Sony HCD-SHAKEX3 / HCD-SHAKEX7 Service Manual ▷ View online
HCD-SHAKEX1/SHAKEX3/SHAKEX7
17
SECTION 3
TEST MODE
[PANEL TEST MODE]
This mode is used to check the fl uorescent indicator tube, LEDs,
keys, [VOLUME/MULTI CONTROL] knob, model, destination
and software version.
Procedure:
1. Press [] button and [S3 TUNING ‒ .] button simultane-
This mode is used to check the fl uorescent indicator tube, LEDs,
keys, [VOLUME/MULTI CONTROL] knob, model, destination
and software version.
Procedure:
1. Press [] button and [S3 TUNING ‒ .] button simultane-
ously and hold 3 seconds.
2. All LEDs and segments in fl uorescent indicator tube are
lighted up. All RGB LEDs are lighted up in white color.
3. When you want to enter to the software version display mode,
press [S2 +] button.
The model information appears on the fl uorescent indicator
tube.
tube.
Press
[S2
+] button again to view the destination information.
4. During the destination information display, press [S2 +]
button. Each time [S2 +] button is pressed, the fl uorescent
indicator tube shows the version of each category software
in the following sequence: SC, MTK, OPU, UI, PF, SUB,
SYS, CD, CMA, CMB, ST, TA, TM and return back to model
information display.
indicator tube shows the version of each category software
in the following sequence: SC, MTK, OPU, UI, PF, SUB,
SYS, CD, CMA, CMB, ST, TA, TM and return back to model
information display.
5. When [] button is pressed while the version numbers
are being displayed except model and destination, the
date of the software creation appears. When [] button is
pressed again, the display returns to the software version
display.
date of the software creation appears. When [] button is
pressed again, the display returns to the software version
display.
6. Press
[S1
‒] button, the key check mode is activated.
7. In the key check mode, the fl uorescent indicator tube displays
“K 0 V0”.
Each time a button is pressed, “K” value increases. However,
once a button has been pressed, it is no longer taken into
account.
once a button has been pressed, it is no longer taken into
account.
“V” value increases in the manner of 0, 1, 2, 3 ... if [VOLUME/
MULTI CONTROL] knob is turned clockwise, or it decreases
in the manner of 0, 9, 8, 7 ... if [VOLUME/MULTI CONTROL]
knob is turned counterclockwise.
MULTI CONTROL] knob is turned clockwise, or it decreases
in the manner of 0, 9, 8, 7 ... if [VOLUME/MULTI CONTROL]
knob is turned counterclockwise.
8. When [ENTER] button is pressed after all LEDs and segments
in fl uorescent indicator tube light up, alternate segments in
fl uorescent indicator tube and LEDs would light up, all RGB
LEDs would light up in RED color. If you press [ENTER]
button again, another half of alternate segments in fl uorescent
indicator tube and LEDs would light up, all RGB LEDs would
light up in GREEN color. Pressing [ENTER] button again
would cause all segments in fl uorescent indicator tube and
LEDs light up, all RGB LEDs would light up in blue color.
Pressing [ENTER] button again would turn off all segments in
fl uorescent indicator tube and all LEDs including RGB LEDs.
fl uorescent indicator tube and LEDs would light up, all RGB
LEDs would light up in RED color. If you press [ENTER]
button again, another half of alternate segments in fl uorescent
indicator tube and LEDs would light up, all RGB LEDs would
light up in GREEN color. Pressing [ENTER] button again
would cause all segments in fl uorescent indicator tube and
LEDs light up, all RGB LEDs would light up in blue color.
Pressing [ENTER] button again would turn off all segments in
fl uorescent indicator tube and all LEDs including RGB LEDs.
9. To release from this mode, press the buttons in the same
manner as step 1, or disconnect the power cord.
[USER RESET]
The user reset clears all data including preset data stored in the data
fl ash to initial conditions exclude history mode data.
Procedure:
1. Press
The user reset clears all data including preset data stored in the data
fl ash to initial conditions exclude history mode data.
Procedure:
1. Press
\/1
button to turn on the system.
2. Press [DJ OFF] button and [S4 TUNING + >] button simul-
taneously for 3 seconds.
3. “RESET” appears on the fl uorescent indicator tube. After that,
the fl uorescent indicator tube becomes blank for a while, and
the system is reset.
the system is reset.
[COLD RESET]
The cold reset clears all data including preset data stored in the
data fl ash to initial conditions included history mode data. Execute
this mode when returning the set to the customer.
Procedure:
1. Press
The cold reset clears all data including preset data stored in the
data fl ash to initial conditions included history mode data. Execute
this mode when returning the set to the customer.
Procedure:
1. Press
[
\/1
] button to turn on the system.
2. Press [] button and [S4 TUNING + >] button simultane-
ously for 3 seconds.
3. “COLD RESET” appears on the fl uorescent indicator tube.
After that, the fl uorescent indicator tube will display “SONY
DEMO”. The set will automatically Power ON and Power
OFF again, and the system is reset.
DEMO”. The set will automatically Power ON and Power
OFF again, and the system is reset.
[DISC TRAY LOCK MODE]
This mode let you lock the disc tray. When this mode is activated,
the disc tray will not open when [Z] button is pressed. The message
“LOCKED” will be displayed on the fl uorescent indicator tube.
This mode only applied when there is disc on the tray.
Procedure:
1. Press
This mode let you lock the disc tray. When this mode is activated,
the disc tray will not open when [Z] button is pressed. The message
“LOCKED” will be displayed on the fl uorescent indicator tube.
This mode only applied when there is disc on the tray.
Procedure:
1. Press
[
\/1
] button to turn on the system.
2. Select DVD/CD function.
3. Press [DJ OFF] button and [ISOLATOR] button simultaneously
3. Press [DJ OFF] button and [ISOLATOR] button simultaneously
and hold down until “LOCKED” or “UNLOCKED” displayed
on the fl uorescent indicator tube (around 5 seconds).
on the fl uorescent indicator tube (around 5 seconds).
[Bluetooth PAIRING HISTORY CLEAR]
It can clear the Bluetooth pairing history.
Procedure:
1. Press
It can clear the Bluetooth pairing history.
Procedure:
1. Press
the
[
\/1
] button to turn the power on.
2. Press the [BLUETOOTH] button to turn the Bluetooth func-
tion.
3. Press [DJ OFF] button and [‒] button simultaneously for 3
seconds.
4. The message “BT HISTORY” → “CLEAR” is displayed
on the fluorescent indicator tube, and the pairing history of
Bluetooth is cleared.
Bluetooth is cleared.
Ver. 1.1
HCD-SHAKEX1/SHAKEX3/SHAKEX7
18
Display on fl uorescent indicator tube
Description
P
C
O
U
N
T
※
※
No of time protector happen (0 ~ 99)
P
T
※
※
※
※
Refer to protect type description
1
*h
*h
*h
*h
*h.
*m
*m
Single Power On Time until protector happened
(0~99999 hours, 0~99Min)
(0~99999 hours, 0~99Min)
2
*h
*h
*h
*h
*h.
*m
*m
Total Power On Time [ no consider protector happen ]
(0~99999 hours, 0~99Min)
(0~99999 hours, 0~99Min)
F
※
※
※
※
※
※
Input Function during protector happened
V
O
L
※
※
※
Volume setting (MIN / 1 - 50 / MAX)
B
A
S
S
※
※
※
MEGA BASS setting (OFF / ON)
[HISTORY MODE]
This mode is used to check important data stored in the system
when PROTECTOR happen.
Procedure:
1. During demo mode, press [] button and [S2 +] button for
This mode is used to check important data stored in the system
when PROTECTOR happen.
Procedure:
1. During demo mode, press [] button and [S2 +] button for
5 seconds to mode into history mode.
2. Press the [S4 TUNING + >] button or [S3 TUNING ‒ .]
button to check history data stored.
To release from History Mode.
To release from this mode, press [
To release from this mode, press [
\/1
] button.
Protect Type Description:
Error Code
Description
01
The over current condition to MOSFET occurs
by defect of MOSFET or defect of PS output
line.
or
Unusual heat up of MOSFET by improper
assembly of heat sink, destruction of MOSFET
etc.
by defect of MOSFET or defect of PS output
line.
or
Unusual heat up of MOSFET by improper
assembly of heat sink, destruction of MOSFET
etc.
02
Defect of thermistor IC or charging circuit used
by SPM (Sound Pressure Management) system.
by SPM (Sound Pressure Management) system.
03
Defect of power supply circuit to AMP. There
is possibility of unusual power supply of any of
the AMP IC or Pre-amplifi er.
is possibility of unusual power supply of any of
the AMP IC or Pre-amplifi er.
04
DC appears in SP terminal by defect of AMP
IC and MOSFET
IC and MOSFET
06
Defect of DC FAN and DC FAN driver circuit
If speaker does not have output even if the set status is not in
PROTECT mode, the following defect might be possible:
PROTECT mode, the following defect might be possible:
Defects
Possible cause
RESET defect
Reset signal status from micom is not ‘H’.
Ver. 1.1
HCD-SHAKEX1/SHAKEX3/SHAKEX7
19
[DVD COLOR SYSTEM MODE]
• This mode let you change the color system of the video output
• This mode let you change the color system of the video output
from PAL to NTSC or vice-versa.
Procedure:
1. Press the [\/1] button to turn on the system.
2. Press [FUNCTION +] or [FUNCTION ‒] at remote com-
1. Press the [\/1] button to turn on the system.
2. Press [FUNCTION +] or [FUNCTION ‒] at remote com-
mander to select DVD/CD function.
3. Press the [DJ OFF] button and [FOOTBALL] button
simultaneously and hold for 3 seconds.
4. The message “COLOR PAL” or “COLOR NTSC” appears on
the fl uorescent indicator tube.
• To release from DVD Color System Mode
1. Once the color system has been selected, the mode is fi xed
1. Once the color system has been selected, the mode is fi xed
there after. If you wish to change the mode again, perform the
above item 2 again.
above item 2 again.
[DVD SERVICE MODE]
• This mode let you make diagnosis and adjustment easily by
• This mode let you make diagnosis and adjustment easily by
using the remote commander and the TV. The instructions,
diagnostic results, etc. are given on the on-screen display.
diagnostic results, etc. are given on the on-screen display.
• TEST DISC LIST
Be sure to use the DVD disc that matches the signal standards
of your region.
of your region.
• CD
YEDS-18
(Part No.: 3-702-101-01)
PATD-012
(Part No.: 4-225-203-01)
HLX-A1
(Part No.: J-2501-307-A)
• DVD SL (Single Layer)
NTSC : HLX-503 (Part No.: J-6090-069-A)
HLX-504 (Part No.: J-6090-088-A)
HLX-513 (Part No.: J-2501-305-A)
PAL : HLX-506 (Part No.: J-6090-077-A)
• DVD DL (Double Layer)
NTSC : HLX-501 (Part No.: J-6090-071-A)
HLX-505 (Part No.: J-6090-089-A)
HLX-514 (Part No.: J-2501-306-A)
PAL : HLX-507 (Part No.: J-6090-078-A)
• Procedure to enter to DVD Service Mode:
1. Press the [\/1] button to turn on the system.
2. Press [FUNCTION +] or [FUNCTION ‒] at remote com-
1. Press the [\/1] button to turn on the system.
2. Press [FUNCTION +] or [FUNCTION ‒] at remote com-
mander to select DVD/CD function.
3. Press the [SPEAKER LIGHT] button and [ENTER] button
simultaneously and hold 3 seconds.
4. The message “SERVICE IN” appears on the fl uorescent
indicator tube.
The display of the “Model Name” of the “Remocon Diagnosis
Menu” change with the model and the destination appears on
screen display. Refer to below on the model name.
Menu” change with the model and the destination appears on
screen display. Refer to below on the model name.
SHAKE-X1D : TETSUJIN
SHAKE-X3D : RAIJIN
SHAKE-X7D : RYUJIN
*1: Changes depending on destination
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name : SHAKE-X1D_ XX *1 or SHAKE-X3D_ XX
*
1 or
: SHAKE-X7D_ XX
*
1
IF-con
Syscon
Syscon
: Ver. XX.XX (XXXX)
: Ver. X.XXX
: Ver. X.XXX
Ver. 1.1
5. To execute each function, press its number by using numeric
button on the remote commander.
6. To release from this mode, press the [\/1] button to turn off
the system.
• Execute IOP Measurement
In order to execute IOP measurement, the following standard
procedures must be followed.
procedures must be followed.
1. From the Top Menu of Remocon Diagnosis Menu, select
“2. Drive Manual Operation” by pressing the [2] button on
the remote commander. The following screen appears on the
onscreen display.
the remote commander. The following screen appears on the
onscreen display.
2. Select “3. Manual Adjustment” by pressing the [3] button on
the remote commander. The following screen appears on the
on-screen display.
on-screen display.
3. Select “6. Iop:” by pressing the [6] button on the remote
commander.
4. Wait until a hexadecimal number appears in the on-screen
display as below:
5. Convert data from hexadecimal to decimal by using
conversion table.
6. Please
fi nd the label on the rear of the BU (Base Unit).
The default IOP value is written in the label.
7. Subtract between these two values.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time Adjust
0. Return to Top Menu
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time Adjust
0. Return to Top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
o Change Value
RETURN Return to previous menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. ED
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. ED
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
o Change Value
RETURN Return to previous menu
HCD-SHAKEX1/SHAKEX3/SHAKEX7
20
• Error Code
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
• Parameter of error code
This is the detail of error code.
• Time of error code
This is the laser time when an error occurred.
To clear the Laser Hours
Press the [ DISPLAY] button and then press the [CLEAR]
button. The data for both CD and DVD data are reset.
Press the [ DISPLAY] button and then press the [CLEAR]
button. The data for both CD and DVD data are reset.
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
Emg. History Check
1. 01 05 04 04
Laser Hours
CD
0h
0min
DVD
0h
0min
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
Next Next Page
Prev Prev Page
O Return to Top Menu
8. If the remainder is smaller than 93 (decimal), then it is OK.
However if the value is higher than 93, then the BU is defective
and need to be change.
and need to be change.
9. Press the [RETURN] button on the remote commander to
return to previous menu.
10. Press the [0] button on the remote commander to return to the
Top Menu of Remocon Diagnosis Menu.
11. Press the [\/1] button to turn off the system.
• Check Emergency History
To check the emergency history, please follow the following
procedure.
procedure.
1. From the Top Menu of Remocon Diagnosis Menu, select
“3. Emergency History” by pressing the [3] button on the
remote commander. The following screen appears on the on-
screen display.
remote commander. The following screen appears on the on-
screen display.
Emg. History Check
1. 01 05 04 04
Laser Hours
CD
999h
59min
DVD
999h
59min
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
Next Next Page
Prev Prev Page
O Return to Top Menu
(Displayed values in the above fi gure are example)
2. You can check the total time when the laser is turned on
during playback of DVD and CD from the above menu. The
maximum time, which can be displayed are 999h 59min.
maximum time, which can be displayed are 999h 59min.
3. You can check the error code of latest 10 emergency history
from the above menu. To view the previous or next page of
emergency history, press the [.] button or [>] button
on the remote commander. The error code consists of “Error
Code”, “Parameter of error code” and “Time of error code”.
emergency history, press the [.] button or [>] button
on the remote commander. The error code consists of “Error
Code”, “Parameter of error code” and “Time of error code”.
Ver. 1.1
Click on the first or last page to see other HCD-SHAKEX3 / HCD-SHAKEX7 service manuals if exist.