Sony ICF-CD825RM Service Manual ▷ View online
– 32 –
IC501
CXA1782BQ
– 33 –
IC502
CXD2508AQ
– 34 –
5-7.
IC PIN FUNCTION DESCRIPTION
•
MAIN BOARD IC401
µ
PD75304BGF-054-3B9 (SYSTEM CONTROLLER/LCD DRIVER)
Pin No.
Pin Name
I/O
Function
1 to 3
S12 to S14
O
Segment drive signal output to the liquid crystal display (LCD901)
4 to 6
SEG17 to SEG15
O
Segment drive signal output to the liquid crystal display (LCD901)
7 to 20
SEG14 to SEG1
O
Segment drive signal output terminal Not used (open)
21, 22
COM0, COM1
O
Common drive signal output to the liquid crystal display (LCD901)
23, 24
COM2, COM3
O
Common drive signal output terminal Not used (open)
25
BIAS
O
Liquid crystal display drive bias control output terminal
26 to 28
VLC0 to VLC2
—
Terminal for doubler circuit capacitor connection to develop liquid crystal display drive voltage
29
POWER ON
I/O
30
CD ON
I/O
31
12H/24H
I
Setting terminal for the time display (12/24-hour system) “L”: 12H, “H”: 24H
(fixed at “L” in this set)
(fixed at “L” in this set)
32
TRACKING
I
Setting terminal for the auto tracking adjustment function “L”: auto tracking (fixed at “L”)
33
VSS
—
Ground terminal
34
ALRAM
—
Not used (open)
35
BAL B
O
Tracking balance adjustment control signal output to the CXA1782BQ (IC501)
36
CLOCK
O
Serial data transfer clock signal output to the CXD2508AQ (IC502)
37
XLAT
O
Serial data latch pulse signal output to the CXD2508AQ (IC502)
38
AC IN
I
AC IN detection signal input terminal (for AC IN check) “H”: AC IN OK
39
SQCK
O
Clock signal output for subcode Q data reading to the CXD2508AQ (IC502)
40
P02
O
Not used (open)
41
SQSI
I
Subcode Q data input from the CXD2508AQ (IC502)
42
SENS
I
Internal status detection signal input from the CXD2508AQ (IC502)
43
C IN
I
Track jump count signal input from the CXD2508AQ (IC502)
44
SCOR
I
Subcode sync (S0+S1) detection signal input from the CXD2508AQ (IC502)
45
DOOR
I
CD lid open/close detect switch (S420) input terminal “L”: open, “H”: close
46
DATA
O
Serial data output to the CXD2508AQ (IC502)
47
XRESET
O
Reset signal output to the CXA1782BQ (IC501) and CXD2508AQ (IC502) “L”: reset
48
AU MUT
O
Audio line muting on/off control signal output terminal “L”: muting on
49
BUZZER
O
Beep sound output terminal
50
RADIO ON
O
Radio system power on/off control signal output terminal “L”: radio on
51
KEY IN1
I
Key input terminal WAKE UP TRACK key input (S401)
52
KEY IN2
I
Key input terminal ALARM MODE key input (S402)
53
KEY IN3
I
Key input terminal ALARM B key input (S403)
54
VDD
—
Power supply terminal (+5V)
55
XT1
I
Sub system clock input terminal (32 kHz)
56
XT2
O
Sub system clock output terminal (32 kHz)
57
NC
—
Connected to power supply (+5V)
58
X1
I
Main system clock input terminal (4.19 MHz)
59
X2
O
Main system clock output terminal (4.19 MHz)
60
KEY IN4
I
Key input terminal RADIO SLEEP key input (S404; main unit, S702; remote control unit (RM-
RW1))
RW1))
61
KEY IN5
I
Key input terminal TIME SET/TRACK +
+ key input (S405)
Power on/off control signal output and CD test mode 1 setting terminal
At initial mode: valid/invalid selection of the CD test mode 1 (CD test mode 1 when “L” input)
At normal mode: main power on/off control signal output (power on when “L” output)
At initial mode: valid/invalid selection of the CD test mode 1 (CD test mode 1 when “L” input)
At normal mode: main power on/off control signal output (power on when “L” output)
Power on/off control signal output and CD test mode 2 setting terminal
At initial mode: valid/invalid selection of the CD test mode 2 (CD test mode 2 when “L” input)
At normal mode: CD power on/off control signal output (power on when “L” output)
At initial mode: valid/invalid selection of the CD test mode 2 (CD test mode 2 when “L” input)
At normal mode: CD power on/off control signal output (power on when “L” output)
– 35 –
Pin No.
Pin Name
I/O
Function
62
KEY IN6
I
Key input terminal ALARM A key input (S406)
63
KEY IN7
I
Key input terminal CD
( P key input (S407; main unit, S701; remote control unit (RM-
RW1))
64
KEY IN8
I
Key input terminal TIME SET/TRACK –
= key input (S408)
65
KEY IN9
I
Key input terminal TRACK/CLOCK key input (S409)
66
KEY IN10
I
Key input terminal OFF ALARM RESET key input (S410; main unit, S703; remote control
unit (RM-RW1))
unit (RM-RW1))
67
KEY IN11
I
Key input terminal SNOOZE/SLEEP OFF key input (S411; main unit, S704; remote control
unit (RM-RW1))
unit (RM-RW1))
68
RESET
I
System reset signal input from the reset signal generator (IC402) “L”: reset
“L” is input for several 100 msec after power on, then it changes to “H”
“L” is input for several 100 msec after power on, then it changes to “H”
69
S0
O
Segment drive signal output terminal Not used (open)
70 to 80
S1 to S11
O
Segment drive signal output to the liquid crystal display (LCD901)
Click on the first or last page to see other ICF-CD825RM service manuals if exist.