21
SECTION  3
TEST  MODE
[COLD  RESET]
•  The cold reset clears all data including preset data stored in the 
RAM to initial conditions. Execute this mode when returning 
the set to the customer.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2. Press 
the 
[
x
] button, [DISC 3] button and [
?/1
] button simul-
taneously.
3.  The message “COLD RESET” appears on the LCD module. 
Then, the LCD module becomes blank for a while, and the 
system is reset.
[COMMON  TEST  MODE]
•  This mode is used to check operations of the respective section 
of Equalizer level, volume and VACS ON/OFF.
Procedure:
•  To enter Common Test Mode
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [
x
] button, [PRESET EQ] button and [DISC 1] si-
multaneously.
3.  The message “VACS0” appears on the LCD module.
•  Check of Equalizer Level
1.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “ALL EQ MIN” appears on the LCD module. GEQ 
decreases to its minimum.
2.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “ALL EQ MAX” appears on the LCD module. GEQ 
increases to its maximum.
3.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “ALL EQ FLAT” appears on the LCD module. GEQ 
is set to fl at.
•  Check of Volume
1.  Press the [USB] button repeatedly, the sound volume increases 
to its maximum and message “VOLUME16” t “VOLUME 
MAX” appears on the LCD module.
2.  Press the [OPTIONS] button repeatedly, the sound volume 
decreases to its minimum and message “VOLUME16” t 
“VOLUME MIN” appears on the LCD module.
•  Check of VACS (Variable Attenuation Control System)
ON/OFF Select
1.  Press the [REC TO USB] button repeatedly until a message 
“VACS OFF” or “VACS ON” appears on the LCD module.
•  To release from Common Test Mode
1.  To release from this mode, press the [
?/1
] button.
2.  To cold reset is enforced at the same time.
[AMP  TEST  MODE]
•  This mode is used to display the real time VACS level and 
check operations of the respective sections of Equalizer band 
and DBFB ON/OFF.
Procedure:
•  To enter AMP Test Mode
1.  Press the [
?/1
] button to turn on the system.
2. Press the [
x
] button, [GROOVE] button and [DISC 1] button 
simultaneously.
3.  The message “AMP TEST IN” appears on the LCD module.
•  Check of VACS Display/AMP Adjustment Select
1.  Press the [REC TO USB] button repeatedly until a message 
“V0 0 0” appears on the LCD module. “0” represents VACS 
level which is triggered by signal level.
2.  Press the [REC TO USB] button repeatedly until a message 
“D +4 0 +2” appears on the LCD module. “+4” represents 
Equalizer Low level, “0” represents Equalizer Mid level and 
“+2” represents Equalizer High level.
•  Check of Equalizer Band Select
1.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “LOW +4 dB” appears on the LCD module. EQ Band 
is set to Low level.
2.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “MID 0 dB” appears on the LCD module. EQ Band is 
set to Middle level.
3.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “HIGH +2 dB” appears on the LCD module. EQ Band 
is set to High level.
•  Change of Equalizer Band
1.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “LOW +4 dB” appears on the LCD modulel.
2.  When the [OPERATION DIAL] ring is turned clockwise or 
counterclockwise even slightly, “LOW +4 dB” change to 
“LOW –8 dB” y “LOW +8 dB” appears on the LCD mod-
ule.
3.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “MID 0 dB” appears on the LCD module.
4.  When the [OPERATION DIAL] ring is turned clockwise or 
counterclockwise even slightly, “MID 0 dB” change to “MID 
–8 dB” y “MID +8 dB” appears on the LCD module.
5.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “HIGH +2 dB” appears on the LCD module.
6.  When the [OPERATION DIAL] ring is turned clockwise or 
counterclockwise even slightly, “HIGH +2 dB” change to 
“HIGH –8 dB” y “HIGH +8 dB” appears on the LCD mod-
ule.
•  Check of DBFB ON/OFF Select
1.  Press the [OPTIONS] button repeatedly until a message 
“DBFB OFF” or “DBFB ON” appears on the LCD module.
•  To release from AMP Test Mode
1.  To release from this mode, press the [
?/1
] button.
HCD-GZR888DA/GZR999DA
22
[TCM  OFF  LINE  MODE]
(Except E2, E51, MX Model)
•  This mode prevents the system from tuning off automatically 
when TCM is not connected. Therefore, measurements can be 
done even when TCM is not connected during production.
Procedure:
1.  Press the [
?/1
] button to turn off the system and enter the 
clock display or demonstration mode.
2.  Press the [REC TO TAPE] button, [DISC 3] button and [
?/1
button simultaneously. The system will turn on automatically.
3.  The message “TAPE MECHA OFF LINE” appears on the 
LCD module.
•  To release from TCM OFF LINE Mode
1.  To release from this mode, press the [
?/1
] button.
[PANEL  TEST  MODE]
•  This mode is used to check the LCD module, LEDs, button, 
MASTER VOLUME dial, OPERATION DIAL ring, system 
software version, DVD lib version, model name and destina-
tion.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [
x
] button, [DISC 3] button and [USB] button simul-
taneously.
3.  Power illuminator LEDs and segment in LCD module are 
lighted up.
4.  When you want to enter to the system software version display 
model, press the [DISC 1] button. The system software version 
appears on the LCD module.
 
Press the [DISC 1] button again, the DVD lib version appears 
on the LCD module.
5.  Press the [DISC 2] button the mode name and destination on 
the LCD module.
6.  Press the [DISC 3] button the key encode test mode is acti-
vated.
7.  In the key encode test mode, the LCD module displays “KEY 
0 0 0 0 0”. 
 
Each time a button pressed, change the each numbers.
•  To release from Panal Test Mode
1.  To release from this mode, press the [
x
] button, [DISC 3] but-
ton and [USB] button simultaneously.
[DVD  SHIP  MODE (WITHOUT  MEMORY  CLEAR)]
•  This mode moves the optical pick-up to the position durable 
to vibration. Use this mode when returning the set to the cus-
tomer after repair.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button, to set the “NO DISC” mode.
3.  Press the [
N
] button and [
?/1
] button simultaneously.
 
The system will turn off automatically.
4.  After the “STANDBY” blinking display fi nishes, a message 
“LOCK” appears on the LCD module and the DVD ship mode 
is set.
•  To release from DVD Ship Mode
1.  To release from this mode, press the [
?/1
] button.
[DVD  SHIP  MODE (WITH  MEMORY  CLEAR)]
•  This mode moves the optical pick-up to the position durable 
to vibration and clears all data including preset data stored in 
the RAM to initial conditions after the power supply is turned 
off. Use this mode when returning the set to the customer after 
repair.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button, to set the “NO DISC” mode.
3.  Press the [TUNING –] button, [DISC 3] button and [
?/1
] but-
ton simultaneously.
4.  After the “STANDBY” blinking display fi nishes, a message 
“COLD RESET” appears on the LCD module and the DVD 
ship mode is set.
•  To release from DVD Ship Mode
1.  To release from this mode, press the [
?/1
] button.
[DISC  THEFT  PREVENTION  MODE]
•  This mode let you lock the disc tray. When this mode is acti-
vated, the disc tray will not open.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button.
3. Press the [
x
] button and [OPEN/CLOSE 
Z
] button simulta-
neously and hold down until “LOCKED” or “UNLOCKED” 
appears on the LCD module (around 5 seconds).
•  To release from Disc Theft Prevention Mode
1.  This mode will not be deselected only by turning the power 
off. To exit from the mode, perform the above item 3 again.
[DVD  COLOR  SYSTEM  MODE]
•  This mode let you change the color system of the video output 
from PAL to NTSC or vice-versa.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button.
3.  Press the [
?/1
] button to turn off the system.
4.  Press the [DISPLAY] button to switch the mode the clock dis-
play or demonstration mode.
5.  Press the [
X
] button and [
?/1
] button simultaneously.
 
The system will turn on automatically.
6.  The message “COLOR PAL” or “COLOR NTSC” appears on 
the LCD module.
•  To release from DVD Color System Mode
1.  Once the color system has been selected, the mode is fi xed 
there after. If you wish to change the mode again, perform the 
above item 4 again.
[DVD  FIRMWARE  VERSION  MODE]
•  This mode is used to display the DVD fi rmware version.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button.
3  Press the [
?/1
] button to turn off the system and enter the 
clock display or demonstration mode.
4.  Press the [
x
] button and [
?/1
] button simultaneously.
5.  The version of DVD fi rmware appears on the on-screen dis-
play on TV.
• Abbreviation
  E2 
: 120V AC area in E model
  E51 
: Chilean and Peruvian models
  MX 
: Mexican model
HCD-GZR888DA/GZR999DA
23
•  To release from DVD Firmware Version Mode
1.  To release from this mode, press the [
?/1
] button.
[MTK  REBOOT  AVOIDANCE  MODE]
•  This mode is used to display the MTK Reboot Avoidance.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button.
3.  Press the [DVD] button, [OPEN/CLOSE 
Z
] button and [TUN-
ING +] button simultaneously.
4.  The message “MTK DBG” appears on the LCD module.
•  To release from MTK Reboot Avoidance Mode
1.  To release from this mode, press the [
?/1
] button.
[AM  TUNER  STEP  CHANGE]
•  The step interval of AM channels can be toggled between 9 
kHz and 10 kHz.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [TUNER/BAND] button repeatedly to select the 
“AM”.
3.  Press the [
?/1
] button to turn off the system.
4.  Press the [TUNING +] button and [
?/1
] button simultane-
ously. The system will turn on automatically.
5.  The message “AM 9K STEP” or “AM 10K STEP” appears on 
the LCD module and thus the channel step change.
[VIDEO/SAT  FUNCTION  CHANGE]
•  This mode let you change from VIDEO to SAT and vice-versa.
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [VIDEO/SAT] button.
3.  Press the [VIDEO/SAT] button and [
x
] button simultaneously. 
The function will change to SAT.
4.  Press the same button again to change from SAT to VIDEO.
[DVD  SERVICE  MODE]
•  This mode let you make diagnosis and adjustment easily by 
using the remote commander and the TV. The instructions, di-
agnostic results, etc. are given on the on-screen display.
•  TEST DISC LIST
 
Be sure to use the DVD disc that matches the signal standards 
of your region.
• CD
   
 
  YEDS-18  (Part No.: 3-702-101-01)
   
 
  PATD-012  (Part No.: 4-225-203-01)
•  DVD SL (Single Layer)
   
NTSC : HLX-503  (Part No.: J-6090-069-A)
   
 
  HLX-504  (Part No.: J-6090-088-A)
   
PAL  : HLX-506  (Part No.: J-6090-077-A)
•  DVD DL (Double Layer)
   
NTSC : HLX-501  (Part No.: J-6090-071-A)
   
 
  HLX-505  (Part No.: J-6090-089-A)
   
PAL  : HLX-507  (Part No.: J-6090-078-A)
•  Procedure to enter to DVD Service Mode:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD] button.
3. Press 
the 
[
x
] button and [OPEN/CLOSE 
Z
] button simultane-
ously and then turn the [MASTER VOLUME] dial clockwise.
4.  The message “SERVICE IN” appears on the LCD module and 
the Top Menu of Remocon Diagnosis Menu appears on the on-
screen display on the TV. The model name, main unit’s micom 
version information (IF-con) and DVD fi rmware version infor-
mation (Syscon) are displayed at the bottom of the on-screen 
display.
 
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
IF-con
Syscon
: SVX5DS_ME
: Ver.  01.00 (0000)
: Ver.  1.200
5.  To execute each function, press its number by using numeric 
button on the remote commander.
6.  To release from this mode, press the [
?/1
] button to turn off 
the system.
•  Execute IOP Measurement
 
In order to execute IOP measurement, the following standard 
procedures must be followed.
1.  From the Top Menu of Remocon Diagnosis Menu, select “2. 
Drive Manual Operation” by pressing the [2] button on the 
remote commander. The following screen appears on the on-
screen display.
 
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
2.  Select “3. Manual Adjustment” by pressing the [3] button on 
the remote commander. The following screen appears on the 
on-screen display.
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
 
o Change Value
RETURN  Return to previous menu
HCD-GZR888DA/GZR999DA
24
3.  Select “6. Iop:” by pressing the [6] button on the remote com-
mander.
4.  Wait until a hexadecimal number appears in the on-screen dis-
play as below:
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop. ED
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
 
o Change Value
RETURN  Return to previous menu
5.  Convert data from hexadecimal to decimal by using conver-
sion table.
6. Please 
fi nd the label on the rear of the BU (Base Unit).
 
The default IOP value is written in the label.
7.  Subtract between these two values.
8.  If the remainder is smaller than 93 (decimal), then it is OK.
 
However if the value is higher than 93, then the BU is defec-
tive and need to be change.
9.  Press the [RETURN] button on the remote commander to re-
turn to previous menu.
10. Press the [0] button on the remote commander to return to the 
Top Menu of Remocon Diagnosis Menu.
11.  Press the [
?/1
] button to turn off the system.
•  Check Emergency History
 
To check the emergency history, please follow the following 
procedure.
1.  From the Top Menu of Remocon Diagnosis Menu, select “3. 
Emergency History” by pressing the [3] button on the remote 
commander. The following screen appears on the on-screen 
display.
 
Emg. History Check
1.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
2.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
Next   Next Page
Prev   Prev Page
O  Return to Top Menu
2.  You can check the total time when the laser is turned on during 
playback of DVD and CD from the above menu. The maxi-
mum time, which can be displayed are 999h 59min.
3.  You can check the error code of latest 10 emergency history 
from the above menu. To view the previous or next page of 
emergency history, press the [
.
] button or [
>
] button 
 
on the remote commander. The error code consists of
• Error 
Code
 
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
 
The meaning of error code is as below:
 
01: Communication error (No reply from syscon)
 
02: Syscon hung up
 
03: Power OFF request when syscon hung up
 19: 
Thermal 
shutdown
 
24: MoveSledHome error
 
25: Mechanical move error (5 Changer)
 
26: Mechanical move stack error
 
30: DC motor adjustment error
 
31: DPD offset adjustment error
 
32: TE balance adjustment error
 
33: TE sensor adjustment error
 
34: TE loop gain adjustment error
 
35: FE loop gain adjustment error
 
36: Bad jitter after adjustment
 
40: Focus NG
 
42: Focus layer jump NG
 
51: Spindle stop error
 
52: Open kick spindle error
 
60: Focus on error
 
61: Seek fail error
 
62: Read Q data/ID error
 
70: Lead in data read fail
 
71: TOC read time out (CD)
 
80: Can’t buffering
 
81: Unknown media type
•  Parameter of error code
 
This is the detail of error code.
 
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
•  Time of error code
 
This is the laser time when an error occurred.
 
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
To clear the Laser Hours
Press the [  DISPLAY] button and then press the [CLEAR] but-
ton. The data for both CD and DVD data are reset.
 
Emg. History Check
1.  01  05  04  04
Laser Hours
CD
0h
0min
DVD
0h
0min
00  92  46  00
00  00  00  00
00  00  23  45
2.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
Next   Next Page
Prev  Prev Page
O  Return to Top Menu
Page of 116
Display

Click on the first or last page to see other HCD-GZR888DA / HCD-GZR999DA service manuals if exist.