37
Record Bias Adjustment  (Deck B)
Procedure:
INTRODUCTION
When set to the test mode performed in 
Tape Speed Adjust-
ment
,
 
when the tape is rewound after recording, the “REC memory
mode” which rewinds only the recorded portion and playback is
set.
This “REC memory mode” is convenient for performing this ad-
justment. During recording, the input signal FUNCTION will auto-
matically switch to VIDEO.
(After recording, press the  m  button without stopping will re-
turn to the position where recording was started.)
1. Press  FUNCTION  button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B, press the  REC PAUSE/START  button,
and then press the  H  button to start recording.
3. Mode: Record
5. Confirm playback the signal recorded in step 2 become adjust-
ment level as follows.
If these levels do not adjustment level, adjust the RV341 (L-CH)
and RV441 (R-CH) on the AUDIO board to repeat steps 3 and 4.
Adjustment level: The playback output of 10 kHz level difference
against 315 Hz reference should be 0 ± 0.5 dB.
Adjustment Location: AUDIO board
Record Level Adjustment  (Deck B)
Procedure:
INTRODUCTION
When set to the test mode performed in 
Tape Speed Adjust-
ment
, when the tape is rewound after recording, the “REC memory
mode” which rewinds only the recorded portion and playback is
set.
This “REC memory mode” is convenient for performing this
adjustment. During recording, the input signal FUNCTION will
automatically switch to VIDEO.
(After recording, press the  m  button without stopping will re-
turn to the position where recording was started.)
1. Press  FUNCTION  button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B, press the  REC PAUSE/START  button,
and then press the  H  button to start recording.
3. Mode: Record
4. Mode: Playback
5. Confirm playback the signal recorded in step 2 become adjust-
ment level as follows.
If these levels do not adjustment level, adjust the RV301 (L-CH)
and RV351 (R-CH) on the MAIN board to repeat steps 3 and 4.
Adjustment level:
CN301 playback level: 47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location: MAIN board
Adjustment Location:
[AUDIO BOARD]
4. Mode: Playback
[MAIN BOARD]
recorded
position
level meter
set
main board
CN301
Pin 
1
 (R-ch)
Pin 
3
 (L-ch)
AF OSC
VIDEO (AUDIO) IN
1) 315 Hz
2) 10 kHz
blank tape
CS-123
set
attenuator
600 
} 50 mV (–23.8 dB)
AF OSC
VIDEO (AUDIO) IN
315Hz 50 mV (–23.8 dB)
blank tape
CS-123
set
attenuator
600 
recorded
position
level meter
set
main board
CN301
Pin 
1
 (R-ch)
Pin 
3
 (L-ch)
CN301
IC301
RV301
Record Level (L ch)
RV351
Record Level (R ch)
3 1
RV441 RV341
RV301(Lch),RV401(Rch)
Playback Level (Deck B)
RV301 RV401
RV341(Lch),RV441(Rch)
Record Bias
RV311(Lch),RV411(Rch)
Playback Level (Deck A)
RV311
RV411
38
CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
S-Curve Check
Procedure :
1. Connect oscilloscope to TP (FEO).
2. Connect between TP (FEI) and TP (VC) by lead wire.
3. Connect between TP (AGCCON) and TP (GND) by lead wire.
4. Turn Power switch on.
5. Load a disc (YEDS-18) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
6. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 4 ±1 Vp-p.
7. After check, remove the lead wire connected in step 2 and 3.
Note :
• Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Procedure :
1. Connect oscilloscope to TP (RF).
2. Connect between TP (AGCCON) and TP (GND) by lead wire.
3. Turned Power switch on.
4. Load a disc (YEDS-18) and playback.
5. Confirm that oscilloscope waveform is clear and check RF signal
level is correct or not.
6. After check, remove the lead wire connected in step 2.
BD (CD) board
Oscilloscope
TP(FEO)
TP(VC)
symmetry
S-curve waveform
within 4 
±
1Vp-p
A
B
TP(RF)
TP(VC)
BD board
oscilloscope
Note:
Clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
E-F Balance (1 Track jump) Check
Procedure:
1. Connect oscilloscope to TP (TEO) and TP (VC) board.
2. Turned Power switch on.
3. Load a disc (YEDS-18) and playback the number five track.
4. Press the  u  button. (Becomes the 1track jump mode.)
5. Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
1 track jump waveform
Specification level:      
x
 100=less than ±22%
6. After check, remove the lead wire connected in step 1.
RF PLL Free-run Frequency
Procedure :
1. Connect frequency counter to test point (XPCK) with lead wire.
2. Turned Power switch on.
3.
Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218MHz.
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.45 
±
 0.3Vp-p
oscilloscope
BD (CD) board
TP (TEO)
TP (VC)
+
0V
Center of
waveform
B
Symmetry
A (DC voltage)
level=1.3
±
0.6Vp-p
A
B
+
frequency counter
BD (CD) board
TP (XPCK)
39
Adjustment Location :
[ BD (CD) BOARD ] — SIDE B —
TP
(VC)
TP
(RF)
TP
(TEO)
TP 
(FEO)
TP
(GND)
TP
(AGCCON)
IC102
TP
(XPCK)
40
6-1. PARTS REPLACEMENT AND ADJUSTMENT
If malfunctions caused by Optical pick-up such as sound skipping are suspected, follow the following check.
Check before replacement
Other faults are suspected.
Check the threading mechanism, etc.
Start
NG
NG
NG
OK
OK
OK
Laser Power Check
6-6-2.
(See page 43)
6-6-3.
(See page 43)
6-6-4.
(See page 44)
Iop Compare
Auto Check
Replace Optical pick-up or MDM-7B
  MD SECTION
Page of 127
Display