Sony ICD-SX712 / ICD-SX713 / ICD-SX813 Service Manual ▷ View online
SERVICE MANUAL
SUPPLEMENT-1
Ver. 1.2 2012.04
9-889-982-81
Subject: ABOUT THE FIRMWARE WRITING WHEN
REPLACING THE SYSTEM BOARD
File this supplement with the service manual.
ICD-SX712/SX712D/
SX713/SX813
US Model
Canadian Model
AEP Model
ICD-SX712/SX712D
E Model
ICD-SX713/SX813
Chinese Model
ICD-SX712/SX713/SX813
Latin American Model
ICD-SX712
ICD-SX712/SX712D/SX713/SX813
2
ABOUT THE FIRMWARE WRITING WHEN REPLAC-
ING THE SYSTEM BOARD
When the SYSTEM board is replaced, perform processing accord-
ing to the following procedure.
ING THE SYSTEM BOARD
When the SYSTEM board is replaced, perform processing accord-
ing to the following procedure.
Precaution
The contents which are not opened to customers are included
in the following procedure. After you are cautious of handling of
information, execute work under the suffi cient administration.
The contents which are not opened to customers are included
in the following procedure. After you are cautious of handling of
information, execute work under the suffi cient administration.
1. About the preparing of tools
Download the tools used by this work from the homepage of TISS.
When the tools cannot be confi rmed by TISS, confi rm to the ser-
vice headquarters.
Download the tools used by this work from the homepage of TISS.
When the tools cannot be confi rmed by TISS, confi rm to the ser-
vice headquarters.
2. Setting method
Note 1: This work is impossible when battery voltage is not enough.
Do work using the battery with suffi cient battery level.
Procedure:
1. Equip IC recorder with battery.
2. Connect PC and IC recorder with the USB cable.
1. Equip IC recorder with battery.
2. Connect PC and IC recorder with the USB cable.
IC recorder
USB connecting cable
To (USB)
connector
connector
PC
3. Unzip the all fi rmware writing tools on PC.
4. Choose the folder corresponding to the repaired IC recorder
4. Choose the folder corresponding to the repaired IC recorder
from the unzipped folders on PC. (Refer to following table)
Model
name
Destina-
tion
Folder name
SX712
US model
ICD-SXx1x_V1_00_05_U_CA_LA
Canadian
model
model
ICD-SXx1x_V1_00_05_U_CA_LA
AEP model
ICD-SXx1x_V1_00_05_CE7
Latin Ameri-
can model
can model
ICD-SXx1x_V1_00_05_U_CA_LA
Chinese
model
model
ICD-SXx1x_V1_00_05_CN
SX712D
US model
ICD-SXx1x_V1_00_05_U_CA_LA
Canadian
model
model
ICD-SXx1x_V1_00_05_U_CA_LA
AEP model
ICD-SXx1x_V1_00_05_CE7
SX713
E model
ICD-SXx1x_V1_00_05_E
Korean
model
model
ICD-SXx1x_V1_00_05_KR3
Chinese
model
model
ICD-SXx1x_V1_00_05_CN
SX813
E model
ICD-SXx1xNC_V1_00_05_E
Korean
model
model
ICD-SXx1xNC_V1_00_05_KR3
Chinese
model
model
ICD-SXx1xNC_V1_00_05_CN
5. Open the “fwup” folder in selected folder at step 4 on PC, and
execute “SXnewRegionChg.js”.
6. Confi rm that “Browse For Folder” is displayed on PC, and se-
lect the root folder of IC recorder connected by USB.
(In
following
fi gure, IC recorder is recognized as “IC RE-
CORDER (F:)”)
7. Click “OK” button on PC.
8. Confi rm that the screen of IC recorder disappears for a moment
and IC recorder reboots.
Note
2: IC recorder is not turned off by any means until IC recorder
reboots.
9. Confi rm that “Region write fi nished!” is displayed on PC, and
click “OK” button.
10. Open the “fwup” folder in selected folder at step 4 on PC, and
execute “SXnew_Updater.js”.
ICD-SX712/SX712D/SX713/SX813
3
11. Confi rm that “Browse For Folder” is displayed on PC, and se-
lect the root folder of IC recorder connected by USB.
(In
following
fi gure, IC recorder is recognized as “IC RE-
CORDER (F:)”)
12. Click “OK” button on PC.
13. Confi rm that the screen of IC recorder disappears for a moment
and IC recorder reboots.
Note
3: The operation indicator of IC recorder blinks in red color dur-
ing writing.
IC recorder
(Front side)
(Front side)
operation
indicator
indicator
Note
4: IC recorder is not turned off by any means until IC recorder
reboots.
14. Confi rm that “FW update fi nished!” is displayed on PC, and
click “OK” button.
15. Disconnect the USB cable from PC and IC recorder.
16. Remove battery from IC recorder, and fi rmware writing is
16. Remove battery from IC recorder, and fi rmware writing is
completed.
3. Confi rmation method
Procedure:
1. Equip IC recorder with battery, and the power supply of IC
Procedure:
1. Equip IC recorder with battery, and the power supply of IC
recorder is automatically turned on.
2. Press the [
x
/STOP] button, and IC recorder will be in halt con-
dition.
3. While pressing the [T-MARK] and [VOL –] buttons, slide the
[NOISE CUT] switch three times.
Note: The direction (ON or OFF) to slide is not related.
IC recorder
(Rear side)
(Rear side)
IC recorder
(Front side)
(Front side)
[VOL –] button
[T-MARK] button
4. Confi rm that the test mode menu is displayed, and release the
[T-MARK] and [VOL –] buttons.
5. Select “Version” by pressing the [
v
] or [
V
] button, and press
the [
N
/ENT] button.
6. Confi rm that the fi rmware versin and destination setting has
been changed.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
ICD-SX712 E
ARM 1.00.05
DSP 1.00.00
Boot 04
Mar 29 21:18:11
ARM 1.00.05
DSP 1.00.00
Boot 04
Mar 29 21:18:11
Screen display
Destination setting
Firmware version for CPU (ARM section)
Firmware version for CPU (DSP section)
Firmware version for boot loader
Firmware version for CPU (ARM section)
Firmware version for CPU (DSP section)
Firmware version for boot loader
7. Press the [
x
/STOP] button, and return to the test mode menu.
8. Select “FactoryShip” by pressing the [
v
] or [
V
] button, and
press the [
N
/ENT] button.
9. Confi rm that the following screen is displayed, and press the
[
N
/ENT] button.
<Factory ship>
[PLAY]:ENTER
[MENU]:RET
[MENU]:RET
Screen display
10. IC recorder reboots automatically.
11. Remove battery from IC recorder, and confi rmation is com-
11. Remove battery from IC recorder, and confi rmation is com-
pleted.
ICD-SX712/SX712D/SX713/SX813
REVISION HISTORY
Checking the version allows you to jump to the revised page.
Also, clicking the version at the top of the revised page allows you to jump to the next revised page.
Also, clicking the version at the top of the revised page allows you to jump to the next revised page.
Ver.
Date
Description of Revision
1.0
2010.10
New
1.1
2011.02
Addition of US, Canadian, AEP, Latin American models of ICD-SX712.
Addition of ICD-SX712D (US, Canadian, AEP models).
1.2
2012.04
Addition of “ABOUT THE FIRMWARE WRITING WHEN REPLACING THE SYSTEM BOARD”
(SUPPLEMENT-1)
(SMR-12001)