DOWNLOAD Sony HCD-RG295 / HCD-RG495 / HCD-RG595 / MHC-RG295 / MHC-RG495 / MHC-RG595 Service Manual ↓ Size: 10.49 MB | Pages: 86 in PDF or view online for FREE

Model
HCD-RG295 HCD-RG495 HCD-RG595 MHC-RG295 MHC-RG495 MHC-RG595
Pages
86
Size
10.49 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-rg295-hcd-rg495-hcd-rg595-mhc-rg295-mhc-rg495-.pdf
Date

Sony HCD-RG295 / HCD-RG495 / HCD-RG595 / MHC-RG295 / MHC-RG495 / MHC-RG595 Service Manual ▷ View online

HCD-RG295/RG495/RG595
13
3-10. CD  BOARD
3
CD board
2
Remove soldering from the four points.
1
flexible flat (16 core) cable
(CN301)
CD machanism deck
(back side)
3-11. DRIVER  BOARD,  SW  BOARD
3
connector
(CN703)
4
DRIVER board
6
SW board
2
wire (flat type) (5 core)
(CN702)
1
two screws
(BTTP (M2.6))
5
screw
(BTTP (M2.6))
CD machanism deck
(back side)
HCD-RG295/RG495/RG595
14
3-12. OPTICAL  PICK-UP  BLOCK (KSM-213DCP)
3-13. SENSOR  BOARD
4
two coil springs 
(insulator)
7
two coil springs 
(insulator)
5
two insulators 
8
two insulators 
6
two floating screws
(PTPWH M2.6)
2
holder (213) assy
0
Remove the four solders of motor.
qa
flexible flat cable (16 core)
(CN301)
qs
CD board
qd
optical pick-up block
(KSM-213DCP)
1
floating screw 
(PTPWH M2.6)
3
two floating screws
(PTPWH M2.6)
9
2
tray
3
belt (table)
5
pulley (table)
8
screw
(BTTP (M2.6))
0
SENSOR board
7
gear (geneva)
9
connector
(CN731)
1
floating screw 
(PTPWH M2.6)
6
floating screw 
(PTPWH M2.6)
4
floating screw 
(PTPWH M2.6)
HCD-RG295/RG495/RG595
15
3-14. MOTOR (TB)  BOARD
3-15. MOTOR (LD)  BOARD
6
Remove the two solderings of motor.
8
MOTOR (TB) board
7
table motor assy (M741)
5
two screws
(BTTP (M2.6))
4
3
wire (flat type) (5 core) (CN742)
1
stopper
2
stopper
3
Remove the two solderings of motor.
5
MOTOR (LD) board
1
belt (loading)
4
loading motor assy (M751)
2
two screws
(BTTP (M2.6))
16
HCD-RG295/RG495/RG595
SECTION  4
TEST  MODE
COLD  RESET
The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning the
set to the customer.
Procedure:
1. Press three buttons of
x
u
  and [DISC 1] simultaneously.
2. The message “COLD RESET” is displayed on the fluorescent
indicator tube momentarily, then becomes standby states.
TUNING  STEP  CHANGE-OVER
(Except RG295: AEP and UK/RG495: AEP and Saudi
Arabia/RG595: AEP, UK and Saudi Arabia models)
A step of AM tuning interval can be changed over between 9 kHz
and 10 kHz.
Procedure:
1. Press the
I/1
button to turn the power on.
2. Press the [TUNER/BAND] button to select “AM”.
3. Press the
I/1
button to turn the power off.
4. Press two buttons of [TUNING --] and
I/1
 
 simultaneously.
5. The message “AM 9K STEP” or “AM 10K STEP” is displayed
on the fluorescent indicator tube, and thus the tuning interval
is changed over.
CD  SHIP (LOCK)  MODE
This mode moves the optical pick-up to the position durable to
vibration. Use this mode when returning the set to the customer
after repair.
Procedure:
1. Press the
I/1
button to turn the power on.
2. Press the [CD] button to select “CD”.
3. Press two buttons of  
u
 and [POWER] simultaneously.
4. The message “LOCK” is displayed on the fluorescent indicator
tube, and the CD ship mode is set.
CD  SHIP (LOCK)  MODE  &  COLD  RESET
This mode is used to perform CD ship (lock) mode and cold reset
simultaneously.
Procedure:
1. Press the
I/1
button to turn the power on.
2. Press the [CD] button to select “CD”.
3. Press three buttons of
x
, [CD] and 
 Z
  simultaneously.
4. The message “COLD RESET” is displayed on the fluorescent
indicator tube momentarily, then becomes standby states.
ANTITHEFT  LOCK  MODE
This mode is used to unable to take sample disc out of disc table in
the shop.
Procedure:
1. Press the
I/1
button to turn the power on.
2. Press the [CD] button to select “CD”.
3. Press two buttons of
x
and 
 Z
  for 5 seconds.
4. The message “LOCKED” is displayed on the fluorescent
indicator tube and the disc table is locked. (Even if pressing
the
Z
button, the message “LOCKED” is displayed on the
fluorescent indicator tube and the disc table is locked)
5. To release this mode, press two buttons of
x
and
Z
for 5
seconds.
6. The message “UNLOCKED” is displayed on the fluorescent
indicator tube and the disc table is unlocked.
AMP  TEST  MODE
This mode is used to display the parameter of amplifier IC and
display the VACS status.
Procedure:
1. Press the
I/1
button to turn the power on.
2. Press three buttons of
x
,  
u
  and 
 Z
  simultaneously.
3. When the AMP test mode is activated, the message “AMP
TEST IN” is displayed on the fluorescent indicator tube
momentarily, then amplifier adjustment mode is displayed on
the fluorescent indicator tube.
4. Press the [REC PAUSE/START] button to changed over between
VACS status display mode and the amplifier IC parameter
display mode.
5. In this mode, press the [GROOVE]  button to changed over
DBFB on/off, and “DBFB ON” or “DBFB OFF” is displayed
on the fluorescent indicator tube.
6. In this mode, press the [SURROUND] button to changed over
surround on/off, and “SUB ON” or “SUB OFF” is displayed
on the fluorescent indicator tube.
− Except HCD-RG595: E and Saudi Arabia models −
7. In this mode, press the [EQ BAND] button to enter the equalizer
adjustment mode.
In the equalizer adjustment mode, press the [EQ BAND] button
to change over the adjustment band as LOW/MID/HIGH. And
turn the multi jog knob to adjust the equalizer level of each
bands.
− HCD-RG595: E and Saudi Arabia models −
7. In this mode, press the [BASS], [VOCAL] or [GUITER] buttons
to enter the parametric equalizer adjustment mode.
In the parametric equalizer adjustment mode, press the [BASS],
[VOCAL] and [GUITER] buttons to change over the adjustment
band. And press the  
 and  
 buttons to adjust the equalizer
frequency of each bands, or press the [+] and [--] buttons to
adjust the equalizer level of each bands.
8. To release the amplifier IC parameter display mode or equalizer
adjustment mode, press the
I/1
button to the power off.
MC  TEST  MODE
This mode is used to check operations of microprocessor.
Procedure:
1. Press the
I/1
button to turn the power on.
2. Press three buttons of
x
,  
u
  and [DISC 3] simultaneously.
3. When the MC test mode is activated, VACS level is displayed
on the fluorescent indicator tube momentarily.
4. Turn the multi jog knob clockwise, the message “ALL EQ
MAX” is displayed on the fluorescent indicator tube
momentarily and turn the multi jog knob counter-
clockwise, the message “ALL EQ MIN” is displayed on
the fluorescent indicator tube momentarily.
5. Press the [ENTER] button, the message “ALL EQ FLAT” is
displayed on the fluorescent indicator tube momentarily.
6. Turn the [VOLUME] knob clockwise, the message “VOLUME
MAX” is displayed on the fluorescent indicator tube
momentarily and turn the [VOLUME] knob counterclockwise,
the message “VOLUME MIN” is displayed on the fluorescent
indicator tube momentarily.
7. Press the [REC PAUSE/START] button to changed over VACS
on/off.
8. Press the
I/1
button to release from this mode, then cold reset
is performed.
Ver. 1.1
Page of 86
Display

Click on the first or last page to see other HCD-RG295 / HCD-RG495 / HCD-RG595 / MHC-RG295 / MHC-RG495 / MHC-RG595 service manuals if exist.