21
HCD-XG55
Tape Speed Adjustment
DECK B
Mode: Playback
1. Insert the WS-48B into the deck B.
2. Press the H button on the deck B.
3. Press the 
[H SPEED DUB]
 button in playback mode.
Then at HIGH speed mode.
4. Adjust RV1001 on the LEAF SW board do that frequency
counter reads 6,000 
±
 180 Hz.
5. Press the 
[H SPEED DUB]
 button.
Then back to NORMAL speed mode.
6. Adjust RV1002 on the LEAF SW board so that frequency
counter reads 3,000 
±
 90 Hz.
Adjustment Location: LEAF SW board
Sample value of Wow and Flutter: 0.3% or less W.RMS (JIS)
(WS-48B)
Playback Level Adjustment
DECK A      DECK B
Procedure:
Mode: Playback
Deck A is RV311 (L-CH), Deck B is RV301 (L-CH) so that ad-
justment within specification values as follows.
Specification Values:
J101 PB level: 301.5 to 338.3 mV (– 8.2 to – 7.2 dB) level
difference between the channels: within 
±
 0.5 dB
Adjustment Location: AUDIO board
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode: Playback
4. Repeat step 1 to 3 in playback (REV) mode.
5. After the adjustments, apply suitable locking compound to the
pats adjusted.
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
set
test tape
P-4-A100
(10 kHz, – 10 dB)
R-CH
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
MAIN board
MD OUT jack (J701)
L-CH
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
MAIN board
MD OUT jack (J701)
L-CH, R-CH
frequency counter
+
set
test tape
P-4-L300
(315 Hz, 0 dB)
MAIN board
MD OUT jack (J701)
L-CH
level meter
Record/Playback Head Azimuth Adjustment
Note:
 Perform this adjustments for both decks
Procedure:
1. Mode: Playback (FWD)
DECK A      DECK B
set
MAIN board
MD OUT jack (J701)
L-CH, R-CH
+
level meter
test tape
P-4-A100
(10 kHz, – 10 dB)
Adjustment Location: Playback Head (Deck A).
Record/Playback/Erase Head (Deck B).
reverse
forward
22
HCD-XG55
REC Bias Adjustment
   DECK B
Procedure:
1. Mode: Record
FUNCTION: VIDEO
2. Mode: Playback
3. Confirm playback the signal recorded in step 1 become speci-
fication values as follows.
If these values are out of specification values, adjust the RV341
(L-CH) and RV441 (R-CH) on the AUDIO board to repeat
steps 1and 2.
Specification values: Playback output of 315 Hz to playback
output of 10 kHz: 
±
 0.5 dB
Adjustment Location: AUDIO board
REC Level Adjustment
   DECK B
Procedure:
1. Mode: Record
FUNCTION: VIDEO
2. Mode: Playback
3. Confirm playback the signal recorded in step 1 become speci-
fication values as follows.
If these values are out of specification values, adjust the RV301
(L-CH) and RV351 (R-CH) on the MAIN board to repeat steps
1 and 2.
Specification values:
J101 PB level:  47.2 to 53.0 mV (– 24.3 to – 23.3 dB)
Adjustment Location: MAIN board
attenuator
set
MAIN board 
VIDEO AUDIO IN jack (J701)
L-CH, R-CH
1) 315 Hz
2) 10 kHz
50 mV (– 23.8 dB)
600 
blank tape
CN-123
AF OSC
+
set
recorded
portion
MAIN board
MD OUT jack (J701)
L-CH, R-CH
level meter
set
MAIN board
VIDEO AUDIO IN jack (J701)
L-CH, R-CH
315 Hz, 50 mV (– 23.8 dB)
blank tape
CS-123
600 
attenuator
AF OSC
+
set
recorded
portion
MAIN board
MD OUT jack (J701)
L-CH, R-CH
level meter
RV301
RV341
RV311
IC602
CN601
R L
 
RV441
PB LEVEL
 (L)
– DECK B –
REC BIAS
PB LEVEL (L)
– DECK A –
– AUDIO BOARD (Component Side) –
TAPE SPEED
RV1002
RV1001
(NORMAL)  (HIGH)
CN1001
– LEAF SW BOARD (Component Side) –
MD OUT
L/R
IC301
REC LEVEL
RV301
L-CH
RV351
R-CH
VIDEO
AUDIO IN
L/R
J701
– MAIN BOARD (Conductor Side) –
23
HCD-XG55
Note:
1. CD Block is basically designed to operate without adjustment.  There-
fore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10 M
 impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S-Curve Check
Procedure:
1. Connect oscilloscope to TP (FE) and TP (VC).
2. Connect between TP (FE1) and TP (VC) by lead wire.
3. Connect between TP (AGCCON) and TP  (GND)  by lead wire.
4. Turn the power ON.
5. Load a disc (YEDS-18) and actuate the focus search. (In con-
sequence of open and close the disc tray, actuate the focus
search)
6. Cofirm that the oscilloscope waveform (S-curve) is symmetri-
cal between A and B.  And confirm peak to peak level within
±
 1 Vp-p.
S-curve waveform
7. After check, remove the lead wire connected in step 2 and 3.
Note:
• T ry to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• T ake sweep time as long as possible and light up the brightness
to obtain best waveform.
RF  Level Check
Procedure:
1. Connect oscilloscope to TP (RF) and TP (VC).
2. Connect between TP (AGCCON) and TP (GND) by lead wire.
3. Turn the power ON.
4. Load a disc (YEDS-18) and press the
H
 
X
button to play.
5. Confirm that the oscilloscope waveform is clear and check RF
signal level is correct or not.
6. After check, remove the lead wire connected in step 2.
Note:
Clear RF signal waveform means that the shape “ ” can be clearly
distinguished at the center of the waveform.
CD SECTION
+
BD board
TP (FE)
TP (VC)
oscilloscope
A
B
symmetry
within 4 
±
 1 Vp-p
+
BD board
TP (RF)
TP (VC)
oscilloscope
(AC range)
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
(with the 10: 1 probe 
in use)
level:
1.45 
±
 0.3 Vp-p
E-F Balance (1 Track Jump) Check
Procedure :
1. Connect oscilloscpe to TP (TE) and TP (VC).
2. Turn the power ON.
3. Load a disc (YEDS-18) and playback the number five track.
4. Press the
H
 
X
button. (Becomes the 1 track jump mode)
5. Confirm that the level B and A (DC voltage) on the oscillo-
scope waveform.
1 track jump waveform
Specified level:          
×
 100 = less than 
±
 22%
6. After check, remove the lead wire connected in step 1.
Checking Location:
A
B
+
BD board
TP (TE)
TP (VC)
oscilloscope
(DC range)
A (DC voltage)
center of 
waveform
B
0V
level = 1.3 
±
 0.6 Vp-p
symmetry
– BD BOARD (Side B) –
TP (VC)
TP (FE)
TP (FE1)
TP (TE)
TP (RF)
TP (AGCCON)
TP (GND)
IC102
IC103
24
HCD-XG55
NOTE FOR PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS
Note on Printed Wiring Board:
X
: parts extracted from the component side.
Y
: parts extracted from the conductor side.
: Pattern from the side which enables seeing.
(The other layers' patterns are not indicated.)
• Indication of transistor.
Caution:
Pattern face side:
Parts on the pattern face side seen from
(Side B)
the pattern face are indicated.
Parts face side:
Parts on the parts face side seen from
(Side A)
the parts face are indicated.
B
These are omitted.
C
E
Q
B
These are omitted.
C
E
Q
C
B
These are omitted.
E
Q
Note on Schematic Diagram:
• All capacitors are in 
µ
F unless otherwise noted. pF: 
µµ
F
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise
specified.
2
: nonflammable resistor.
5
: fusible resistor.
C
: panel designation.
f
: internal component.
A
: B+ Line.
B
: B– Line.
H
: adjustment for repair.
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal produc-
tion tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal produc-
tion tolerances.
• Circled numbers refer to waveforms.
• Signal path.
F
: TUNER (FM/AM)
E
: TAPE PLAY (DECK A)
d
: TAPE PLAY (DECK B)
G
: RECORD
J
: CD PLAY (ANALOG OUT)
c
: CD PLAY (DEGITAL OUT)
N
: MIC INPUT
SECTION 7
DIAGRAMS
Note: The components identified by mark 
0
 or dotted line
with mark 
0
 are critical for safety.
Replace only with part number specified.
Page of 80
Display

Click on the first or last page to see other HCD-XG55 service manuals if exist.