HCD-GZR888D/GZR999D
25
To clear the Emergency History
Press the [DVD TOP MENU] button and then press the [CLEAR]
button.
The error code for all emergency history would be reset.
Emg. History Check
1.  00  00  00  00
Laser Hours
CD
999h
59min
DVD
999h
59min
00  00  00  00
00  00  00  00
00  00  00  00
2.  00  00  00  00
00  00  00  00
00  00  00  00
00  00  00  00
Next   Next Page
Prev   Prev Page
O  Return to Top Menu
To clear the Initialize Setup Data
Press  the  [DVD/TUNER  MENU]  button  and  then  press  the
[CLEAR] button on the remote commander.
Emg. History Check
Initialize  setup data...
Laser Hours
CD
999h
59min
DVD
999h
59min
Next   Next Page
Prev   Prev Page
O  Return to Top Menu
To return to the Top Menu of Remocon Diagnosis Menu
Press the [0] button on the remote commander.
•  Check Version Information
To check the version information, please follow the following
procedure.
1.  From the Top Menu of Remocon Diagnosis Menu, select “4.
Version information” by pressing the [4] button on the remote
commander.  The  following  screen  appears  on  the  on-screen
display.
Version information
O  Return to Top Menu
Firm (Main) :  Ver. xxxxx
Firm (Sub) :  xxxxx
RISC :   xxxxx
8032 :   xxxxx
Audio DSP :  xxxxx
Servo DSP :  xxxxx
To return to the Top Menu of Remocon Diagnosis Menu, press
the [0] button on the remote commander.
HCD-GZR888D/GZR999D
26
SECTION  4
MECHANICAL  ADJUSTMENTS
Except E2, E51, AR, MX Model:
Precaution
1.  Clean the following parts with a denatured alcohol-moistened
swab:
record/playback head
pinch roller
erase head
rubber belts
capstan
idler
2.  Demagnetize the record/playback head with a head demagne-
tizer.
3.  Do not use a magnetized screwdriver for the adjustments.
4.  After the adjustments, apply suitable locking compound to the
parts adjusted.
5.  The  adjustments  should  be  performed  with  the  rated  power
supply voltage unless otherwise noted.
Torque Measurement
Mode
Torque meter
Meter reading
FWD
CQ-102C
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 to 0.98 oz • inch)
FWD
back tension
CQ-102C
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 to 0.08 oz • inch)
FF/REW
CQ-201B
6.96 N • m to 14.02 N • m
71 to 143 g • cm
(0.98 to 1.99 oz • inch)
FWD tension
CQ-403A
9.80 N • m
100 g or more
(3.53 oz or more)
HCD-GZR888D/GZR999D
27
SECTION  5
ELECTRICAL  ADJUSTMENTS
DVD  SECTION
When the optical pick-up assy is replaced, perform the “Execute 
IOP Measurement”.
 
Execute IOP Measurement (See page 23)
[TEST  DISC  LIST]
Be sure to use the DVD disc that matches the signal standards of 
your region.
•  CD
     
  YEDS-18 
(Part No.: 3-702-101-01)
     
  PATD-012  (Part No.: 4-225-203-01)
•  DVD SL (Single Layer)
    NTSC  :  HLX-503 
(Part No.: J-6090-069-A)
     
  HLX-504 
(Part No.: J-6090-088-A)
    PAL  :  HLX-506 
(Part No.: J-6090-077-A)
•  DVD DL (Double Layer)
    NTSC  :  HLX-501 
(Part No.: J-6090-071-A)
     
  HLX-505 
(Part No.: J-6090-089-A)
    PAL  :  HLX-507 
(Part No.: J-6090-078-A)
[RFMON Level Check]
Connection:
+
CN105 pin 6 (RFMON)
CN105 pin 3 (GND)
oscilloscope 
DMB19 board
Procedure:
1.  Connect  an  oscilloscope  to  CN105  pin  6  (RFMON)  and 
CN105 pin 3 (GND) on the DMB19 board.
2.  Turn the power on.
3.  Set the test disc (refer to the TEST DISC LIST) on the tray and 
press the [
N
] button to playback.
4.  Confirm  that  oscilloscope  waveform  is  clear  and  check  RF-
MON signal level is correct or not.
Note:  A clear RFMON signal waveform means that the shape “◊” can be 
clearly distinguished at the center of the waveform.
RFMON signal waveform
VOLT/DIV: 200 mV
TIME/DIV: 500 nS
level: 0.58 ± 1.23 Vp-p (DVD)
         0.57 ± 1.1 Vp-p (CD)
Checking Location: DMB19 board (Side A)
CN105 pin 3
(GND)
CN105 pin 6
(RFMON)
– DMB19 BOARD (SIDE A) –
IC104
CN105
CN1104
IC101
CN1
103
TUNER  SECTION
FM Tune Level Check
set
signal 
generator
Procedure:
1.  Turn on the set.
2.  Input the following signal from signal generator to FM antenna 
input directly.
Carrier frequency: A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation  : 75 kHz
Modulation  : 1 kHz
ANT input  : 35 dB
m (EMF)
Note:  Use 75 ohm coaxial cable to connect signal generator and the set.
 
  You cannot use video cable for checking.
 
  Use signal generator whose output impedance is 75 ohm.
3.  Set to FM tuner function and tune A, B and C signals.
4.  Confirm “TUNED” is lit on the display for A, B and C signals.
When  the  selected  station  signal  is  received  in  good  condition, 
“TUNED” is displayed.
HCD-GZR888D/GZR999D
28
screw
position
L-CH
peak
within
1 dB
output
level
L-CH
peak
R-CH
peak
within
1 dB
screw
position
R-CH
peak
DECK  SECTION
VIDEO  SECTION
0 dB = 0.775V
Video Level Check (VIDEO BOARD)
Purpose
This adjustment is made to satisfy the NTSC standard, and if not 
adjusted correctly, the brightness will be too large or small.
oscilloscope
set
J1502
VIDEO OUT
75  
+
Procedure:
1.  Connect oscilloscope to VIDEO OUT jack.
2.  Load a DVD reference disc playback.
3.  Check the video signal level is 1.00±0.07Vp-p.
1.00 ± 0.07 Vp-p
(WHITE 100%)
Except E2, E51, AR, MX Model:
1.  Demagnetize the record/playback head with a head demagne-
tizer.
2.  Do not use a magnetized screwdriver for the adjustments.
3.  After the adjustments, apply suitable locking compound to the 
parts adjust.
4.  The  adjustments  should  be  performed  with  the  rated  power 
supply voltage unless otherwise noted.
5.  The adjustments should be performed in the order given in this 
service manual. (As a general rule, playback circuit adjustment 
should be completed before performing recording circuit ad-
justment.)
6.  The  adjustments  should  be  performed  for  both  L-CH  and 
R-CH.
7.  Switches and controls should be set as follows unless other-
wise specified.
•  Test Tape
Tape
Signal
Used for
P-4-A063
6.3 kHz, –10 dB
Azimuth Adjustment
Record/Playback Head Azimuth Adjustment
Procedure:
1.  Mode:  Playback
+
level meter
test tape
P-4-A063
(6.3 kHz, –10 dB)
MAIN board
IC101
pin wh (L-CH)
pin ql (R-CH)
MAIN board
IC101
pin t; (GND)
2.  Turn the adjustment screw and check output peaks. If the peaks 
do not match for L-CH and R-CH, turn the adjustment screw 
so that outputs match within 1dB of peak.
Page of 108