DOWNLOAD Sony HCD-SHAKEX3 / HCD-SHAKEX7 Service Manual ↓ Size: 9.05 MB | Pages: 96 in PDF or view online for FREE

Model
HCD-SHAKEX3 HCD-SHAKEX7
Pages
96
Size
9.05 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-shakex3-hcd-shakex7.pdf
Date

Sony HCD-SHAKEX3 / HCD-SHAKEX7 Service Manual ▷ View online

HCD-SHAKEX1/SHAKEX3/SHAKEX7
17
SECTION  3
TEST  MODE
[PANEL TEST MODE]
This mode is used to check the fl uorescent indicator tube, LEDs, 
keys, [VOLUME/MULTI CONTROL] knob, model, destination 
and software version.
Procedure:
1. Press [] button and [S3 TUNING ‒ .] button simultane-
ously and hold 3 seconds.
2.  All LEDs and segments in fl uorescent indicator tube are 
lighted up. All RGB LEDs are lighted up in white color.
3.  When you want to enter to the software version display mode, 
press [S2 +] button.
 
The model information appears on the fl uorescent  indicator 
tube.
 Press 
[S2 
+] button again to view the destination information.
4.  During the destination information display, press [S2 +] 
button. Each time [S2 +] button is pressed, the fl uorescent 
indicator tube shows the version of each category software 
in the following sequence: SC, MTK, OPU, UI, PF, SUB, 
SYS, CD, CMA, CMB, ST, TA, TM and return back to model 
information display.
5. When [] button is pressed while the version numbers 
are being displayed except model and destination, the 
date of the software creation appears. When [] button is 
pressed again, the display returns to the software version 
display.
6. Press 
[S1 
‒] button, the key check mode is activated.
7.  In the key check mode, the fl uorescent indicator tube displays 
“K 0    V0”.
 
Each time a button is pressed, “K” value increases. However, 
once a button has been pressed, it is no longer taken into 
account.
 
“V” value increases in the manner of 0, 1, 2, 3 ... if [VOLUME/
MULTI CONTROL] knob is turned clockwise, or it decreases 
in the manner of 0, 9, 8, 7 ... if [VOLUME/MULTI CONTROL] 
knob is turned counterclockwise.
8.  When [ENTER] button is pressed after all LEDs and segments 
in  fl uorescent indicator tube light up, alternate segments in 
fl uorescent indicator tube and LEDs would light up, all RGB 
LEDs would light up in RED color. If you press [ENTER] 
button again, another half of alternate segments in fl uorescent 
indicator tube and LEDs would light up, all RGB LEDs would 
light up in GREEN color. Pressing [ENTER] button again 
would cause all segments in fl uorescent indicator tube and 
LEDs light up, all RGB LEDs would light up in blue color. 
Pressing [ENTER] button again would turn off all segments in 
fl uorescent indicator tube and all LEDs including RGB LEDs.
9.  To release from this mode, press the buttons in the same 
manner as step 1, or disconnect the power cord.
[USER RESET]
The user reset clears all data including preset data stored in the data 
fl ash to initial conditions exclude history mode data.
Procedure:
1. Press 
\/1
 button to turn on the system.
2.  Press [DJ OFF] button and [S4 TUNING + >] button simul-
taneously for 3 seconds.
3.  “RESET” appears on the fl uorescent indicator tube. After that, 
the fl uorescent indicator tube becomes blank for a while, and 
the system is reset.
[COLD RESET]
The cold reset clears all data including preset data stored in the 
data fl ash to initial conditions included history mode data. Execute 
this mode when returning the set to the customer.
Procedure:
1. Press 
[
\/1
] button to turn on the system.
2. Press [] button and [S4 TUNING + >] button simultane-
ously for 3 seconds.
3.  “COLD RESET” appears on the fl uorescent indicator tube. 
After that, the fl uorescent indicator tube will display “SONY 
DEMO”. The set will automatically Power ON and Power 
OFF again, and the system is reset.
[DISC TRAY LOCK MODE]
This mode let you lock the disc tray. When this mode is activated, 
the disc tray will not open when [Z] button is pressed. The message 
“LOCKED” will be displayed on the fl uorescent indicator tube. 
This mode only applied when there is disc on the tray.
Procedure:
1. Press 
[
\/1
] button to turn on the system.
2.  Select DVD/CD function.
3.  Press [DJ OFF] button and [ISOLATOR] button simultaneously 
and hold down until “LOCKED” or “UNLOCKED” displayed 
on the fl uorescent indicator tube (around 5 seconds).
[Bluetooth PAIRING HISTORY CLEAR]
It can clear the Bluetooth pairing history.
Procedure:
1. Press 
the 
[
\/1
] button to turn the power on.
2.  Press the [BLUETOOTH] button to turn the Bluetooth func-
tion.
3.  Press [DJ OFF] button and [‒] button simultaneously for 3 
seconds.
4.  The message “BT HISTORY” → “CLEAR” is displayed 
on the fluorescent indicator tube, and the pairing history of 
Bluetooth is cleared.
Ver. 1.1
HCD-SHAKEX1/SHAKEX3/SHAKEX7
18
Display on fl uorescent indicator tube
Description
P
C
O
U
N
T
No of time protector happen (0 ~ 99)
P
T
Refer to protect type description
1
*h
*h
*h
*h
*h.
*m
*m
Single Power On Time until protector happened
(0~99999 hours, 0~99Min)
2
*h
*h
*h
*h
*h.
*m
*m
Total Power On Time [ no consider protector happen ]
(0~99999 hours, 0~99Min)
F
Input Function during protector happened
V
O
L
Volume setting (MIN / 1 - 50 / MAX)
B
A
S
S
MEGA BASS setting (OFF / ON)
[HISTORY MODE]
This mode is used to check important data stored in the system 
when PROTECTOR happen.
Procedure:
1.  During demo mode, press [] button and [S2 +] button for 
5 seconds to mode into history mode.
2.  Press the [S4 TUNING + >] button or [S3 TUNING ‒ .] 
button to check history data stored.
To release from History Mode.
To release from this mode, press [
\/1
] button.
Protect Type Description:
Error Code 
Description
01
The over current condition to MOSFET occurs 
by defect of MOSFET or defect of PS output 
line.
or
Unusual heat up of MOSFET by improper 
assembly of heat sink, destruction of MOSFET 
etc.
02
Defect of thermistor IC or charging circuit used 
by SPM (Sound Pressure Management) system.
03
Defect of power supply circuit to AMP. There 
is possibility of unusual power supply of any of 
the AMP IC or Pre-amplifi er.
04
DC appears in SP terminal by defect of AMP 
IC and MOSFET
06
Defect of DC FAN and DC FAN driver circuit
If speaker does not have output even if the set status is not in 
PROTECT mode, the following defect might be possible:
Defects
Possible cause
RESET defect
Reset signal status from micom is not ‘H’.
Ver. 1.1
HCD-SHAKEX1/SHAKEX3/SHAKEX7
19
[DVD COLOR SYSTEM MODE]
  This mode let you change the color system of the video output 
from PAL to NTSC or vice-versa.
Procedure:
1.  Press the [\/1] button to turn on the system.
2.  Press [FUNCTION +] or [FUNCTION ‒] at remote com-
mander to select DVD/CD function.
3. Press the [DJ OFF] button and [FOOTBALL] button 
simultaneously and hold for 3 seconds.
4.  The message “COLOR PAL” or “COLOR NTSC” appears on 
the fl uorescent indicator tube.
•  To release from DVD Color System Mode
1.  Once the color system has been selected, the mode is fi xed 
there after. If you wish to change the mode again, perform the 
above item 2 again.
[DVD SERVICE MODE]
  This mode let you make diagnosis and adjustment easily by 
using the remote commander and the TV. The instructions, 
diagnostic results, etc. are given on the on-screen display.
•  TEST DISC LIST
 
Be sure to use the DVD disc that matches the signal standards 
of your region.
 
•  CD
 
 
 
YEDS-18 
(Part No.: 3-702-101-01)
 
 
 
PATD-012 
(Part No.: 4-225-203-01)
 
 
 
HLX-A1 
(Part No.: J-2501-307-A)
 
•  DVD SL (Single Layer)
 
 
NTSC :  HLX-503  (Part No.: J-6090-069-A)
 
 
 
  HLX-504  (Part No.: J-6090-088-A)
 
 
 
  HLX-513  (Part No.: J-2501-305-A)
 
 
PAL : HLX-506  (Part No.: J-6090-077-A)
 
•  DVD DL (Double Layer)
 
 
NTSC :  HLX-501  (Part No.: J-6090-071-A)
 
 
 
  HLX-505  (Part No.: J-6090-089-A)
 
 
 
  HLX-514  (Part No.: J-2501-306-A)
 
 
PAL : HLX-507  (Part No.: J-6090-078-A)
•  Procedure to enter to DVD Service Mode:
1.  Press the [\/1] button to turn on the system.
2.  Press [FUNCTION +] or [FUNCTION ‒] at remote com-
mander to select DVD/CD function.
3.  Press the [SPEAKER LIGHT] button and [ENTER] button 
simultaneously and hold 3 seconds.
4.  The message “SERVICE IN” appears on the fl uorescent 
indicator tube.
 
The display of the “Model Name” of the “Remocon Diagnosis 
Menu” change with the model and the destination appears on 
screen display. Refer to below on the model name.
 
SHAKE-X1D : TETSUJIN
 
SHAKE-X3D : RAIJIN
 
SHAKE-X7D : RYUJIN
 
*1: Changes depending on destination
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name : SHAKE-X1D_ XX *1 or SHAKE-X3D_ XX 
*
1 or
: SHAKE-X7D_ XX 
*
1
IF-con
Syscon
: Ver.  XX.XX (XXXX)
: Ver.  X.XXX
Ver. 1.1
5.  To execute each function, press its number by using numeric 
button on the remote commander.
6.  To release from this mode, press the [\/1] button to turn off 
the system.
•  Execute IOP Measurement
 
In order to execute IOP measurement, the following standard 
procedures must be followed.
1.  From the Top Menu of Remocon Diagnosis Menu, select 
“2. Drive Manual Operation” by pressing the [2] button on 
the remote commander. The following screen appears on the 
onscreen display.
2.  Select “3. Manual Adjustment” by pressing the [3] button on 
the remote commander. The following screen appears on the 
on-screen display.
3.  Select “6. Iop:” by pressing the [6] button on the remote 
commander.
4.  Wait until a hexadecimal number appears in the on-screen 
display as below:
5. Convert data from hexadecimal to decimal by using 
conversion table.
6. Please 
fi nd the label on the rear of the BU (Base Unit).
 
The default IOP value is written in the label.
7.  Subtract between these two values.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time Adjust
0. Return to Top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
 
o Change Value
RETURN  Return to previous menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. ED
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
 
o Change Value
RETURN  Return to previous menu
HCD-SHAKEX1/SHAKEX3/SHAKEX7
20
•  Error Code
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
•  Parameter of error code
 
This is the detail of error code.
•  Time of error code
 
This is the laser time when an error occurred.
To clear the Laser Hours
Press the [  DISPLAY] button and then press the [CLEAR] 
button. The data for both CD and DVD data are reset.
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
Emg. History Check
1.  01  05  04  04
Laser Hours
CD
0h
0min
DVD
0h
0min
00  92  46  00
00  00  00  00
00  00  23  45
2.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
Next   Next Page
Prev  Prev Page
O  Return to Top Menu
8.  If the remainder is smaller than 93 (decimal), then it is OK.
 
However if the value is higher than 93, then the BU is defective 
and need to be change.
9.  Press the [RETURN] button on the remote commander to 
return to previous menu.
10.  Press the [0] button on the remote commander to return to the 
Top Menu of Remocon Diagnosis Menu.
11.  Press the [\/1] button to turn off the system.
•  Check Emergency History
 
To check the emergency history, please follow the following 
procedure.
1.  From the Top Menu of Remocon Diagnosis Menu, select 
“3. Emergency History” by pressing the [3] button on the 
remote commander. The following screen appears on the on-
screen display.
Emg. History Check
1.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
2.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
Next   Next Page
Prev   Prev Page
O  Return to Top Menu
 
(Displayed values in the above fi gure are example)
2.  You can check the total time when the laser is turned on 
during playback of DVD and CD from the above menu. The 
maximum time, which can be displayed are 999h 59min.
3.  You can check the error code of latest 10 emergency history 
from the above menu. To view the previous or next page of 
emergency history, press the [.] button or [>] button 
on the remote commander. The error code consists of “Error 
Code”, “Parameter of error code” and “Time of error code”.
Ver. 1.1
Page of 96
Display