– 29 –
7. In the aging mode, the aging is executed in a sequence given
in “2-2.  Operation during Aging Mode”.
The aging continues unless an alarm occurred.
8. To exit from the aging mode, press POWER button to turn
the set OFF.
2-2.  Operation during Aging Mode
In the aging mode, the program is executed in the following se-
quence.
1. A tape on FWD side is played for one minute.
2. PAUSE STOP is made.
3. Recording is made for 3 minutes. (For the deck not having
the record function, the play is executed.  In this case,
·
LED does not light up.)
4. FF is executed up to the end of tape.
5. A tape is reversed, and the tape on REV side is played for
one minute.
6. PAUSE STOP is made.
7. Recording is made for 3 minutes.  (For the deck not having
the record function, the play is executed.  In this case,
ª
LED does not light up.)
8. FF is executed up to the end of tape.
9. Steps 1 through 8 are executed for the other deck.
10. Steps 1 through 9 are repeated unless an alarm occurred.
2-3.  Deck Selection Sequence
During the aging mode, decks are selected in the following se-
quence:
Deck A (FWD) 
 Deck A (REV)
Deck B (REV) 
 Deck B (FWD)
[Aging Mode]
This mode can be used for operation check of CD section and tape
deck section.
If an error occurred:
The aging operation stops.
If no error occurs:
The aging operation continues repeatedly.
1. Aging Mode in CD Section
1-1.  Operating Method of Aging Mode
1. Set discs in DISC1 and DISC2 trays.
2. Select the function “CD”.
3. Press three buttons SPECTRUM ANALYZER ,
ENTER/NEXT , and KARAOKE PON/MPX  simulta-
neously.
4. The aging mode is activated, if a roulette mark on the fluo-
rescent indicator tube is blinking.
5. In the aging mode, the aging is executed in a sequence given
in “1-2. Operation during Aging Mode”.
The aging continues unless an alarm occurred.
6. To exit from the aging mode, press POWER button to turn
the set OFF.
If a button other than buttons In CD section is pressed during
aging, the aging in the CD section is finished.
To execute aging to the tape deck section successively, press
·
button in the deck A.
“AGING” is displayed on the fluorescent indicator tube.  (For the
aging in tape deck, see “2. Aging Mode in Tape Deck Section”.
1-2.  Operation during aging Mode
In the aging mode, the program is executed in the following se-
quence.
1. The disc table is ejected.
2. The disc tray turns to select a disc. (For a disc selection
sequence, see Section 1-3.)
3. TOC of disc is read.
4. The pickup accesses to the last track.
5. A disc is ejected.
6. Steps 2 through 5 are repeated.
1-3.  Disc Selection Sequence
During the aging mode, discs are selected in the following se-
quence:
Disc 1 
 Disc 2
 
Disc 2 
 Disc 1
2. Aging Mode in Tape Deck Section
2-1.  Operating Method of Aging Mode
1. Load a commercially available 10-minute tape into the decks
A and B respectively.
(If a 10-minute tape is not available, another tape may be
used but a cycle time will be longer.)
2. Select the function “TAPE”.
3. Rewind tapes in advance by pressing
0 button respec-
tively on decks A and B.
4. Press three buttons SPECTRUM  ANALYZER ,
ENTER/NEXT , and KARAOKE PON/MPX  simulta-
neously.
5. Press
· button on deck A.  (This button triggers the ag-
ing mode.)
6. The aging mode is activated if “AGING A” is displayed on
the fluorescent indicator tube.
– 30 –
SECTION  4
MECHANICAL  ADJUSTMENTS
SECTION  5
ELECTRICAL  ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab:
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power  sup-
ply voltage unless otherwise noted.
• Torque  Measurement
Mode
Torque Meter
Meter Reading
Forward
CQ-102C
36 to 61 g•cm
(0.50 – 0.84 oz•inch)
Forward
CQ-102C
2 to 6 g•cm
Back Tension
(0.026 – 0.082 oz•inch)
Reverse
CQ-102RC
36 to 61 g•cm
(0.50 – 0.84 oz•inch)
Reverse
CQ-102RC
2 to 6 g•cm
Back Tension
(0.026 – 0.082 oz•inch)
FF, REW
CQ-201B
61 to 143 g•cm
(0.85 – 1.98 oz•inch)
• Tape Tension  Measurement
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 100 g (3.53 oz)
Reverse
CQ-403R
more than 100 g (3.53 oz)
DECK  SECTION
0 dB=0.775 V
1. Demagnetize the record/playback head with a head demagne-
tizer.  (Do not bring the head demagnetizer close to the erase
head.)
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjustment
should be completed before performing recording circuit ad-
justment.)
6. The adjustments should be performed for both L-CH and R-ch.
7. Switches and controls should be set as follows unless otherwise
specified.
8. Set to test mode.  (Press key switch same time
SPECTRUM ANALYZER   ENTER/NEXT and
EFFECT ON/OFF button.)
Test Tape
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
P-4-L300
315 Hz, 0 dB
Level Adjustment
Record/Playback Head Azimuth Adjustment
DECK A
DECK B
Note:  Perform this adjustments for both decks
Procedure:
1. Mode:  Playback (FWD)
set
main board
CN207
Pin 
1
 (L-CH)
Pin 
3
 (R-CH)
main board
CN207
Pin 
2
 
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
– 31 –
2. Turn the adjustment screw and check output peaks.  If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback (FWD)
4. Repeat steps 1 to 3 in playback (REV) mode.
5. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location:  Record/Playback Head (Deck A and B)
and main board.
reverse
forward
Tape Speed Adjustment
DECK  A
Note: Start the Tape Speed adjustment as below after setting to the
test mode.
In the test mode, the tape speed is high during pressing the
 HIGH SPEED DUBBING button.
Procedure:
1. Turn the power switch on.
2. Press the SPECTRUM ANALYZER button,
ENTER/NEXT button and EFFECT ON/OFF button simul-
taneously.
To exit from the test mode, press the POWER button.
Mode:  Playback (FWD)
Screw
position
L-CH
peak
within
1dB
output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
main
board
CN207
set
test tape
P-4-A100
(10 kHz, –10 dB)
pin 
3
oscilloscope
 L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
pin 
2
pin 
1
L
R
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
main board
CN207 (Pin 
1
 : L-CH)
     (Pin 
3
 :R-CH)
frequency counter
1. Insert the WS-48B into the deck A and the blank tape into the
deck B.
2. Press the REC button and
· button on the deck B.  Then
the deck B is at recording mode.
3. Set the deck A to playback mode.
4. Keep pressing the HIGH SPEED DUBBING button in play-
back mode.
Then at HIGH speed mode.
5. Adjust RV652 on the AUDIO board do that frequency counter
reads 6,000 ± 60 Hz.
6. Take off the HIGH SPEED DUBBING button.
Then at NORMAL speed mode.
7. Adjust RV651 on the AUDIO  board so that frequency counter
reads 3,000      Hz.
8. Frequency difference between deck A and deck B the beginning
of the tape should be within ± 1.5%.
Adjustment Location:  AUDIO board
+30
–10
Playback level Adjustment
DECK A
DECK B
Procedure:
Mode:  Playback (FWD)
Deck A is RV311 (L-CH) and RV411 (R-CH), Deck B is RV301 (L-
CH) and RV401 (R-CH) so that adjustment within adjustment level
as follows.
Adjustment Level:
CN207 PB level:  301.5 to 338.3 mV (–8.2 to  –7.2 dB) level
difference between the channels:  within ±0.5 dB
Adjustment Location:  AUDIO and main boards
+
set
test tape
P-4-L300
(315 Hz, 0 dB)
main board
CN207 (Pin 
1
: L-CH)
(Pin 
3
: R-CH)
level meter
– 32 –
Record bias Current Adjustment
DECK B
Procedure:
1. Mode:  Record
2. Mode:  Playback
+
set
recorded
portion
CN207 (Pin 
1
: L-CH)
(Pin 
3
: R-CH)
level meter
Confirm playback the signal recorded in step 1 become adjustable
limits as follows.
If these levels do not adjustable limits, adjustment the RV341 (L-CH)
and RV441 (R-CH) on the AUDIO board to repeat steps 1 and 2.
Adjustable limits: Playback output of 315 Hz to playback output
of 10kHz:  ±0.5 dB
Adjustment Location: AUDIO and main boards
Record Level Adjustment   DECK B
Procedure:
1. Mode:  Record
Adjustment Location:  Main board
[MAIN  BOARD] (Component Side)
[AUDIO  BOARD]  (Conductor Side)
attenuator
set
Pin 
6
 (L-CH) of IC1501 on the main board.
Pin 
 (L-CH) of IC1501 on the main board.
1) 315 Hz
2) 10 kHz
50 mV (–23.8 dB)
Pin 
2
 (GND) of ICN207 on the main board.
600 
blank tape
CN-123
AF OSC
2. Mode:  Playback
Confirm playback the signal recorded in step 1 become adjustable
limits as follows.
If these levels do not adjustable limits, adjustment the RV1501 (L-
CH) and RV1551 (R-CH) on the main board to repeat steps 1 and 2.
Adjustable limits:
CN207 PB level:  47.3 to 53.1 mV (–24.3 to –23.3 dB)
set
Pin 
6
  (L-CH) of IC1501 on the main board.
Pin 
  (R-CH) of IC1501 on the main board.
315 Hz, 50 mV (–23.8 dB)
blank tape
CS-123
Pin 
2
  (GND) of CN207 on the main board.
600 
attenuator
AF OSC
RECORD
BAIS
TAPE SPEED
(NORMAL)
RV651
®
(HIGH)
RV652
®
RV311
®
RV411
®
PB
LEVEL
RV441 RV341
RV301
®
L
RV401
®
R
R
L
– DECK B –
– DECK A –
PB LEVEL
    
+
set
recorded
portion
CN207 (Pin 
1
: L-CH)
(Pin 
3
: R-CH)
level meter
RV1501
IC1501
CN205
CN207
RV1551
RECORD LEVEL
IC301
IC201
Page of 73