HMZ-T3/T3W
5-1. Processor Unit (HMZ-T3-P/T3W-P)
5-1
SECTION 5
TROUBLESHOOTING
PU Power ON
NG
Checking the AC adapter
Check the connection of the SW FL-2005
OK
Checking the image a wired 
connection by connecting to the 
non-defective PBU / HMU
NG
Confirmation of pass-through work when 
connected to the TV
NG
Confirmation of input HDMI 
connector
Check IC1001 (SU board failure)
OK
OK
Confirmation of IC1007 and CN1004 connector
(SU board failure)
Check the wireless connection 
mode
NG
Operation verification directly connected 
to the source device PBU side
NG
To the analysis of flow PBU / HMU 
side
OK
OK
Failure of the wireless module of PU side
(Exchange and pairing of wireless TX)
Confirmation of sound in PU HP
NG
Confirmation of the waveform and 
soldering of J4001
OK
PU OK
HMZ-T3/T3W
5-2. Head Mounted Unit (HMZ-T3-H/T3W-H)
5-2
Turning ON the power after the AC adapter 
connected to the PBU, confirmation of the green 
LED
NG
Checking the AC adapter
Check the CN300 (USB connector) of PBU
Confirmation of SW UNIT of HMU
OK
Checking the Welcome screen
NG
Confirmation of DISP Unit of HMU
(Check CN300, 400 and DISP Unit)
Confirmation of HM cable
OK
Check the images on the directly connected source 
device to PBU
NG
Check the CN5001 (HDMI connector) of PBU 
(PBU board failure)
OK
Check the sound on the directly connected source 
device to PBU
NG
Check the connection of the DAC board
OK
The confirmation of the image and audio in 
wireless connection
NG
Check the  wireless module, the HFP connection
OK
OK
Failure of the wireless module of PBU side
(Exchange and pairing of wireless RX)
Confirmation of the image and audio in the 
MHL connection
NG
Check the non-defective MHL cable
(PBU board failure)
OK
PBU/HMU OK
HMZ-T3/T3W
       
5-3
5-3. Analysis FAQ
・Operation check method
・Connect the BD recorder player or PS3 to the HDMI input
・Using the MHL cable, and connect a smart phone in the case of MHL
・Check the image visually
Partial block
Condition
Causing
How to check
Command
PU
Do not supply operation(LED is not light)
Failure of the AC adapter
I try a known-good the AC adapter
PU
Do not supply operation(LED is lit)
Failure of the Switch
Check the connection of up to  SU-1001 from FL-2005 board
PU
Do not supply operation
Failure of other
To detailed analysis
PU
Can not connect wireless
And is connected to another device with an HDMI cable to 
the HDMI connector on the Front
I disconnect the HDMI cable
PU
Can not connect wireless
Have not been paired
Check the serial No.
PU
Can not connect wireless
Wireless module failure
Pairing implementation and wireless module replacement
PU
It is not out sound from headphones
Headphone jack failure
J4001 Check
PU
FAN error
FAN failure
Radio mode ON /OFF, FAN startup check
FAN exchange
PU
The CEC pass-through does not work
Relay failure
Solder confirmation of RY1001
RY1001 exchange
PU
Without leaving HDMI images (pass-through)
HDMI connector failure
Check the CN1001-1005
PU
Without leaving HDMI image (HMD)
(Wired) HDMI connector, HDMI cable failure
HDMI connector confirmation
The change in non-defective HDMI cable
PU
Without leaving HDMI image (HMD)
(Radio) wireless module confirmation
Display confirmation of the view of the wired mode
Check the wireless mode then
PBU
Battery error
It can not communicate with the battery
Tested with battery check command
Check by replacing the normal ones in the case of abnormal
Z 84
PBU
Do not supply operation (not charging the LED will light)
Battery over discharge
Battery voltage check,
The battery replacement if there is no voltage
PBU
Do not supply operation(Charge LED is OK)
Low battery power
3 hours charging using the supplied AC adapter
PBU
Do not supply operation(Charge LED is OK)
HM cable failure
After replacing check the HM cable
PBU
Do not supply operation(Charge LED is OK)
HMU switch failure
Exchange check (MENU) SW Unit of HMU
PBU/HMU
System malfunction
HM cable failure
After replacing check the HM cable
PBU/HMU
System malfunction
The failure of the PBU board
PBU-PWB exchange after confirmation
PBU/HMU
System malfunction
The failure of the HMU board
HMU-PWB exchange after confirmation
PBU/HMU
Images do not appear (all conditions)
Dead HM Cable
After replacing check the HM cable
PBU/HMU
Images do not appear (HDMI / Wired)
Failure of the HDMI connector
Check the HDMI connector
PBU/HMU
Images do not appear on the (radio)
Failure of wireless module
Wireless module replacement after pairing implementation
PBU/HMU
Images do not appear (MHL)
Failure of MHL circuit
MHL is confirmed within 3 times insertion,
The PBU board replacement if symptoms recur
PBU/HMU
There is no sound (all conditions)
Failure of HeadPhone Jack
Checking the DAC-1001 board
PBU/HMU
There is no sound  (HDMI / Wired)
Failure of the HDMI connector
Confirmation of the HDMI connector
PBU/HMU
There is no sound  on the (radio)
Failure of wireless module
Wireless module replacement after pairing implementation
PBU/HMU
There is no sound  (MHL)
Failure of MHL circuit
MHL is confirmed within 3 times insertion,
The PBU board replacement if symptoms recur
PBU/HMU
SW is inactivity
Failure of SEN board or failure of the SW
Failure of SEN-1001 mounted sensor or SW Unit
Exchange after confirmation
PBU/HMU
Only sound not displayed image
The failure of the SEN board
After replacing the check to good SEN-1001 board
HMZ-T3/T3W
       
5-4E
5-4. Equipment you need
Equipment you need
Specification
Remarks
HDMI source device PS3, BD player, Recorder
Not Specified Model number
HDMI cable
Recommended high-speed cable within 3m
I recommend the Sony. But not specific model number
MHL source device
MHL2 compatible product or MHL1
Not Specified Model number
MHL cable
Recommended Sony DLC-MB **
I recommend the Sony. But not specific model number
TV
HDMI-compatible TV / monitor
I recommend the Sony. But not specific model number
Headphone(PU)
HP Adapter & Mini Jack HP or standard jack HP
I recommend the Sony. But not specific model number
Headphone(HMU)
HP mini jack(That you use the supplies is OK)
I recommend the Sony. But not specific model number
AC adapter
That you use the supplies(AC-UD10,AC-L200D)
Use the supplied items
USB cable
That you use the supplies
Use the supplied items
Page of 71
Display

Click on the first or last page to see other HMZ-T3 / HMZ-T3W (serv.man2) service manuals if exist.