DOWNLOAD Sony HCD-VX5AJ / MHC-VX5 / MHC-VX5J / MHC-VX7 Service Manual ↓ Size: 7.94 MB | Pages: 86 in PDF or view online for FREE

Model
HCD-VX5AJ MHC-VX5 MHC-VX5J MHC-VX7
Pages
86
Size
7.94 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / S/M HCD-VX5A/VX5AJ/VX7A 99
File
hcd-vx5aj-mhc-vx5-mhc-vx5j-mhc-vx7.pdf
Date

Sony HCD-VX5AJ / MHC-VX5 / MHC-VX5J / MHC-VX7 Service Manual ▷ View online

– 13 –
SECTION  4
TEST  MODE
[MC Cold Reset]
• The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning
the set to the customer.
Procedure:
1. Turn the power ON or set to the DEMO mode.
2. Press three buttons of
p , 
[ENTER/NEXT]
, and
1/
u
 simulta-
neously.
3. The set is reset, and displays “COLD RESET”, then becomes
DEMO mode.
[MC Hot Reset]
• This mode resets the set with the preset data kept stored in the
memory. The hot reset mode functions same as if the power
cord is plugged in and out.
Procedure:
1. Turn the power ON or set to the DEMO mode.
2. Press three buttons of
p , 
[ENTER/NEXT]
, and 
[DISC 1]
 si-
multaneously.
3. The set is reset, and becomes standby state.
[Change-over the AM Tuning Interval]
(EXCEPT Saudi Arabia model)
• The AM tuning interval can be changed over 9 kHz or 10 kHz.
Procedure:
1. Press the
1/
u
button to turn the power ON.
2. Select the function “TUNER”, and press the 
[TUNER/BAND]
button to select the BAND “AM (MW)”.
3. Press the
1/
u
button to turn the power OFF.
4. Press the 
[ENTER/NEXT]
 and
1/
u
buttons simultaneously,
and the display on the fluorescent indicator tube changes to
“AM 9 k STEP” or “AM 10 k STEP”, and thus the tuning
interval is changed over.
[CD Delivery Mode]
• This mode moves the optical pick-up to the position durable to
vibration. Use this mode when returning the set to the customer
after repair.
Procedure:
1. Press the
1/
u
button to turn the power ON.
2. Press the 
[CD LOOP]
 and
1/
u
buttons simultaneously.
3. A message “LOCK” is displayed on the fluorescent indicator
tube, and the CD delivery mode is set.
[LED and Fluorescent Indicator Tube All Lit, Key Check
Mode]
Procedure:
1. Press three buttons of
p , 
[ENTER/NEXT]
, and 
[DISC 2]
 si-
multaneously.
2. LEDs and fluorescent indicator tube are all turned on.
Press the 
[DISC 2]
 button, and the key check mode is acti-
vated.
3. In the key check mode, the fluorescent indicator tube displays
“K 0 J0 V0”. Each time a button is pressed, “K” value in-
creases. However, once a button is pressed, it is no longer taken
into account.
“J” value increases like 1, 2, 3 ... if turn the JOG dial clock-
wise, or it decreases like 0, 9, 8 ... if turn the JOG dial counter-
clockwise.
“V” value increases like 1, 2, 3 ... if turn the 
[VOLUME]
 dial
clockwise, or it decreases like 0, 9, 8 ... if turn the JOG dial
counterclockwise.
4. To exit from this mode, press three buttons in the same man-
ner as step 1, or disconnect the power cord.
– 14 –
[Aging Mode]
This mode can be used for operation check of tape deck section.
Tape deck section work in parallel.
• If an error occurred:
The aging operation stops and display then status.
• If no error occurs:
The aging operation continues repeatedly.
Procedure:
1. Load the tapes into the decks A and B respectively.
2. Press the 
[FUNCTION]
 button to select the function “CD”.
3. Press the 
[PLAY MODE]
 button to set the “ALL DISCS” mode,
and press the 
[REPEAT]
 button to “REPEAT” off.
4. Press three buttons of
p  , 
[ENTER/NEXT]
, and 
[DISC SKIP/
EX-CHANGE]
 simultaneously.
5. The aging mode is activated, if the indicator of disc tray num-
ber on the fluorescent indicator tube is blinking.
6. To exit from the aging mode, press the
1/
u
button to turn the
power OFF and operate the cold reset. (Refer to the “MC Cold
Reset”)
1. Display at the Aging Mode
• Display operating state of tape deck section alternately.
• If an error occurred, stop display.
2. Tape Deck Section
• The sequence during the aging mode is following as below.
• If an error occurred, stop display that step.
Aging mode sequence (Tape deck section) :
Rewind the tape A and B
“TAPE A AG-1”
Shut off
FWD play the tape A
“TAPE A AG-2”
2 minutes
Fast forward the tape A
“TAPE A AG-3”
Shut off or 20 seconds
REV play the tape A
“TAPE A AG-4”
2 minutes
Rewind the tape A
“TAPE A AG-5”
Shut off
FWD play the tape B
“TAPE B AG-2”
2 minutes
Fast forward the tape B
“TAPE B AG-3”
Shut off or 20 seconds
REV play the tape B
“TAPE A AG-4”
2 minutes
Rewind the tape B
“TAPE B AG-5”
Shut off
Note:
 “TAPE 
*
 AG-
*
” is display of each step.
– 15 –
[VIDEO CD Color-bars Mode]
On this mode, the data of the color-bars signal as a picture signal
and the 1 kHz sine wave signal as a sound signal are output by the
mechanism controller (IC502) for the video CD signal check.
When measurement of the voltage and waveform on the VIDEO
board, perform it in this mode.
For reference, the color-bars signal can be observed at J302
(VIDEO OUT) and the sound signal can be observed at J101
(VIDEO/MD (AUDIO) OUT) using an oscilloscope.
Procedure:
1. Short the both ends of the land of SL503 of the VIDEO board.
2. Turn the power on. Press the 
[FUNCTION]
 button to select
CD.
3. The color-bars appears when the CD is in stop status, and it
disappears when the CD goes in play status.
4. After measuring, remove the lead wire connected.
– VIDEO board (Side A) –
– VIDEO board (Side B) –
D502
SL501
SL503
SL502
IC505
SL503
IC502
CN501
CN503
SL502
SL501
– 16 –
SECTION  5
MECHANICAL  ADJUSTMENTS
SECTION  6
ELECTRICAL  ADJUSTMENTS
1. Demagnetize the record/playback head with a head demagne-
tizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in
this service manual.  (As a general rule, playback circuit ad-
justment should be completed before performing recording
circuit adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless other-
wise specified.
8. Set to  the DOLBY NR OFF.
9. Set to the test mode.
(1) Press the
1/
u
button to turn the power ON.
(2) Select the function “TAPE A or B”.
(3) Press the button of
p , 
[ENTER/NEXT]
, and 
[DISC 3]
simultaneously, to set the tape deck test mode and blink
the indicator of disc tray number on the fluorescent indi-
cator tube.
(4) To exit from the test mode, press the
1/
u
button.
• Test Tape
Record/Playback Head Azimuth Adjustment
Note:
 Perform this adjustments for both decks
Procedure:
1. Mode: Playback (FWD)
Tape
Signal
Used for
P-4-A100
10 kHz, – 10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
P-4-L300
315 Hz, 0 dB
Level Adjustment
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
2 to 6 g • cm
(0.03 – 0.08 oz • inch)
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
2 to 6 g • cm
(0.03 – 0.08 oz • inch)
71 to 143 g • cm
(0.99 – 1.99 oz • inch)
100 g or more
(3.53 oz or more)
100 g or more
(3.53 oz or more)
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
Mode
FWD
Torque meter
CQ-102C
Meter reading
FWD
back tension
REV
REV
back tension
FF/REW
FWD tension
REV tension
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
0 dB = 0.775 V
DECK  SECTION
DECK A      DECK B
set
MAIN board
MD OUT jack (J101)
L-CH, R-CH
+
level meter
test tape
P-4-A100
(10 kHz, – 10 dB)
Page of 86
Display

Click on the first or last page to see other HCD-VX5AJ / MHC-VX5 / MHC-VX5J / MHC-VX7 service manuals if exist.