– 9 –
AM  IF  ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
AM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
530 kHz
2.8 V
Confirmation
1,710 kHz
9.5V
AM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L3
580 kHz
CT2
1,490 kHz
FM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L2
87.5 MHz
2.1 V
Confirmation
108 MHz
8.5 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
87.5 MHz
CT1
108 MHz
Adjustment Location: MAIN board (See page 11)
FM  VCO Adjustment
Setting:
Procedure:
1. Connect the frequency counter to TP7, 8 as shown the figure
below.
2. Tune the set to 98 MHz.
3. Adjust RV1 for 76 kHz reading on the frequency counter.
Specified Value: 75.95 to 76.05 kHz
Adjustment Location: MAIN board (See page 13)
SECTION  5
ELECTRICAL  ADJUSTMENTS
TUNER  SECTION
0 dB=1 µV
[AM]
Setting:
Function
: RADIO
Band switch : AM
[FM]
Setting:
Function
: RADIO
Band switch : FM
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
• Remove FM antenna in FM adjustments.
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
32 
2
 jack (J301)
FM RF signal
generator
22.5 kHz frequency
deviation by 400 Hz
signal
Output level: as low as possible
+
level meter
2
 jack (J301)
set
32 
0.01 
µ
F
MAIN board
TP12 (FM IN)
digital voltmeter
100 k
MAIN board
TP53 (VT)
FM RF SSG
Carrier frequency: 98 MHz
Modulation: 400 Hz, 30% FM modulation
Output level: 0.1 V (100 dB)
MAIN board
TP12 (FM IN)
0.01 
µ
F
set
µ
F
TP8 (VCO)
+
frequency counter
33 k
TP7 (+B)
+
MAIN board
– 10 –
CD SECTION
Note:
Tracking Balance Adjustment and Tracking Gain Adjustment are
done automatically in this set.
TEST MODE
1. Press the CD LID OPEN/CLOSE DET switch (S424) on the
PUSH SWITCH board.
2. Under standby condition (when the clock appear in the dis-
play), short the BP (CD TEST AUTO).
Note:
 If the power is supplied to the microprocessor once, it is backed up
for 3 minutes, therefore the TEST mode will not be activated within
3 minutes even if the power is turned on again. In this case, short
instantaneously the BP (CD TEST MANUAL).
3. Press the  ^ key, and the focus search is repeated.
At this time, check that the optical pick-up objective lens moves
smoothly without a sticking or noise.
4. Load the test disc (YEDS-18: Part No. 3-702-101-01), and per-
form automatic adjustment after the focus search succeded.
5. After automatic adjustment is finished, move the sled motor
to the center. At this time, keep pressing the + and =
keys to confirm that optical pick-up moves smoothly via most
inside track 
 most outside track 
 most inside track with-
out a sticking or noise.
6. Confirm the traverse waveform.
7. Press the [WAKE UP TRACK] key.
8. The tracking servo and the sled servo are turned on, the mute
is cancelled.
9. Playback the 2nd track.
10. Adjust the RF and jitter waveforms.
Connecting points: MAIN Board (See page 13)
Focus Bias Adjustment
This adjustment is to be done when the optical block is replaced.
Connection:
Adjustment Procedure:
1. Connect the oscilloscope to TP504 (VREF) and TP503 (RF)
on the MAIN board.
2. Insert the test disc (YEDS-18: Part No.3-702-101-01) and press
^ key to play.
3. Move the optical pick-up to the music area on the disc to en-
able easy visibility of the eye pattern by + or = key
pressing.
4. Adjust RV501 so that the oscilloscope waveform is as shown
in the figure below (eye pattern).
A good eye pattern means that the diamond shape (≈) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
Adjustment Location: MAIN Board (See page 13)
MAIN board
TP503 (RF)
TP504 (VREF)
+
oscilloscope
(AC range)
VOLT/DIV: 0.2 V
TIME/DIV: 500 ns
1.3 
±
 0.5 Vp-p
When observing the eye pattern, set the oscilloscope 
for AC range and raise vertical sensitivity.
– 11 –
Focus Gain Adjustment
A frequency response analyzer is necessary in order to perform
this adjustment exactly.
However, this gain has a margin, so even if it is slightly off, there
is no problem. Therefore, do not perform this adjustment.
Focus gain determines the optical pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock
when the 2-axis device operate.
However, as these reciprocate, the adjustment is at the point where
both are satisfied.
• When gain is raised, the noise when the 2-axis device operates
increases.
• When gain is lowered, mechanical shock and skipping occurs
more easily.
• When gain adjustment is off, the symptoms below appear.
The following is a simple adjustment method.
– Primary Adjustment –
Note:
Since exact adjustment cannot be performed, remember the posi-
tions of the controls before performing the adjustment. If the posi-
tions after the primary adjustment are only a little different, return
the controls to the original position.
Connection:
• The time until music starts becomes longer for
STOP 
 PLAY or automatic selection.
(=, + buttons pressed)
(Normally takes about 2 seconds)
• Music does not start and disc continues to
rotate for STOP 
 PLAY or automatic
selection.
(=, + buttons pressed)
• Sound is interrupted during PLAY.
Or time counter display stops progressing.
• More noise during 2-axis device operation
Gain
Focus
Symptoms
low
high
Procedure:
1. Keep the set horizontal.
If the set is not horizontal, this adjustment cannot be per-
formed due to the gravity against the 2-axis device
2. Insert the test disc (YEDS-18) and press the ^ button.
3. Connect the oscilloscope BT (FEO) and TP504 (VREF) on
the MAIN board.
4. Adjustment RV502 on the MAIN board so that the waveform
is as shown in the figure below.
• Incorrect Examples (DC level changes more than on adjusted
waveform)
)
(
VOLT/DIV: 100 mV
TIME/DIV: 2 mS
100 mV
0 V
VOLT/DIV: 100 mV
TIME/DIV: 2 mS
200 mV
0 V
VOLT/DIV: 100 mV
TIME/DIV: 2 mS
75 mV
0 V
low focus gain
high focus gain
MAIN board
BP (FEO)
TP504 (VREF)
+
oscilloscope
Adjustment Location: MAIN Board (See page 13)
– 12 –
MAIN  CLOCK  SECTION
Main Clock Adjustment
Connection:
Adjustment jig:
Procedure:
1. Connect the frequency counter as the above figures.
2. Adjust CT401 for 4.2495 MHz reading on the frequency
counter.
Specified Value: 4.2490 to 4.2500 MHz
+
adjustment
jig
10 : 1 probe
TP (+5 V)
TP401 (4.194 MHz)
TP GND (SHIELD) 
+5
IN
GND
frequency counter
MAIN board
OUT
GND
 1 M
 100 k
 100 k
 +5 V
 0.5 pF
 47 uF
 IN
 GND
 1000 pF
 1 M
OUT
GND
INVERTER
(TC7W04F)
+