– 17 –
3. Mode:  Playback (FWD)
4. Repeat setps 1 to 3 in playback (REV) mode.
5. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Playback Head (Deck A).
 Record/Playback/Erase Head (Deck B).
Tape Speed Adjustment
DECK B
Note:
Start the Tape Speed adjustment as below after setting to the test
mode.
In the test mode, the tape speed is high during pressing the
[HI-DUB]
 button.
Procedure:
1. Turn the power switch on.
2. Press the
p
button, 
[ENTER/NEXT]
 button and 
[DISC 3]
 button
simultaneously.
(The “VOLUME” on the fluorescent indicator tube will blink
while in the test mode.)
To exit from the test mode, press the
I/
u
button.
Mode:  Playback
1. Insert the WS-48B into the deck B.
2. Press the
· button on the deck B.
3. Press the 
[HI-DUB]
 button in playback mode.
Then at HIGH speed mode.
4. Adjust RV1001 on the LEAF SW board do that frequency
counter reads 6,000 ± 180 Hz.
5. Press the 
[HI-DUB]
 button.
Then back to NORMAL speed mode.
6. Adjust RV1002 on the LEAF SW board so that frequency
counter reads 3,000 ± 90 Hz.
Adjustment Location:  LEAF SW board
Sample value of Wow and Flutter: 0.3% or less W.RMS (JIS)
(WS-48B)
Playback level Adjustment
DECK A
DECK B
Procedure:
Mode:  Playback
Deck A is RV311 (L-CH) and RV411 (R-CH), Deck B is RV301
(L-CH) and RV401 (R-CH) so that adjustment within adjustment
level as follows.
Adjustment Level:
CN301 PB level:  301.5 to 338.3 mV (–8.2 to  –7.2 dB) level
difference between the channels: within ± 0.5 dB
Adjustment Location:  AUDIO board
set
test tape
P-4-A100
(10 kHz, –10 dB)
(pin 
3
: R-CH)
oscilloscope
V
H
waveform of oscilloscope
in phase 45 
°
90 
°
135 
°
180 
°
good
wrong
(pin 
2
: GND)
(pin 
1
: L-CH)
MAIN board
CN301
Reverse
Foward
1
Remove the four claws
2
Window
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
MAIN board
CN301 (Pin 
1
 : L-CH)
(Pin 
3
 : R-CH)
frequency counter
+
set
test tape
P-4-L300
(315 Hz, 0 dB)
MAIN board
CN301 (Pin 
1
: L-CH)
(Pin 
3
: R-CH)
level meter
– 18 –
REC Bias Adjustment
   DECK B
Procedure:
INTRODUCTION
When set to the test mode performed in 
Tape Speed Adjustment
,
when the tape is rewound after recording, the “REC memory mode”
which rewinds only the recorded portion and playback is set.
This  “REC memory mode” is convenient for performing this ad-
justment. During recording, the input signal FUNCTION will au-
tomatically switch to VIDEO.
(After recording, press the  – 
0 button without stopping will
return to the position where recording was started.)
1. Press 
[FUNCTION]
 button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B.
3. After press 
[    REC]
 button, press
P button, then recording
start.
4. Mode:  Record
5. Mode:  Playback
6. Confirm playback the signal recorded in step 3 become ad-
justable level as follows.
If these levels do not adjustable level, adjustment the RV341
(L-CH) and RV441 (R-CH) on the AUDIO board to repeat
steps 4 and 5.
Adjustable level: Playback output of 315 Hz to playback output
of 10 kHz: ± 1.0 dB
Adjustment Location:  AUDIO board
REC Level Adjustment
   DECK B
Procedure:
INTRODUCTION
When set to the test mode performed in 
Tape Speed Adjustment
,
when the tape is rewound after recording, the “REC memory mode”
which rewinds only the recorded portion and playback is set.
This  “REC memory mode” is convenient for performing this ad-
justment. During recording, the input signal FUNCTION will au-
tomatically switch to VIDEO.
(After recording, press the  – 
0 button without stopping will
return to the position where recording was started.)
1. Press 
[FUNCTION]
 button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B.
3. After press 
[    REC]
 button, press
P button, then recording
start.
4. Mode: Record
5. Mode:  Playback
6. Confirm playback the signal recorded in step 3 become ad-
justable level as follows.
If these levels do not adjustable level, adjustment the RV301
(L-CH) and RV351 (R-CH) on the MAIN board to repeat steps
4 and 5.
Adjustable level:
CN301 PB level:  47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location:  MAIN board
Adjustment Location:
[MAIN  Board] (Component Side)
[AUDIO  Board]  (Component Side)
[LEAF  SW  Board]  (Component Side)
r
r
attenuator
+
+
+
set
MD/VIDEO (AUDIO) IN
1) 315 Hz
2) 10 kHz
50 mV (–23.8 dB)
600 
blank tape
CN-123
AF OSC
+
set
recorded
portion
MAIN board
CN301 (Pin 
1
: L-CH)
(Pin 
3
: R-CH)
level meter
set
MD/VIDEO (AUDIO) IN
315 Hz, 50 mV (–23.8 dB)
blank tape
CS-123
600 
attenuator
AF OSC
+
+
+
+
set
recorded
portion
MAIN board
CN301 (Pin 
1
: L-CH)
(Pin 
3
: R-CH)
level meter
RV301
L
REC LEVEL
RV351
R
IC301
CN301
1      3
RV401
RV301
RV341
RV311
RV411
IC602
CN601
L
R
R L
 
 
RV441
PB LEVEL
– DECK B –
REC BIAS
L
R
 
PB LEVEL
– DECK A –
TAPE SPEED
RV1002
RV1001
(NORMAL)  (HIGH)
CN1001
– 19 –
CD SECTION
Notes:
1. CD block basically constructed to operate without adjustment.  There-
fore, check each item in order given.
2. Use YEDS-18 disc (Part No.: 3-702-101-01) unless otherwise indicated.
3. Use the oscilloscope with more than 10 M
 impedance.
4. Clean an object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S-Curve Check
Connection:
Procedure:
1. Connect the oscilloscope to TP (FE) and TP (VC) on BD board.
2. Connect between test point TP (FOK) and GND by lead wire.
3. Turned power switch on.
4. Put disc (YEDS-18) in and turned power switch on again and
actuate the focus search.  (actuate the focus search when disc
table is moving in and out.)
5. Confirm that the oscilloscope waveform (S-curve) is symmetri-
cal between A and B.  And confirm peak to peak level within
3.0 ± 1.0 Vp-p.
S-curve waveform
6. After check, remove the lead wire connected in step 2.
Note:
• Try to measure several times to make sure that the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the brightness
to obtain best waveform.
RF Level Check
Connection:
Procedure:
1. Connect the oscilloscope to TP (RF) and TP (VC) on BD board.
2. Turned power switch on.
3. Put disc (YEDS-18) in and press the 
fl  button.
4. Confirm that the oscilloscope waveform is clear and check RF
signal level is correct or not.
Note:
Clear RF signal waveform means that the shape “≈” can be clearly
distinguished at the center of the waveform.
within 3.0 ± 1.0 Vp-p
RF signal waveform
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
+
BD board
TP (FE)
TP (VC)
oscilloscope
A
B
symmetry
+
BD board
TP (RF)
TP (VC)
oscilloscope
(AC range)
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
(with the 10: 1 probe 
in use)
level: 1.3        Vp-p
+0.25
–0.20
E-F Balance (Traverse) check
Connection:
Procedure:
1. Short-circuit SL502 of the VIDEO board to GND.
2. Connect oscilloscope to test point TP (TE) on BD board.
3. Turned Power switch on. Press 
[FUNCTION]
 button to select
CD.
4. Put disc (YEDS-18) in to play the number five track.
5. Press the 
[PLAY MODE]
 button.
 (The tracking servo and the sledding servo are turned OFF.)
6. Check the level B of the oscilloscope’s waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following:
Traverse waveform
7. Press the 
[PLAY MODE]
 button. (The tracking servo and sled-
ding servo are turned ON.) Confirm the C (DC voltage) is al-
most equal to the A (DC voltage) is step 6.
Traverse waveform
8. Desolder the short-land (SL502) short-circuited at step 1.
A    
×
 100 = less than ± 22 (%)
B
level: 1.3 ± 0.6 Vp-p
+
BD board
TP (TE)
TP (VC)
oscilloscope
A (DC 
voltage)
B
0 V
Center of the waveform
C (DC 
voltage)
0 V
Tracking servo
Sled servo
OFF
Tracking servo
Sled servo
ON
– 20 –
Connection Location:
[BD  Board] (Side A)
CN102
CN101
IC103
IC101
TP
(FOK)
TP
(TE)
TP
(FE)
TP (RF)
TP (VC)