DOWNLOAD Sony ICD-TX50 Service Manual ↓ Size: 1008.54 KB | Pages: 20 in PDF or view online for FREE

Model
ICD-TX50
Pages
20
Size
1008.54 KB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
icd-tx50.pdf
Date

Sony ICD-TX50 Service Manual ▷ View online

ICD-TX50
13
4-4. SIN
Sine wave can be outputted.
Procedure:
1.  Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “SIN”, and press 
the [
N
/ENT] key.
3.  Sine wave is outputted.
LCD Display
Displayed characters/values are example.
<SIN>
sin  1KHz
Vol:25
 
Initial value:
 
Play back volume  : 25 (stereo)
 fs 
44.1kHz
 
Frequency 
: sin 50Hz
  
 
sin 
100Hz
  
 
sin 
200Hz
 
 
  sin 1KHz (default)
  
 
sin 
8.5KHz
  
 
sin 
10KHz
  
 
sin 
19KHz
  
 
Infi nity zero
 
 
  sin L 1KHz
 
 
  sin R 1KHz
 
 
  SWEEP (100 Hz to 3 kHz: 10 seconds)
 
Sound is outputted from the D-AMP built-in CPU at the time 
of headphone wearing.
 
Key input settings under this mode of operation:
 
[VOL +]  : Volume up
 
[VOL –]  : Volume down
 
[
>
: Frequency up
 
[
.
: Frequency down
Operation of others by the plug/unplug signal (headphone jack) are 
based on operation of this unit.
Releasing method:
Press the [
x
STOP] key, return to test mode menu.
4-5. BEEP
Beep sound (1.3 kHz) can be outputted.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
>
] or [
.
] keys to select the “BEEP”, and press 
the [
N
/ENT] key.
3.  Beep sound (1.3 kHz) is outputted.
LCD Display
Displayed characters/values are example.
<BEEP>
1.3KHz  ON
Vol:25
 
Key input settings under this mode of operation:
 
[VOL +]  : Volume up
 
[VOL –]  : Volume down
Releasing method:
Press the [
x
STOP] key, return to test mode menu.
4-6.  LCD  CONT
Not used for the servicing.
4-7.  LCD  LOW  CONT
Not used for the servicing.
4-8.  LCD  PATTERN
The check of LCD dead pixel is made.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
>
] or [
.
] keys to select the “LCD PATTERN”, 
and press the [
N
/ENT] key.
3.  LCD display pattern is displayed as shown in the following 
fi gure.
LCD Display Pattern
All segments on,
and red LED lights up.
All segments off,
and green LED lights up.
Partial segments on,
and orange LED lights up.
 
Key input settings under this mode of operation:
 
[
>
] or [
.
] : Display pattern change
Releasing method:
Press the [
x
STOP] key, return to test mode menu.
4-9. RTC TEST
The self-test of RTC module can be done.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “RTC TEST”, and 
press the [
N
/ENT] key.
3.  The self-test of RTC module is executed, and result is dis-
played.
0
LCD Display
Displayed characters/values are example.
<RTC  TEST>
OK
RTC self-test result
Releasing method:
Press the [
x
STOP] key, return to test mode menu.
ICD-TX50
14
4-10. BATT 
 
A/D
A/D value (voltage value and temperature value) acquisition can 
be performed.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “BATT A/D”, and 
press the [
N
/ENT] key.
3.  A/D value (voltage value and temperature value) are acquired, 
and they are displayed.
 
(8 bit (The bit shift after LSB side 2 bit omission))
 
Displayed values are always updated.
LCD Display
Displayed characters/values are example.
<BATT  A/D>
BAT:ACTMP:71
XST:A3
Releasing method:
Press the [
x
STOP] key, return to test mode menu.
4-11.  LOW  DET
LOWBATT_XDET (Battery voltage decrease detection signal) 
can be checked.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “LOW DET”, and 
press the [
N
/ENT] key.
3.  The state of LOW DET is displayed.
LCD Display
Displayed characters/values are example.
<LOW  DET>
LOW  DET  :  OFF
 
OFF : LOWBATT_XDET=1 (H)
 
ON  : LOWBATT_XDET=0 (L)
Releasing method:
Press the [
x
STOP] key, return to test mode menu.
4-12. VBUS
VBUS detection signal can be checked.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “VBUS”, and press 
the [
N
/ENT] key.
3.  The state of VBUS_XDET is displayed.
LCD Display
Displayed characters/values are example.
<VBUS>
OFF
 OFF 
VBUS_DET=0 
(L)
 ON 
VBUS_DET=1 
(H)
Releasing method:
Press the [
x
STOP] key, return to test mode menu.
4-13.  KEY  COUNT
The count value of the keys and switches operation can be dis-
played. Distinction of the keys and switches which operated is not 
performed.
Note: It cannot move to other modes from this mode.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “KEY COUNT”, 
and press the [
N
/ENT] key.
3.  The count value of the keys and switches operation is dis-
played.
LCD Display
Displayed characters/values are example.
<KEY  COUNT>
00000
 
Count value increase conditions:
 
One of buttons is pushed.
 
One of switches is slid.
 
micro SD card is inserted.
 
Headphone is inserted.
Releasing method:
Press the [RESET] key on rear side of main unit, reboot this unit.
4-14. SLEEP
It can change into the sleep state for standby current value mea-
surement.
Note: It cannot move to other modes from this mode.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “SLEEP”, and press 
the [
N
/ENT] key.
3.  The sleep state selection screen is displayed.
LCD Display
Displayed characters/values are example.
<SLEEP>
SLEEP:NORMAL
Please  Enter
 
Key input settings under this mode of operation:
 
[
>
] or [
.
] : Sleep mode change (NORMAL 
DEEP)
4.  This unit shifts to the sleep state by pressing the [
N
/ENT] key 
again.
LCD Display
Releasing method:
Press the [RESET] key on the rear side of main unit to turn off the 
power.
ICD-TX50
15
4-15.  BATT  LIFE
The result measured with the battery life measurement fi rmware 
can be displayed.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “BATT LIFE”, and 
press the [
N
/ENT] key.
3.  The result measured with the battery life measurement fi rm-
ware is displayed.
LCD Display
Displayed characters/values are example.
<BATT  LIFE>
----  -  REC  0  Lv1
00/00/00  00:00:00
Recoding mode/
Recodig and playback type/
Battery level
Year/months/days/
Hours/minutes/seconds
 
Recording mode:
 
Recording mode of the fi le recorded or played back at the time 
of measurement is displayed.
 (192/128/M48/LPCM 
(fi le format), H/M/L (microphone sensi-
tivity) etc.)
 
Recording and play back type:
 
The state at the time of measurement is displayed.
 
0: Internal memory
 
1: External memory
 
Battery level:
 
The battery life value is displayed. Value is changed by press-
ing the [
>
] or [
.
] keys.
 Battery 
lebel: 
LV1= 100%
  
LV2= 50%
  
LV3= 25%
  
LV4= >25%
  
LV5= 0%
Releasing method:
Press the [
x
STOP] key, return to test mode menu.
4-16.  WRITER  VER
Not used for the servicing.
4-17.  CHG  LOG
The charge log saved at SRAM can be copied to eMMC.
Procedure:
1.  Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “CHG LOG”, and 
press the [
N
/ENT] key.
3.  The charge log saved at SRAM is copied to eMMC.
LCD Display
Displayed characters/values are example.
<CHG  LOG>
Success
Releasing method:
Press the [
x
STOP] key, return to test mode menu.
4-18.  LREC  LOG
Not used for the servicing.
4-19.  LREC  LOG  Clear
Not used for the servicing.
4-20.  MENU  INIT
This unit can return to the factory shipment settings.
Note: Unique ID and LCD contrast value are not initialized.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “MENU INIT”, and 
press the [
N
/ENT] key.
3.  Initialization is performed.
 
“Success” is displayed, and this unit reboots.
16
ICD-TX50
SECTION  4
EXPLODED  VIEWS
  1 
9-885-167-29  SV PANEL (REAR) ASSY (US, CND, LA)
  1 
9-885-167-30  SV PANEL (REAR) ASSY (AEP)
  1 
9-885-167-31  SV PANEL (REAR) ASSY (E)
  1 
9-885-167-32  SV PANEL (REAR) ASSY (KR)
  1 
9-885-167-33  SV PANEL (REAR) ASSY (CH)
 2 
3-225-873-29 SCREW 
(M1.4)
  3 
9-885-167-34  SV ORNAMENT MIC ASSY
 4 
4-299-924-01 SLEEVE
 5 
4-299-925-01 SPRING 
(CLIP)
 6 
4-299-931-01 ORNAMENT 
(CLIP)
 7 
4-299-930-01 SHAFT 
(CLIP)
 8 
4-299-928-01 CLIP
 9 
4-299-921-01 BASE 
(CLIP)
 10 
3-225-873-27 SCREW 
(M1.4)
 11 
4-424-594-01 BRACE 
(REAR)
  Ref. No. 
Part No. 
Description 
Remark
  Ref. No. 
Part No. 
Description 
Remark
Note:
•  -XX and -X mean standardized parts, so 
they may have some difference from the 
original one.
•  Items marked “*” are not stocked since 
they are seldom required for routine ser-
vice. Some delay should be anticipated 
when ordering these items.
•  The mechanical parts with no reference 
number in the exploded views are not sup-
plied.
•  Color Indication of Appearance Parts Ex-
ample:
  KNOB, BALANCE (WHITE) . . . (RED)
   
 
 
   
 
Parts Color  Cabinet’s Color
4-1.  PANEL (REAR)  SECTION
case (front) section
1
2
6
2
2
3
4
9
10
10
11
5
6
7
8
7
• Abbreviation
  CH 
: Chinese model
  CND  : Canadian model
  KR 
: Korean model
  LA 
: Latin American model
Page of 20