DOWNLOAD Sony ICF-CD863 / ICF-CD863L Service Manual ↓ Size: 2.42 MB | Pages: 45 in PDF or view online for FREE

Model
ICF-CD863 ICF-CD863L
Pages
45
Size
2.42 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
icf-cd863-icf-cd863l.pdf
Date

Sony ICF-CD863 / ICF-CD863L Service Manual ▷ View online

ICF-CD863/CD863L
11
3-11. SPEAKER (8.2 cm) (WOOFER) (SP301),  BOX (SP)
4
four screws 
(PTPWH3 
×
 10)
5
speaker (8.2 cm) (woofer)
(SP301)
3
Remove the speaker lead wire
from the groove of the box (SP).
2
Remove the rubber from the
groove of the box (SP).
1
cushion box (SP)
6
box (SP)
12
ICF-CD863/CD863L
MW VCO VOLTAGE ADJUSTMENT (CD863L)
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
531 kHz
2.7 
± 0.05 V
Confirmation
1602 kHz
9.5 
± 1.5 V
LW VCO VOLTAGE ADJUSTMENT (CD863L)
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
CT4
279 kHz
9.0 
± 0.05 V
Confirmation
153 kHz
2.35 
± 0.5 V
MW TRACKING ADJUSTMENT (CD863L)
Adjust for a maximum reading on level meter
L3-1
621 kHz
CT2
1404 kHz
LW TRACKING ADJUSTMENT (CD863L)
Adjust for a maximum reading on level meter
L3-2
162 kHz
CT3
243 kHz
FM VCO VOLTAGE CONFIRMATION
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
Confirmation
87.5 MHz
3.2 
± 0.5 V
Confirmation
108 MHz
10.3 
± 1.5 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
87.5 MHz
CT1
108 MHz
Adjustment Location: MAIN board (See page 13)
TUNER  SECTION
0 dB=1 
µ
V
[AM (MW/LW)]
Setting:
Function : RADIO
RADIO BAND button : AM or MW or LW
[FM]
Setting:
Function : RADIO
RADIO BAND button: FM
• Repeat the procedures in each adjustment several times, and the
tracking adjustments should be finally done by the trimmer ca-
pacitors.
• Remove FM antenna in FM adjustment.
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: 
as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
4.0 
MAIN board
CN303 pin 
3
MAIN board
CN303 pin 
4
FM RF signal
generator
22.5 kHz frequency
deviation by 400 Hz
signal
Output level: 
as low as possible
+
level meter
MAIN board
CN303 pin 
3
MAIN board
CN303 pin 
4
set
4.0 
0.01 
µ
F
MAIN board
TP (GND)
MAIN board
TP (FM IN)
digital voltmeter
TP (VT)
TP (GND)
100 k
MAIN board
SECTION  4
ELECTRICAL  ADJUSTMENTS
FM STEREO ADJUSTMENT
Setting:
Function: RADIO
RADIO BAND button: FM
1. Connect the frequency counter to TP (FMST) and TP (RA-
DIO +B) as shown the figure below.
2. Tune the set to 87.5 MHz (98 MHz).
3. Adjust RV1 for 75.95 to 76.05 kHz reading on the frequency
counter.
Adjustment Location: MAIN board (See page 13)
set
MAIN board
TP (FM IN)
MAIN board
TP (GND)
0.01 
µ
F
Carrier frequency : 87.5 MHz
(98 MHz)
Modulation
: no modulation
Output level
: 0.1 V (100 dB)
FM RF SSG
(   ): Except CD863: Canadian model
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
(
): Italian model
AM VCO VOLTAGE ADJUSTMENT (CD863)
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
530 kHz (531 kHz)
3.0 
± 0.05 V
Confirmation
1,710 kHz
9.7 
± 1.5 V (9.0 ± 1.5 V)
(1602 kHz)
(
): Italian model
AM TRACKING ADJUSTMENT (CD863)
Adjust for a maximum reading on level meter
L3
580 kHz (621 kHz)
CT2
1,490 kHz (1404 kHz)
33 k
+
+
MAIN board
TP (FMST)
TP (RADIO +B)
TP (GND)
frequency counter
µ
F/50 V
ICF-CD863/CD863L
13
13
– MAIN BOARD (Conductor Side) –
TP
(FM IN)
TP (FM ST)
TP
(RADIO B+)
1
4
CN303
TP
(GND)
TP
(VT)
– MAIN BOARD (Component Side) –
CT4 LW VCO Voltage Adjustment (CD863L)
L4 AM (MW) VCO Voltage Adjustment
RV1 FM Stereo Adjustment
T1 AM IF
Adjustment
L1
FM RF
CT2
}
Tracking
Adjustment
L3-2 LW Tracking Adjustment
CT3
}
(CD863L)
L3-1 AM (MW) Tracking
CT2
}
Adjustment
Adjustment Location:
AUTO BRIGHTNESS ADJUSTMENT
Connecting:
1. Set to power off state.
2. Connect a digital voltmeter to TP (DIMMER) and TP (GND)
on the LCD board and confirm that the voltage is 0 V.
3. Turn on the power.
4. Connect the digital voltmeter to TP (DIMMER) and TP (GND)
on the LCD board and adjust RV401 so that the voltage be-
comes 1.5 
± 0.05 V.
5. Turn off the power.
6. Applied sufficient light to IC403 (brightness sensor) on the
DIMMER board and confirm that the voltage is 3.3 
± 0.3 V.
7. Short the BP404.
Adjustment Location:
digital voltmeter
TP (DIMMER)
TP (GND)
100 k
LCD board
+
– LCD BOARD (Component Side) –
RV401 Auto Brightness Adjustment
– LCD BOARD (Conductor Side) –
TP (GND)
TP (DIMMER)
– DIMMER BOARD (Conductor Side) –
IC403
CD SECTION
CD section adjustments are done automatically in this set.
In case of operation check, confirm that focus bias.
FOCUS  BIAS  CHECK
1. Connect the oscilloscope to TP (RF) and TP (GND) on the CD
board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the
u
(CD) button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (
◊) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
VOLT/DIV: 0.2 V (with the 10: 1 probe in use.)
TIME/DIV: 500 ns
0.8 
±
 0.2 Vp-p
When observing the eye pattern, set the oscilloscope 
for AC range and raise vertical sensitivity.
Adjustment Location:
IC701
TP (GND)
TP
(RF)
– CD BOARD (Conductor Side) –
ICF-CD863/CD863L
14
14
A
A
B
B
D
D
F
F
E
E
C
C
I-V AMP
DETECTOR
12
11
17
18
26
SL+
SL–
F–
F–
F+
F+
T+
T+
T–
T–
SPINDLE
MOTOR DRIVE
M701
(SPINDLE)
S701
(LIMIT)
SLED
MOTOR DRIVE
27
M702
(SLED)
FOCUS
COIL DRIVE
TRACKING
COIL DRIVE
SP+
SP–
3
25
9
19
FIN
TIN
SLIN
SPIN
FOCUS/TRACKING COIL DRIVE,
SPINDLE/SLED MOTOR DRIVE
IC702
LD
LD
PD
PD
LASER DIODE
OPTICAL PICK-UP
(KSS-213R)
2-AXIS
DEVICE
(FOCUS)
(TRACKING)
2
1
1
M
M
7
MUTE
AUTOMATIC
POWER
CONTROL
Q701
8
FIN2
7
FIN1
+
MIX
4
RF
LPF
EQ
PH
BH
10
TIN2
9
TIN1
A/D
SW
LPF
TRACK
JUMP
TBAL
80
LDD
APC
AUDIO
ADJUST
SERVO
PROCESSOR
RUPTURE
DETECT
79
LDS
SW
AGC
D/A
13
FE
15
TE
20
TDO
21
FDO
23
SLDO
22
SPDO
S/H
3
EFM
IN
SLISE LEVEL
CONTROL
ERROR
CORRECTION
AUDIO CD
C1 – 2, C2 – 2
RAM
8FS
DIGITAL
FILTER
INTERPOLATION
MUTE
ATTENUATION
DEEMPHASIS
1 BIT
DAC
42
LCHO
45
RCHO
LPF
39
DOUT
AUDIO
OUT
FSEQ
PLL
VCEC
CLV, CAV
CONTROL
FRAME SYNC
DETECT,
PROTECT INSERT,
EFM DECODE
31
RAM
DRF
67
25
CONT4
72
CONT1
66
RES
61
CE
62
CL
63
DI
64
DO
65
WRQ
RF AMP, FOCUS/TRACKING SERVO,
DIGITAL SIGNAL PROCESSOR,
CLV SERVO, D/A CONVERTER
IC701
50 WRQ
56 DATA-IN CD
54 DATA CD/RADIO
55 CLK CD/RADIO
53 CE CD/RADIO
58 XRST
57 DRF
41 FSEQ
CD-L
39
CD OPEN
D304
D305
D306
(Page 16)
A
SYSTEM
CONTROLLER
IC401 (1/2)
R-CH
: CD PLAY
• R-ch is omitted due to same as L-ch.
• SIGNAL PATH
DI, CLK, CE
(Page 15)
B
GENERAL-PURPOSE
PORTS
COMMAND
INTERFACE
DRF
XOUT
XIN
49
48
X701
33.8688MHz
DI
CLK
CE
D52
D53
D54
S301
CD LID OPEN/CLOSE
DETECT
SECTION  5
DIAGRAMS
5-1.
BLOCK  DIAGRAM  – CD Section –
Page of 45
Display