DOWNLOAD Sony HCD-VZ10 Service Manual ↓ Size: 8.83 MB | Pages: 92 in PDF or view online for FREE

Model
HCD-VZ10
Pages
92
Size
8.83 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-vz10.pdf
Date

Sony HCD-VZ10 Service Manual ▷ View online

21
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location: Playback Head (Deck A)
Record/Playback/Erase Head (Deck B)
3. Mode: Playback
Tape Speed Adjustment (Deck A)
Note: Set the test mode using the following method and begin tape
speed adjustment.
In the test mode, the speed will switch to double speed or
normal speed each time the  HI-SPEED DUB  button is pressed.
Procedure:
With the power turned ON, press the  x  button,  DISPLAY  button,
and  DISC 3  button simultaneously.
(The “VOLUME” on the fluorescent display tube will blink while
in the test mode.)
To exit the test mode, press the  "/1  button.
1. Insert the WS-48B into deck B.
2. Press the  H  button of deck B.
3. Press the  HI-DUB  button and play the tape at double speed.
4. Adjust RV1001 of the LEAF SW board so that the reading of
the frequency counter becomes 6000 ± 180 Hz.
5. Press the  HI-DUB  button and play the tape at normal speed.
6. Adjust RV1002 of the LEAF SW board so that the reading of
the frequency counter becomes 3000 ± 90 Hz.
Adjustment Location: LEAF SW board
Sample Value of Wow and flutter
W.RMS (JIS) less than 0.3%
(test tape: WS-48B)
Playback Level Adjustment (Deck A,  Deck B)
Procedure:
Mode: Playback
Deck A is RV311 (L-CH) and RV411 (R-CH), deck B is RV301
(L-CH) and RV401 (R-CH)
so that adjustment within the following adjustment level.
Adjustment level:
CN301 playback level: 301.5 to 338.3 mV (–8.2 to –7.2 dB)
level difference between the channels: within ± 0.5 dB
Adjustment Location: AUDIO board
Adjustment Location
[LEAF SW BOARD]
test tape
P-4-A100
(10kHz, –10dB)
oscilloscope
set
Waveform of oscilloscope
in phase
45
°
90
°
135
°
180
°
good
wrong
Pin 2 (GND)
main board
CN301
Pin 
3 (L-ch)
Pin 1 (R-ch)
L
R
Reverse
Foward
test tape 
P-4-L300
(315Hz, 0dB)
level meter
set
main board
CN301
Pin 
1 (R-ch)
Pin 
3 (L-ch)
RV1002
RV1001
RV1002(Normal Speed)
RV1001(High Speed)
22
Record Bias Adjustment  (Deck B)
Procedure:
INTRODUCTION
When set to the test mode performed in Tape Speed Adjust-
ment
, when the tape is rewound after recording, the “REC memory
mode” which rewinds only the recorded portion and playback is
set.
This “REC memory mode” is convenient for performing this ad-
justment. During recording, the input signal FUNCTION will auto-
matically switch to VIDEO.
(After recording, press the  m  button without stopping will re-
turn to the position where recording was started.)
1. Press  FUNCTION  button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B, press the  REC PAUSE/START  button,
and then press the  H  button to start recording.
3. Mode: Record
5. Confirm playback the signal recorded in step 2 become adjust-
ment level as follows.
If these levels do not adjustment level, adjust the RV341 (L-CH)
and RV441 (R-CH) on the AUDIO board to repeat steps 3 and 4.
Adjustment level: The playback output of 10 kHz level difference
against 315 Hz reference should be ± 1.0 dB.
Adjustment Location: AUDIO board
Record Level Adjustment  (Deck B)
Procedure:
INTRODUCTION
When set to the test mode performed in Tape Speed Adjust-
ment
, when the tape is rewound after recording, the “REC memory
mode” which rewinds only the recorded portion and playback is
set.
This  “REC memory mode” is convenient for performing this
adjustment. During recording, the input signal FUNCTION will au-
tomatically switch to VIDEO.
(After recording, press the  m  button without stopping will re-
turn to the position where recording was started.)
1. Press  FUNCTION  button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B, press the  REC PAUSE/START  button,
and then press the  H  button to start recording.
3. Mode: Record
4. Mode: Playback
5. Confirm playback the signal recorded in step 2 become adjust-
ment level as follows.
If these levels do not adjustment level, adjust the RV301 (L-CH)
and RV351 (R-CH) on the MAIN board to repeat steps 3 and 4.
Adjustment level:
CN301 playback level: 47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location: MAIN board
Adjustment Location:
[AUDIO BOARD]
4. Mode: Playback
[MAIN BOARD]
recorded
position
level meter
set
main board
CN301
Pin 
1 (R-ch)
Pin 
3 (L-ch)
AF OSC
VIDEO (AUDIO) IN
1) 315 Hz
2) 10 kHz
blank tape
CS-123
set
attenuator
600 
} 50 mV (–23.8 dB)
AF OSC
VIDEO (AUDIO) IN
315Hz 50 mV (–23.8 dB)
blank tape
CS-123
set
attenuator
600 
recorded
position
level meter
set
main board
CN301
Pin 
1 (R-ch)
Pin 
3 (L-ch)
CN301
IC301
RV301
Record Level (L ch)
RV351
Record Level (R ch)
3 1
RV441 RV341
RV301(Lch),RV401(Rch)
Playback Level (Deck B)
RV301 RV401
RV341(Lch),RV441(Rch)
Record Bias
RV311(Lch),RV411(Rch)
Playback Level (Deck A)
RV311
RV411
23
CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
Ω impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
S-Curve Check
Procedure :
1. Connect oscilloscope to TP (FEO).
2. Connect between TP (FEI) and TP (VC) by lead wire.
3. Connect between TP (AGCCON) and TP (GND) by lead wire.
4. Press the  "/1  button to turn ON the power.
5. Load a disc (YEDS-18) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
6. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 4 ±1 Vp-p.
7. After check, remove the lead wire connected in step 2 and 3.
Note : • Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Procedure :
1. Connect oscilloscope to TP (RF).
2. Connect between TP (AGCCON) and TP (GND) by lead wire.
3. Press the  "/1  button to turn ON the power.
4. Load a disc (YEDS-18) and playback.
5. Confirm that oscilloscope waveform is clear and check RF signal
level is correct or not.
6. After check, remove the lead wire connected in step 2.
BD board
Oscilloscope
TP(FEO)
TP(VC)
symmetry
S-curve waveform
within 4 
±1Vp-p
A
B
TP(RF)
TP(VC)
BD board
oscilloscope
Note: Clear RF signal waveform means that the shape “
◊” can be
clearly distinguished at the center of the waveform.
RF signal waveform
E-F Balance (1 Track jump) Check
Procedure:
1. Connect oscilloscope to TP (TEO) and TP (VC) board.
2. Press the  "/1  button to turn ON the power.
3. Load a disc (YEDS-18) and playback the number five track.
4. Press the  u  button. (Becomes the 1track jump mode.)
5. Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
1 track jump waveform
Specification level:      x 100=less than ±22%
6. After check, remove the lead wire connected in step 1.
RF PLL Free-run Frequency
Procedure :
1. Connect frequency counter to test point (XPCK) with lead wire.
2. Press the  "/1  button to turn ON the power.
3. Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218MHz.
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.45 
± 0.3Vp-p
oscilloscope
BD board
TP (TEO)
TP (VC)
+
0V
Center of
waveform
B
Symmetry
A (DC voltage)
level=1.3
±0.6Vp-p
A
B
+
frequency counter
BD board
TP (XPCK)
24
  VIDEO SECTION
Frequency adjustment
1. Connect the frequency counter to check point of the VIDEO
board.
2. Adjust CT503 of the VIDEO board so that the frequency counter
read 27MHz ± 80Hz at STOP condition.
[ VIDEO BOARD ] – SIDE B –
Adjustment Location :
[ VIDEO BOARD ] – SIDE A –
frequency counter
VIDEO board
(27 MHz)
+
SL501
IC502
SL502
SL503
TEST
MODE
SL501 SL502
CT503
SL503
TEST MODE
VIDEO
FREQUENCY
(27MHz)
(GND)
IC507
IC505
Adjustment Location :
[ BD BOARD ] — SIDE B —
TP
(VC)
TP
(RF)
TP
(TEO)
TP
(IOP)
TP 
(FEO)
TP
(AGND)
TP
(DGND)
TP
(AGCCON)
IC102
Page of 92