– 17 –
VIDEO CD COLOR BAR MODE
On this mode, the data of the color bar signal as a picture signal
and the 1 kHz sine wave signal as a sound signal are output by the
mechanism controller (IC701) for the video CD signal check.
When measurement of the voltage and waveform on the VIDEO
board, perform it in this mode.
For reference, the color bar signal can be observed at J9001
(VIDEO OUT) and the sound signal can be observed at J101
(VIDEO (AUDIO) OUT) using an oscilloscope.
Procedure:
1. Turned power switch on.
2. Press the  FUNCTION  button to select the CD.
3. Connect the SL701 on the VIDEO board with solder.
4. After measuring, remove the soldering installed.
+
oscilloscope
75 
set
J9001 (VIDEO OUT)
B
H
C
A
A = 0.9 to 1.1 Vp-p
B = 0.678 to 0.75 Vp-p
C = 0.214 to 0.328 Vp-p
Fig. 1 Video CD Color Bar Signal Output from J9001
(VIDEO OUT)
[VIDEO BOARD]
 (SIDE-B)
E-F BALANCE MODE
Refer to the SECTION 6 ELECTRICAL ADJUSTMENTS page
21.
Procedure:
1. Turned power switch on.
2. Press the  FUNCTION  button to select the CD.
3. Connect the SL701 and SL703 on the VIDEO board with sol-
der.
4. Press the  
· button in playback.
5. Every pressing the  REPEAT  button, the tracking servo and
sledding servo are turned on or off.
6. When the servo is off, the counter on front panel will not be
changed.
7. After measuring, remove the soldering installed.
SL702
SL701
IC751
SL703
IC251
– 18 –
1. Demagnetize the record/playback head with a head demagne-
tizer.  (Do not bring the head demagnetizer close to the erase
head.)
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjust-
ment should be completed before performing recording circuit
adjustment.)
6. The adjustments should be performed for both L-CH and R-ch.
7. Switches and controls should be set as follows unless otherwise
specified.
8. Set to test mode.  (Press key switch same time
GROOVE   ENTER/NEXT and  DISC 4 buttons.)
To exit from the test mode, press the POWER button.
SECTION  4
MECHANICAL  ADJUSTMENTS
SECTION  5
ELECTRICAL  ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab:
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power  sup-
ply voltage unless otherwise noted.
Torque Measurement
Mode
Torque Meter
Meter Reading
Forward
CQ-102C
36 to 61g•cm
(0.50 – 0.84 oz•inch)
Forward
CQ-102C
2 to 6g•cm
Back Tension
(0.026 – 0.082 oz•inch)
Reverse
CQ-102RC
36 to 61g•cm
(0.50 – 0.84 oz•inch)
Reverse
CQ-102RC
2 to 6g•cm
Back Tension
(0.026 – 0.082 oz•inch)
FF, REW
CQ-201B
61 to 143g•cm
(0.85 – 1.98 oz•inch)
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 100 g (3.53 oz)
Reverse
CQ-403R
more than 100 g (3.53 oz)
DECK  SECTION
0 dB=0.775 V
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
P-4-L300
315 Hz, 0 dB
Level Adjustment
Record/Playback Head Azimuth Adjustment
set
MAIN board
CN207
pin 
3
 (L-CH)
pin 
1
 (R-CH)
MAIN board
CN207
pin 
2
 (GND)
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
Tape Tension Measurement
• Test Tape
DECK A
DECK B
Note:  Perform this adjustments for both decks.
Procedure:
1. Mode:  Playback (FWD)
Screw
position
L-CH
peak
within
1 dB
output
level
L-CH
peak
R-CH
peak
within
1 dB
Screw
position
R-CH
peak
2. Turn the adjustment screw and check output peaks.  If the peaks
do not match for L-CH and R-CH, turn the adjustment screw so
that outputs match within 1 dB of peak.
– 19 –
1. Insert the WS-48B into the deck A and the blank tape into the
deck B.
2. Press the
r REC button and · button on the deck B.  Then
the deck B is at recording mode.
3. Set the deck A to playback mode.
4. Keep pressing the H SPEED DUB button in playback mode.
Then at high speed mode.
5. Adjust RV652 on the AUDIO board so that frequency counter
reads 6,000 ± 90 Hz.
6. Take off the H SPEED DUB button.
Then at normal speed mode.
7. Adjust RV651 on the AUDIO  board so that frequency counter
reads 3,000 ± 90 Hz.
8. Frequency difference between deck A and deck B the begin-
ning of the tape should be within ± 1.5 %.
Adjustment Location:  AUDIO board (See page 20)
Sample Value of Wow and Flutter:  0.3% or less W.RMS
(WS-48B)
Tape Speed Adjustment
DECK  A
Note: Start the Tape Speed adjustment as below after setting to the test
mode.
In the test mode, the tape speed is high during pressing the
 H SPEED DUB button.
Procedure:
1. Turn the power switch on.
2. Press the GROOVE button, ENTER/NEXT button and
  DISC 4  button simultaneously.
To exit from the test mode, press the POWER button.
Mode:  Playback (FWD)
+
set
test tape
P-4-L300
(315 Hz, 0 dB)
MAIN board
CN207 (pin 
3
: L-CH)
(pin 
1
: R-CH)
level meter
3. Mode:  Playback (FWD)
4. Repeat steps 1 to 3 in playback (REV) mode.
5. After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location: Playback Head (Deck A)
Record/Playback Head (Deck B)
Deck A is RV311 (L-CH) and RV411 (R-CH), Deck B is RV301
(L-CH) and RV401 (R-CH) so that adjustment within adjustment
level as follows.
Adjustment Level:
CN207 PB level:  301.5 to 338.3 mV (– 8.2 to  – 7.2 dB) level
difference between the channels:  within ± 0.5 dB
Adjustment Location:  AUDIO board (See page 20)
set
test tape
P-4-A100
(10 kHz, –10 dB)
pin 
1
 (R-CH)
oscilloscope
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
pin 
2
 (GND)
pin 
3
 (L-CH)
MAIN board
CN207
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
MAIN board
CN207 (pin 
3
 : L-CH)
     (pin 
1
 :R-CH)
frequency counter
Playback level Adjustment
DECK A
DECK B
Procedure:
Mode:  Playback (FWD)
reverse
forward
– 20 –
+
set
recorded
portion
MAIN board
CN207 (pin 
3
: L-CH)
(pin 
1
: R-CH)
level meter
attenuator
set
pin 
6
 (L-CH) of IC1501 on the MAIN board.
pin 
 (R-CH) of IC1501 on the MAIN board.
1) 315 Hz
2) 10 kHz
50 mV (–23.8 dB)
pin 
2
 (GND) of CN207 on the MAIN board.
600 
blank tape
CS-123
AF OSC
RV1501
IC1501
CN205
CN207
RV1551
RECORD LEVEL
IC301
IC201
1
21
1
22
42
3
Record bias Current Adjustment
DECK B
Procedure:
1. Mode:  Record
2. Mode:  Playback
+
set
recorded
portion
MAIN board
CN207 (pin 
3
: L-CH)
(pin 
1
: R-CH)
level meter
Confirm playback the signal recorded in step 1 become adjustable
limits as follows.
If these levels do not adjustable limits, adjustment the RV341 (L-
CH) and RV441 (R-CH) on the AUDIO board to repeat steps 1
and 2.
Adjustable limits: Playback output of 315 Hz to playback out-
put of 10 kHz:  ±0.5 dB
Adjustment Location:  AUDIO board
Record Level Adjustment   DECK B
Procedure:
1. Mode:  Record
2. Mode:  Playback
Confirm playback the signal recorded in step 1 become adjustable
limits as follows.
If these levels do not adjustable limits, adjustment the RV1501 (L-
CH) and RV1551 (R-CH) on the MAIN board to repeat steps 1
and 2.
Adjustable limits:
CN207 PB level:  47.3 to 53.1 mV (–24.3 to –23.3 dB)
Adjustment Location:  MAIN board
[MAIN  BOARD]
 (Component Side)
Adjustment and Connection Location:
[AUDIO  BOARD]  
(Conductor Side)
RECORD
BAIS
TAPE SPEED
(NORMAL)
RV651
®
(HIGH)
RV652
®
RV311
®
RV411
®
PB
LEVEL
RV441 RV341
RV301
®
L
RV401
®
R
R
L
– DECK B –
– DECK A –
PB LEVEL
    
set
pin 
6
  (L-CH) of IC1501 on the MAIN board.
pin 
  (R-CH) of IC1501 on the MAIN board.
315 Hz, 50 mV (–23.8 dB)
blank tape
CS-123
pin 
2
  (GND) of CN207 on the MAIN board.
600 
attenuator
AF OSC
Page of 67