Sony HCD-ZTX7 / LBT-ZTX7 Service Manual ▷ View online
21
HCD-ZTX7
2-19. MOTOR (TB) BOARD
2-20. MOTOR (LD) BOARD
Remove the two solderings of motor.
MOTOR (TB) board
table motor assy (M741)
two screws
(+BTTP (M2.6))
stopper
stopper
table
wire (flat type) (5 core)
(CN742)
Remove the two solderings of motor.
MOTOR (LD) board
belt (loading)
loading motor assy (M751)
two screws
(+BTTP (M2.6))
22
HCD-ZTX7
SECTION 3
TEST MODE
3. Press [EQ BAND/MEMORY] button repeatedly until a message
“GEQ FLAT” appears on the fl uorescent indicator tube. GEQ
is set to fl at.
is set to fl at.
4. When the [MASTER VOLUME] knob is turned clockwise even
slightly, the sound volume increases to its maximum and a mes-
sage “VOLUME MAX” appears on the fl uorescent indicator
tube.
sage “VOLUME MAX” appears on the fl uorescent indicator
tube.
5. When
the [MASTER VOLUME] knob is turned counter-clock-
wise even slightly, the sound volume decreases to its minimum
and a message “VOLUME MIN” appears on the fl uorescent
indicator tube.
and a message “VOLUME MIN” appears on the fl uorescent
indicator tube.
* Tape function
1. Insert a tape in deck. The function is changed to VIDEO auto-
1. Insert a tape in deck. The function is changed to VIDEO auto-
matically when the recording is started by pressing [REC TO
TAPE] then press [ENTER] button.
TAPE] then press [ENTER] button.
2. During recording, press [m] button will stop the recording
and the function is changed to TAPE and rewind the tape in
Deck until the recording start position and playback of the tape
in Deck is started.
Deck until the recording start position and playback of the tape
in Deck is started.
* To release from MC Test mode
1. To release from this mode, press [?/1] button.
2. The cold reset is enforced at the same time.
1. To release from this mode, press [?/1] button.
2. The cold reset is enforced at the same time.
[COLD RESET]
• The cold reset clears all data including preset data stored in the
• The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning the
set to the customer.
set to the customer.
Procedure:
1. Press [x] button, [DELAY] button and [?
1. Press [x] button, [DELAY] button and [?
/1] button
simultaneously.
2. The
2. The
fl uorescent indicator tube becomes blank for while, and the
set is reset.
[VACS ON/OFF]
• This mode is used to switch ON and OFF the VACS (Variable
• This mode is used to switch ON and OFF the VACS (Variable
Attenuation Control System).
Procedure:
1. Press [?
1. Press [?
/1] button to turn on the system.
2. Press [x] button and [OPTIONS] button simultaneously. The
message “VACS OFF” or “VACS ON” appears on the fl uorescent
indicator tube.
indicator tube.
[TUNER STEP CHANGE]
• The step interval of AM channels can be toggled between 9 kHz
• The step interval of AM channels can be toggled between 9 kHz
and 10 kHz.
Procedure:
1. Press [?
1. Press [?
/1] button to turn on the system.
2. Press [TUNER/BAND] button to select the “AM”.
3. Press [?
3. Press [?
/1] button to turn off the system.
4. Press [ENTER] button and [?
/1] button simultaneously. The
system will turn on automatically. The message “AM 9K STEP”
or “AM 10K STEP” appears on the fl uorescent indicator tube
and thus the channel step is changed.
or “AM 10K STEP” appears on the fl uorescent indicator tube
and thus the channel step is changed.
[GC TEST MODE]
• This mode is used to check the fl uorescent indicator tube, LEDs,
• This mode is used to check the fl uorescent indicator tube, LEDs,
buttons, MASTER VOLUME knob, OPERATION DIAL knob,
model, destination, software version.
model, destination, software version.
Procedure:
1. Press
1. Press
[x] button, [DELAY] button and [DISC 2] button
simultaneously.
2. All LEDs and segments in fl uorescent indicator tube are lighted
2. All LEDs and segments in fl uorescent indicator tube are lighted
up.
All LEDs are lighted up in red color except for [
] LED where
the LED is lighted up in red and blue color.
3. When you want to enter to the model version and destination
display mode, press [DISC 1] button. The model information
appears on the fl uorescent indicator tube.
appears on the fl uorescent indicator tube.
4. Each
time
[DISC 1] button is pressed, the display changes to
display software version and date of the software creation. The
sequence is SC version, GC version, SYS version, CD version,
CDDM version, CDMA version, CDMB version, BDA version,
BDB version, ST version, TC version, TA version, TM version,
MM1 version, MM2 version and MTR version in this order, and
returns to the model version display.
sequence is SC version, GC version, SYS version, CD version,
CDDM version, CDMA version, CDMB version, BDA version,
BDB version, ST version, TC version, TA version, TM version,
MM1 version, MM2 version and MTR version in this order, and
returns to the model version display.
5. Press
[DISC 2] button, the key check mode is activated.
6. In the key check mode, the fl uorescent indicator tube displays
“K 0 J0 V0”.
Turn the [OPERATIONAL DIAL] clockwise; “J” value increas-
es by one. Turn the [OPERATIONAL DIAL] counterclockwise;
“J” value decreases by one. Each time a button is pressed, “K”
value increases. Press other keys on main unit to check whether
the key is detected. However, once a button has been pressed, it
is no longer taken into account.
es by one. Turn the [OPERATIONAL DIAL] counterclockwise;
“J” value decreases by one. Each time a button is pressed, “K”
value increases. Press other keys on main unit to check whether
the key is detected. However, once a button has been pressed, it
is no longer taken into account.
“V” value increases in the manner of 0, 1, 2, 3 ... if [MASTER
VOLUME] knob is turned clockwise, or it decreases in the man-
ner of 0, 9, 8, 7 ... if [MASTER VOLUME] knob is turned
VOLUME] knob is turned clockwise, or it decreases in the man-
ner of 0, 9, 8, 7 ... if [MASTER VOLUME] knob is turned
counterclockwise.
7. When [DISC SKIP/EX-CHANGE] button is pressed after all
7. When [DISC SKIP/EX-CHANGE] button is pressed after all
LEDs and segments in fl uorescent indicator tube light up, al-
ternate segments in fl uorescent indicator tube and LED would
light up. If you press [DISC SKIP/EX-CHANGE] button again,
another half of alternate segments in fl uorescent indicator tube
and LEDs would light up. Press [DISC SKIP/EX-CHANGE]
button would cause all segments in fl uorescent indicator tube
and LED turns off. Pressing [DISC SKIP/EX-CHANGE] button
again would cause all LED and segments lights up.
ternate segments in fl uorescent indicator tube and LED would
light up. If you press [DISC SKIP/EX-CHANGE] button again,
another half of alternate segments in fl uorescent indicator tube
and LEDs would light up. Press [DISC SKIP/EX-CHANGE]
button would cause all segments in fl uorescent indicator tube
and LED turns off. Pressing [DISC SKIP/EX-CHANGE] button
again would cause all LED and segments lights up.
8. To release from this mode, press three buttons in the same man-
ner as step 1, or disconnect the power cord.
[MC TEST MODE]
• This mode is used to check operations of the respective sections
• This mode is used to check operations of the respective sections
of Amplifi er, Tuner and Tape.
Procedure:
• To enter MC Test Mode
1. Press
• To enter MC Test Mode
1. Press
[x] button,[DELAY] button and [DISC 3] button
simultaneously.
2. The CD ring indicators fl ash on the fl uorescent indicator tube.
2. The CD ring indicators fl ash on the fl uorescent indicator tube.
The function is changed to VIDEO.
* Check of Amplifi er
1. Press [EQ BAND/MEMORY] button repeatedly until a message
1. Press [EQ BAND/MEMORY] button repeatedly until a message
“GEQ MAX” appears on the fl uorescent indicator tube. GEQ
increases to its maximum.
increases to its maximum.
2. Press [EQ BAND/MEMORY] button repeatedly until a message
“GEQ MIN” appears on the fl uorescent indicator tube. GEQ
decreases to its minimum.
decreases to its minimum.
23
HCD-ZTX7
[CD SERVICE MODE]
• This mode let you move the CD sled motor freely. Use this mode
• This mode let you move the CD sled motor freely. Use this mode
when you want to clean the optical pick-up.
Procedure:
1. Press [?
1. Press [?
/1] button to turn on the system.
2. Select
CD
function.
3. Press [x] button, [DELAY] button and [OPEN/CLOSE] button
simultaneously.
4. The CD service mode is activated. The message “SERVICE
MODE” appears on the fl uorescent indicator tube.
5. With the CD in stop status, press [M] to move the optical pick-
up to outside track, or turn [m] to move to inside track. The
message “SLED OUT” or “SLED IN” appears on the fl uorescent
indicator tube.
message “SLED OUT” or “SLED IN” appears on the fl uorescent
indicator tube.
6. To turn on or off the laser, press [>] button. The message “LD
ON” or “LD OFF” appears on the fl uorescent indicator tube.
7. To release from this mode, press [?
/1] button to turn off the
system.
[CD AGING MODE]
• This mode can be used for operation check of CD section. If
• This mode can be used for operation check of CD section. If
an error occurs, the aging operation would stops and the status
is displayed. If there were no error occurs, the aging operation
would continue repeatedly.
is displayed. If there were no error occurs, the aging operation
would continue repeatedly.
Procedure:
1. Press [?
1. Press [?
/1] button to turn on the system.
2. Select
CD
function.
3. Load three discs on disc tray.
4. Press [PLAY MODE/TUNING MODE] button on the remote
4. Press [PLAY MODE/TUNING MODE] button on the remote
control repeatedly to select the “ALL DISCS” mode, and press
the [REPEAT/FM MODE] button on the remode control repeat-
edly to select repeat mode off.
the [REPEAT/FM MODE] button on the remode control repeat-
edly to select repeat mode off.
5. Press [x] button, [DELAY] button and [DISC SKIP/EX-
CHANGE] button simultaneously.
6. Aging operation is started.
7. To release from this mode, press [?
7. To release from this mode, press [?
/1] button or disconnect the
power cord to turn the power OFF.
• Aging mode sequence:
DISC CHUCKING
TOC READING
PLAY FIRST TRACK FOR 2
SECONDS
OPEN THE DISC TRAY
DISC SKIP
CLOSE THE DISC TRAY
START
PLAY LAST TRACK FOR 2
SECONDS
EX-CHANGE OPEN/CLOSE
CHANGE THE NEXT DISC
24
HCD-ZTX7
[CD ERROR CODE MODE]
• Display the CD error code when an error occurred.
• Display the CD error code when an error occurred.
Procedure:
1. Press [x] button, [DELAY] button and [DISC 1] button
1. Press [x] button, [DELAY] button and [DISC 1] button
simultaneously to enter the error code display mode.
2. The
fl uorescent indicator tube display the number of total er-
ror.
3. Each
time [m] button and [M] button are turned, display
change as below.
%%
: The process when trouble occurs
01
: Process ejecting DISC
02
: Process waiting for inserting DISC
03
: Process sending request to insert a disc to upper
layer.
04
: Process sending request to eject a disc to upper
layer.
05
: Process pulling a DISC in.
06
: Chucking process
07
: Re-chucking process
08
: Process cancelling chucking
&&
: The operation when trouble occurs
00
: Waiting for operation.
10/11/12/13: During eject operation
20
: While pulling a disc in
30
: While cancelling chucking
40/41/42/43: During eject operation due to error.
0000 : Not used (Value is fi xed to 0000).
• Display of BD error. It is shown with “D” and 11 digits
number.
DISPLAY OF
TOTAL ERROR
DISPLAY OF
MECHANICAL
ERRORS
DISPLAY OF
NO DISC
ERRORS
[.] BUTTON
[
N] BUTTON
[
N]
[
N]
[.] BUTTON
[.]
[.]
[
N] BUTTON
4. To clear the error record, operate the cold reset. (Refer to the
“MC COLD RESET”.)
5. To release from this mode, press the [?
/1] button or disconnect
the power plug to turn the power OFF.
• Display of total error
Em** : The number of times for CDM (mechanical) errors.
Ed** : The number of times for BD error (after chucking the
Ed** : The number of times for BD error (after chucking the
disc.).
• Display of CDM (mechanical) error. It is show with “M” and
11 digit number.
Em**Ed**
M*$$%%&&0–
000
000
M*
: The number of history error for mechanical. (“0” is
latest one) (Turn [>] button to display next error.)
$$
: Mechanical errors occur in the operation.
FF
: Mechanical error during normal operation.
Other : Mechanical error during initializing operation.
D*$$%%&–
#00
#00
D*
: The number of error history (“0” is latest one)
(Press [>] button to display next error.)
$$
: The detail of trouble
01
: Can not focus
02
: GFS error
03
: Start-up time over
04
: Continuously out of focus
05
: Q code is not input for certain time
06
: Tracking on is impossible
07
: Blank disc
%%
: The process when trouble occurs
01
: While SHIP process is performed
02
: While POWER OFF is processed
03
: While INITIALIZE (POWER ON) is processed.
04
: While oscillation stops
05
: From stopping oscillation to start oscillation
06
: During stop
07
: During STOP operation
08
: While start-up is processed
09
: While TOC reading is processed
0a
: During search operation
0b
: During PLAY operation
0c
: During pause operation
0d
: During PLAY manual search operation
0e
: During PAUSE manual search operation
&&
: Processing operation when trouble occurs
Show each STEP mentioned in %% digits.
##
: Disc speed when trouble occurs.
01
: x1 speed
02
: x2 speed (for models which support x2 speed)
04
: x4 speed
00
: Not used (value is fi xed to 00).
Click on the first or last page to see other HCD-ZTX7 / LBT-ZTX7 service manuals if exist.