DOWNLOAD Sony ICF-CD825RM Service Manual ↓ Size: 870.09 KB | Pages: 39 in PDF or view online for FREE

Model
ICF-CD825RM
Pages
39
Size
870.09 KB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
icf-cd825rm.pdf
Date

Sony ICF-CD825RM Service Manual ▷ View online

– 32 –
IC501
CXA1782BQ
– 33 –
IC502
CXD2508AQ
– 34 –
5-7.
IC  PIN  FUNCTION  DESCRIPTION
 MAIN BOARD  IC401  
µ
PD75304BGF-054-3B9 (SYSTEM CONTROLLER/LCD DRIVER)
Pin No.
Pin Name
I/O
Function
1 to 3
S12 to S14
O
Segment drive signal output to the liquid crystal display (LCD901)
4 to 6
SEG17 to SEG15
O
Segment drive signal output to the liquid crystal display (LCD901)
7 to 20
SEG14 to SEG1
O
Segment drive signal output terminal    Not used (open)
21, 22
COM0, COM1
O
Common drive signal output to the liquid crystal display (LCD901)
23, 24
COM2, COM3
O
Common drive signal output terminal    Not used (open)
25
BIAS
O
Liquid crystal display drive bias control output terminal
26 to 28
VLC0 to VLC2
Terminal for doubler circuit capacitor connection to develop liquid crystal display drive voltage
29
POWER ON
I/O
30
CD ON
I/O
31
12H/24H
I
Setting terminal for the time display (12/24-hour system)    “L”: 12H, “H”: 24H                              
(fixed at “L” in this set)
32
TRACKING
I
Setting terminal for the auto tracking adjustment function    “L”: auto tracking (fixed at “L”)
33
VSS
Ground terminal
34
ALRAM
Not used (open)
35
BAL B
O
Tracking balance adjustment control signal output to the CXA1782BQ (IC501)
36
CLOCK
O
Serial data transfer clock signal output to the CXD2508AQ (IC502)
37
XLAT
O
Serial data latch pulse signal output to the CXD2508AQ (IC502)
38
AC IN
I
AC IN detection signal input terminal (for AC IN check)    “H”: AC IN OK
39
SQCK
O
Clock signal output for subcode Q data reading to the CXD2508AQ (IC502)
40
P02
O
Not used (open)
41
SQSI
I
Subcode Q data input from the CXD2508AQ (IC502)
42
SENS
I
Internal status detection signal input from the CXD2508AQ (IC502)
43
C IN
I
Track jump count signal input from the CXD2508AQ (IC502)
44
SCOR
I
Subcode sync (S0+S1) detection signal input from the CXD2508AQ (IC502)
45
DOOR
I
CD lid open/close detect switch (S420) input terminal    “L”: open, “H”: close
46
DATA
O
Serial data output to the CXD2508AQ (IC502)
47
XRESET
O
Reset signal output to the CXA1782BQ (IC501) and CXD2508AQ (IC502)    “L”: reset
48
AU MUT
O
Audio line muting on/off control signal output terminal    “L”: muting on
49
BUZZER
O
Beep sound output terminal
50
RADIO ON
O
Radio system power on/off control signal output terminal    “L”: radio on
51
KEY IN1
I
Key input terminal    WAKE UP  TRACK key input (S401)
52
KEY IN2
I
Key input terminal    ALARM MODE key input (S402)
53
KEY IN3
I
Key input terminal    ALARM  B key input (S403)
54
VDD
Power supply terminal (+5V)
55
XT1
I
Sub system clock input terminal (32 kHz)
56
XT2
O
Sub system clock output terminal (32 kHz)
57
NC
Connected to power supply (+5V)
58
X1
I
Main system clock input terminal (4.19 MHz)
59
X2
O
Main system clock output terminal (4.19 MHz)
60
KEY IN4
I
Key input terminal    RADIO  SLEEP key input (S404; main unit, S702; remote control unit (RM-
RW1))
61
KEY IN5
I
Key input terminal    TIME SET/TRACK +  
+ key input (S405)
Power on/off control signal output and CD test mode 1 setting terminal
At initial mode: valid/invalid selection of the CD test mode 1 (CD test mode 1 when “L” input)
At normal mode: main power on/off control signal output (power on when “L” output)
Power on/off control signal output and CD test mode 2 setting terminal
At initial mode: valid/invalid selection of the CD test mode 2 (CD test mode 2 when “L” input)
At normal mode: CD power on/off control signal output (power on when “L” output)
– 35 –
Pin No.
Pin Name
I/O
Function
62
KEY IN6
I
Key input terminal    ALARM  A key input (S406)
63
KEY IN7
I
Key input terminal    CD 
( P key input (S407; main unit, S701; remote control unit (RM-
RW1))
64
KEY IN8
I
Key input terminal    TIME SET/TRACK –  
= key input (S408)
65
KEY IN9
I
Key input terminal    TRACK/CLOCK key input (S409)
66
KEY IN10
I
Key input terminal    OFF  ALARM RESET key input (S410; main unit, S703; remote control 
unit (RM-RW1))
67
KEY IN11
I
Key input terminal    SNOOZE/SLEEP OFF key input (S411; main unit, S704; remote control 
unit (RM-RW1))
68
RESET
I
System reset signal input from the reset signal generator (IC402)    “L”: reset                                   
“L” is input for several 100 msec after power on, then it changes to “H”
69
S0
O
Segment drive signal output terminal    Not used (open)
70 to 80
S1 to S11
O
Segment drive signal output to the liquid crystal display (LCD901)