DOWNLOAD Sony HCD-VP1 Service Manual ↓ Size: 4.86 MB | Pages: 52 in PDF or view online for FREE

Model
HCD-VP1
Pages
52
Size
4.86 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-vp1.pdf
Date

Sony HCD-VP1 Service Manual ▷ View online

9
2
Install the drive gear with gear
position as shown in figure.
gear
front side
1
Install the control cam
with gear position as shown
in figure.
gear
front side
3
screw
(PTPWH2.6 
×
 16)
5
two screws
(PTPWH2.6 
×
 7)
4
sub chassis
• SUB  CHASSIS  INSTALLATION
Note:
 Follow the assembly procedure in the numerical order given.
10
SECTION  3
SERVICE  MODE
[Liquid Crystal Display All Lit Check Mode]
Procedure:
1. Set to standby state.
2. Press three buttons of
p (TAPE), p  (CD), and 
[MD/VIDEO]
simultaneously.
3. Liquid crystal display are all turned on.
4. To release from this mode, press the
1/
u
button to turn the
power OFF.
[Tape Deck Aging Mode]
This mode can be used for operation check of tape deck section.
Procedure:
1. Set a tape in the tape deck.
2. Set to standby state.
3. Press three buttons of
p (TAPE), p (CD), and 
[TAPE]
 si-
multaneously.
4. The aging is executed in bellow sequence.
5. To release from the aging mode, press the
1/u button to turn
the power OFF.
Aging mode sequence:
[CD Aging Mode]
This mode can be used for operation check of CD section.
Procedure:
1. Load a CD disc.
2. Set to standby state.
3. Press three buttons of
p (TAPE), p (CD), and 
[TUNER]
simultaneously.
4. The aging is executed in bellow sequence.
5. To release from the aging mode, press the
1/
u
button to turn
the power OFF.
Aging mode sequence:
Start
REC pause for 3 seconds
FWD REC
Fast forward
REV Play
REC pause for 3 seconds
REV REC
Rewind
FWD Play
Shut off
Shut off
Shut off
Shut off
1 minute
3 minutes
1 minute
3 minutes
Start
Open the disc tray
Close the disc tray
Play the last track
11
Note:
Confirm each contents of this section first of all. If the results are
not satisfied, do the adjustment.
1. Demagnetize the record/playback head with a head demagne-
tizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in
this service manual.  (As a general rule, playback circuit ad-
justment should be completed before performing recording
circuit adjustment)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless other-
wise specified.
• Test Tape
Record/Playback Head Azimuth Adjustment
Procedure:
1. Mode:  Playback
SECTION  4
ELECTRICAL  CONFIRMATIONS  AND  ADJUSTMENTS
0 dB=0.775 V
DECK  SECTION
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
P-4-L300
315 Hz, 0 dB
Level Adjustment
set
MAIN board
LINE OUT jack (PJ301)
L-CH, R-CH
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode: Playback
4. Repeat step 1 to 3 in playback (REV) mode.
5. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location:
test tape
P-4-A100
(10 kHz, –10 dB)
R-CH
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
MAIN board
LINE OUT jack (PJ301)
L-CH
set
forward
reverse
12
Playback level Confirmation and Adjustment
Procedure:
Mode: Playback
Confirm playback level is within specification values as follows.
If these levels are out of specification values, adjust the RV151
(L-CH) and RV251 (R-CH) on the MAIN board so that the level
meter reading become within specified value.
Specified value:
PJ301 PB level:  301.5 to 338.3 mV (–8.2 to  –7.2 dB) level differ-
ence between the channels:  within ±0.5 dB
Adjustment Location:  MAIN board
REC Bias Confirmation and Adjustment
Procedure:
1. Mode:  Record
2. Mode:  Playback
3. Confirm playback the signal recorded in step 1 become speci-
fied value as follows.
If these values are out of specification values, adjust the RV153
(L-CH) and RV253 (R-CH) on the MAIN board to repeat steps
1and 2.
Specified value: Playback output of 315 Hz to playback output
of 10 kHz: ± 0.5 dB
Adjustment Location:  MAIN board
+
set
test tape
P-4-L300
(315 Hz, 0 dB)
MAIN board
LINE OUT jack (PJ301)
L-CH, R-CH
level meter
REC Level Confirmation and Adjustment
Procedure:
1. Mode:  Record
2. Mode:  Playback
3. Confirm playback the signal recorded in step 1 become speci-
fied value as follows.
If these values are out of specification values, adjust the RV252
(R-CH) and RV152 (L-CH) on the MAIN board to repeat steps
1 and 2.
Specified value:
PJ301 PB level:  47.2 to 53.0 mV (– 24.3 to – 23.3 dB)
Adjustment Location:  MAIN board
– MAIN  Board (Conductor Side) –
attenuator
set
MAIN board 
MD IN jack (PJ301)
L-CH, R-CH
1) 315 Hz
2) 10 kHz
50 mV (–23.8 dB)
600 
blank tape
CN-123
AF OSC
+
set
recorded
portion
MAIN board
LINE OUT jack (PJ301)
L-CH, R-CH
level meter
set
MAIN board
MD IN jack (PJ301)
L-CH, R-CH
315 Hz, 50 mV (–23.8 dB)
blank tape
CS-123
600 
attenuator
AF OSC
+
set
recorded
portion
MAIN board
LINE OUT jack (PJ301)
L-CH, R-CH
level meter
PJ301
Playback Level
REC Bias
REC Level
RV252 (R)
IC352
LINE OUT (L/R)
MD IN (L/R)
VIDEO IN (L/R)
RV152 (L)
RV251 (R)
RV151 (L)
RV253 (R)
RV153 (L)
Page of 52
Display

Click on the first or last page to see other HCD-VP1 service manuals if exist.