelled.
9. Playback the 2nd track.
10. Adjust the RF and jitter waveforms.
Connecting points: MAIN Board (See page 12)
Focus Bias Adjustment
This adjustment is to be done when the optical block is replaced.
Connection:
Adjustment Procedure:
1. Connect the oscilloscope to TP504 (VREF) and TP503 (RF)
on the MAIN board.
2. Insert the test disc (YEDS-18: Part No.3-702-101-01) and press
fl key to play.
3. Move the optical pick-up to the music area on the disc to en-
able easy visibility of the eye pattern by + or = key
pressing.
4. Adjust RV501 so that the oscilloscope waveform is as shown
in the figure below (eye pattern).
A good eye pattern means that the diamond shape (≈) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
Adjustment Location: MAIN Board (See page 12)
MAIN board
TP503 (RF)
TP504 (VREF)
+
oscilloscope
(AC range)
VOLT/DIV: 0.2 V
TIME/DIV: 500 ns
1.3 
±
 0.5 Vp-p
When observing the eye pattern, set the oscilloscope 
for AC range and raise vertical sensitivity.
– 10 –
Focus Gain Adjustment
A frequency response analyzer is necessary in order to perform
this adjustment exactly.
However, this gain has a margin, so even if it is slightly off, there
is no problem. Therefore, do not perform this adjustment.
Focus gain determines the optical pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock
when the 2-axis device operate.
However, as these reciprocate, the adjustment is at the point where
both are satisfied.
• When gain is raised, the noise when the 2-axis device operates
increases.
• When gain is lowered, mechanical shock and skipping occurs
more easily.
• When gain adjustment is off, the symptoms below appear.
The following is a simple adjustment method.
– Primary Adjustment –
Note:
Since exact adjustment cannot be performed, remember the posi-
tions of the controls before performing the adjustment. If the posi-
tions after the primary adjustment are only a little different, return
the controls to the original position.
Connection:
• The time until music starts becomes longer for
STOP 
 PLAY or automatic selection.
(=, + buttons pressed)
(Normally takes about 2 seconds)
• Music does not start and disc continues to
rotate for STOP 
 PLAY or automatic
selection.
(=, + buttons pressed)
• Sound is interrupted during PLAY.
Or time counter display stops progressing.
• More noise during 2-axis device operation
Gain
Focus
Symptoms
low
high
Procedure:
1. Keep the set horizontal.
If the set is not horizontal, this adjustment cannot be per-
formed due to the gravity against the 2-axis device
2. Insert the test disc (YEDS-18) and press the fl button.
3. Connect the oscilloscope BT (FEO) and TP504 (VREF) on
the MAIN board.
4. Adjustment RV502 on the MAIN board so that the waveform
is as shown in the figure below.
• Incorrect Examples (DC level changes more than on adjusted
waveform)
)
(
VOLT/DIV: 100 mV
TIME/DIV: 2 mS
100 mV
0 V
VOLT/DIV: 100 mV
TIME/DIV: 2 mS
200 mV
0 V
VOLT/DIV: 100 mV
TIME/DIV: 2 mS
75 mV
0 V
low focus gain
high focus gain
MAIN board
BP (FEO)
TP504 (VREF)
+
oscilloscope
Adjustment Location: MAIN Board (See page 12)
– 11 –
MAIN  CLOCK  SECTION
Main Clock Adjustment
Connection:
Adjustment jig:
Procedure:
1. Connect the frequency counter as the above figures.
2. Adjust CT401 for 4.2495 MHz reading on the frequency
counter.
Specified Value: 4.2490 to 4.2500 MHz
+
adjustment
jig
10 : 1 probe
TP (+5 V)
TP401 (X2)
TP GND (SHIELD) 
+5
IN
GND
frequency counter
MAIN board
OUT
GND
 1 M
 100 k
 100 k
 +5 V
 0.5 pF
 47 uF
 IN
 GND
 1000 pF
 1 M
OUT
GND
INVERTER
(TC7W04F)
+
– 12 –
Adjustment Location and Connecting Points:
T1 AM IF Adjustment
CT401 Main Clock Adjustment
RV501 Focus Bias Adjustment
RV502 Focus Gain Adjustment
RV1 FM VCO Adjustment
L4 MW Frequency Coverage Adjustment
L2 FM Frequency Coverage 
Adjustment
L3-2
CT3
LW Tracking Adjustment
CT1
L1
FM Tracking Adjustment
– MAIN BOARD (Component Side) –
– MAIN BOARD (Conductor Side) –
BP (CD TEST AUTO)
BP (FEO)
BP (CD TEST MANUAL)
TP8
(VCO)
TP7
(+B)
TP12 (FM IN)
TP13 (FM IN GND)
TP50 (VT GND)
TP504 (VREF)
TP53 (VT )
TP503 (RF)
CT4 LW Frequency Coverage Adjustment
CT2
L3-1
MW Tracking Adjustment
TP (+5 V)
C429
TP GND
(SHIELD)
TP401
(X2)
+