Sony HCD-GTR6 / HCD-GTR6B / HCD-GTR7 / HCD-GTR8 / HCD-GTR8B / MHC-GTR6 / MHC-GTR8 Service Manual ▷ View online
17
HCD-GTR6/GTR6B/GTR7/GTR8/GTR8B
SECTION 2
TEST MODE
4. When the [VOLUME] knob is turned clockwise even slightly,
the sound volume increases to its maximum and a message
“VOLUME MAX” appears on the fl uorescent indicator tube.
“VOLUME MAX” appears on the fl uorescent indicator tube.
5. When the [VOLUME] knob is turned counterclockwise even
slightly, the sound volume decreases to its minimum and a
message “VOLUME MIN” appears on the fl uorescent indica-
tor tube.
message “VOLUME MIN” appears on the fl uorescent indica-
tor tube.
•
Tape function (only for HCD-GTR6B/GTR8B)
1. Inserted a tape in deck. The function is changed to VIDEO
automatically when the recording is started by pressing [REC
TO TAPE] then press [ENTER] button. During recording the
ALC (Automatic Logic Control) is turned on.
TO TAPE] then press [ENTER] button. During recording the
ALC (Automatic Logic Control) is turned on.
2. During recording, press ALBUM - will stop the recording
and the function is changed to TAPE and rewind the tape in
Deck until the recording start position and playback of the
tape in Deck is started.
Deck until the recording start position and playback of the
tape in Deck is started.
•
To release from MC Test mode
1. To release from this mode, press [POWER] button.
2. The cold reset is enforced at the same time.
2. The cold reset is enforced at the same time.
[COLD RESET]
• The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning the
set to the customer.
set to the customer.
Procedure:
1. Press [x] button, [ENTER] button, and [POWER] button si-
1. Press [x] button, [ENTER] button, and [POWER] button si-
multaneously.
2. The
fl uorescent indicator tube becomes blank for a while, and
the set is reset.
[VACS ON/OFF]
• This mode is used to switch ON and OFF the VACS (Variable
Attenuation Control System).
Procedure:
1. Press [POWER] button to turn the set ON.
2. Press [x] button and [OPTIONS] button simultaneously. The
1. Press [POWER] button to turn the set ON.
2. Press [x] button and [OPTIONS] button simultaneously. The
message “VACS OFF” or “VACS ON” appears on the fl uores-
cent indicator tube.
cent indicator tube.
[TUNER STEP CHANGE]
• The step interval of AM channels can be toggled between 9 KHz
and 10 KHz. This mode is not available for Saudi Arabian mod-
els.
els.
Procedure:
1. Press [POWER] button to turn the set ON.
2. Press [TUNER/BAND] / [TUNER AM] button to select the
1. Press [POWER] button to turn the set ON.
2. Press [TUNER/BAND] / [TUNER AM] button to select the
“AM”.
3. Press [POWER] button to turn the set OFF.
4. Press [ENTER] button and [POWER] button simultaneously.
4. Press [ENTER] button and [POWER] button simultaneously.
The system will turn ON automatically. The message “AM
9K STEP” or “AM 10K STEP” appears on the fl uorescent in-
dicator tube and thus the channel step is changed.
9K STEP” or “AM 10K STEP” appears on the fl uorescent in-
dicator tube and thus the channel step is changed.
[GC TEST MODE]
• This mode is used to check the fl uorescent indicator tube, LEDs,
keys, VOLUME jog, OPERATION DIAL jog, model, destination
and software version.
and software version.
Procedure:
1. Press [x] button, [ENTER] button and [DISC 2] button si-
1. Press [x] button, [ENTER] button and [DISC 2] button si-
multaneously.
2. All LEDs and segments in fl uorescent indicator tube are light-
ed up. All LEDs are lighted up in red color except for [
B]
LED where the LED is lighted up in red and blue color,
[
A] LED in blue color and SUBWOOFER ON/OFF in
green color.
3. When you want to enter to the model version and destination
display mode, press [DISC 1] button. The model information
appears on the fl uorescent indicator tube.
appears on the fl uorescent indicator tube.
4. Each time [DISC 1] button is pressed, the display changes to
display software version and date of the software creation.
The sequence is model destination, SC, MDK, GC, SYS, CD,
CDMA, CDMB, ST, TC, TA, TM and MTR in this order, and
returns to the model destination display.
The sequence is model destination, SC, MDK, GC, SYS, CD,
CDMA, CDMB, ST, TC, TA, TM and MTR in this order, and
returns to the model destination display.
5. Press [DISC 2] button, the key check mode is activated.
6. In the key check mode, the fl uorescent indicator tube displays
6. In the key check mode, the fl uorescent indicator tube displays
“K 0 J0 V0”.
Turn the [OPERATIONAL DIAL] clockwise; ”J” value in-
creases by one. Turn the [OPERATIONAL DIAL] counter-
clockwise; “J” value decreases by one. Each time a button is
pressed, “K” value increases. Press other keys on main unit
to check whether the key is detected. However, once a button
has been pressed, it is no longer taken into account.
creases by one. Turn the [OPERATIONAL DIAL] counter-
clockwise; “J” value decreases by one. Each time a button is
pressed, “K” value increases. Press other keys on main unit
to check whether the key is detected. However, once a button
has been pressed, it is no longer taken into account.
“V” value increases in the manner of 0,1, 2, 3 ... if [VOLUME]
knob is turned clockwise, or it decreases in the manner of 0, 9,
8, 7 ... if [VOLUME] knob is turned counterclockwise.
knob is turned clockwise, or it decreases in the manner of 0, 9,
8, 7 ... if [VOLUME] knob is turned counterclockwise.
7. When [DISC SKIP/EX-CHANGE] button is pressed after
all LEDs and segments in fl uorescent indicator tube light
up, alternate segments in fl uorescent indicator tube and LED
would light up. If you press [DISC SKIP/EX-CHANGE] but-
ton again, another half of alternate segments in fl uorescent
indicator tube and LED would light up. Press [DISC SKIP/
EX-CHANGE] button again would cause all segments will
lights off and press [DISC SKIP/EX-CHANGE] button again
all segments will lights up.
up, alternate segments in fl uorescent indicator tube and LED
would light up. If you press [DISC SKIP/EX-CHANGE] but-
ton again, another half of alternate segments in fl uorescent
indicator tube and LED would light up. Press [DISC SKIP/
EX-CHANGE] button again would cause all segments will
lights off and press [DISC SKIP/EX-CHANGE] button again
all segments will lights up.
8. To release from this mode, press three buttons in the same
manner as step 1, or disconnect the power cord.
[MC TEST MOD E]
• This mode is used to check operations of the respective sections
of Amplifi er and Tape.
Procedure:
• To enter MC Test Mode
1. Press [x] button, [ENTER] button and [DISC 3] button si-
• To enter MC Test Mode
1. Press [x] button, [ENTER] button and [DISC 3] button si-
multaneously.
2. The CD number indicators fl ash on the fl uorescent indicator
tube. The function is changed to VIDEO.
•
Check of Amplifi er
1. Press [EQ BAND] button repeatedly until a message “GEQ
MAX” appears on the fl uorescent indicator tube. GEQ in-
creases to its maximum.
creases to its maximum.
2. Press [EQ BAND] button repeatedly until a message “GEQ
MIN” appears on the fl uorescent indicator tube. GEQ de-
creases to its minimum.
creases to its minimum.
3. Press [EQ BAND] button repeatedly until a message “GEQ
FLAT” appears on the fl uorescent indicator tube. GEQ is set
to fl at.
to fl at.
18
HCD-GTR6/GTR6B/GTR7/GTR8/GTR8B
[CD SHIP MODE (WITH MEMORY CLEAR)]
• This mode moves the optical pick-up to the position durable to
vibration and clears all data including preset data stored in the
RAM to initial conditions. Use this mode when returning the set
to the customer after repair.
RAM to initial conditions. Use this mode when returning the set
to the customer after repair.
Procedure:
1. Press [POWER] button to turn the set ON.
2. Select CD function and waiting until CD no disc confi rm.
3. Press [x] button, [SOUND FLASH] button and [POWER]
1. Press [POWER] button to turn the set ON.
2. Select CD function and waiting until CD no disc confi rm.
3. Press [x] button, [SOUND FLASH] button and [POWER]
button simultaneously. The set will power off automatically.
4. After the “STANDBY” blinking display fi nishes, a message
“MECHA LOCK” is displayed on the fl uorescent indicator
“MECHA LOCK” is displayed on the fl uorescent indicator
tube and the CD ship mode is set.
5. Then AC power OFF.
[CD SHIP MODE (WITHOUT MEMORY CLEAR)]
• This mode moves the optical pick-up to the position durable to
vibration. Use this mode when returning the set to the customer
after repair.
after repair.
Procedure:
1. Press [POWER] button to turn the set ON.
2. Select CD function.
3. Press [CD] button and [POWER] button simultaneously. The
1. Press [POWER] button to turn the set ON.
2. Select CD function.
3. Press [CD] button and [POWER] button simultaneously. The
set will power off automatically.
4. After the “STANDBY” blinking display fi nishes, a message
“MECHA LOCK” is displayed on the fl uorescent indicator
tube and the CD ship mode is set.
tube and the CD ship mode is set.
5. The AC power OFF.
[CD TRAY LOCK MODE / DISC THEFT
PREVENTION]
PREVENTION]
• This mode let you lock the disc tray. When this mode is activated,
the disc tray will not open when [OPEN/CLOSE] button or [EX-
CHANGE] button is pressed. The message “LOCKED” will be
displayed on the fl uorescent indicator tube.
CHANGE] button is pressed. The message “LOCKED” will be
displayed on the fl uorescent indicator tube.
Procedure:
1. Press [POWER] button to turn the set ON.
2. Select CD function.
3. Press [x] button and [OPEN/CLOSE] button simultaneously
1. Press [POWER] button to turn the set ON.
2. Select CD function.
3. Press [x] button and [OPEN/CLOSE] button simultaneously
and hold down until “LOCKED” or “UNLOCKED” dis-
played on the fl uorescent indicator tube (around 5 seconds).
played on the fl uorescent indicator tube (around 5 seconds).
[TCM OFFLINE MODE]
(only for HCD-GTR6B/GTR8B)
(only for HCD-GTR6B/GTR8B)
• This mode prevents set from power off automatically when TCM
is not connected. Therefore, measurements can be done even when
TCM is not connected.
TCM is not connected.
Procedure:
1. When the system in turned off, press [EQ BAND/MEMORY]
1. When the system in turned off, press [EQ BAND/MEMORY]
button, [STOP] button and [POWER] button simultaneously.
The set will power on automatically.
The set will power on automatically.
2. The message “TCM OFFLINE” will be displayed on the fl uo-
rescent indicator tube.
[VACS DISPLAY]
• This mode is used to check the VACS level.
Procedure:
1. Press [POWER] button to turn on the system.
2. Press [x] button, [SOUND FLASH] button and [DISC SKIP/
1. Press [POWER] button to turn on the system.
2. Press [x] button, [SOUND FLASH] button and [DISC SKIP/
EX-CHANGE] button simultaneously.
3. The VACS Level Display, the fl uorescent indicator tube dis-
plays “VATB F APC”. “V” represent VACS , A represent
VACS level which is triggered by signal level, “T” represent
Thermal VACS NEO, B represent VACS level which is trig-
gered by temperature, “F” represent FAN is triggered by
software to turn in to high speed, “AP” represent APVACS
(Abuse Protection VACS) and “C” represent APVACS level
which is triggered.
VACS level which is triggered by signal level, “T” represent
Thermal VACS NEO, B represent VACS level which is trig-
gered by temperature, “F” represent FAN is triggered by
software to turn in to high speed, “AP” represent APVACS
(Abuse Protection VACS) and “C” represent APVACS level
which is triggered.
[METER AGING TEST MODE]
• This mode use in factory to perform the non-stop aging mode for
meter device.
Procedure:
1. Press [POWER] button to turn on the system.
2. Press [EQ BAND/MEMORY] button and [METER MODE]
1. Press [POWER] button to turn on the system.
2. Press [EQ BAND/MEMORY] button and [METER MODE]
button simultaneously.
[ERROR MESSAGE]
1. METER ERROR CODE CHECK
1. METER ERROR CODE CHECK
• This mode is used to check the number of trigger for Meter Pointer
to initial switch and end switch. The switches will trigger during
meter initialize in AC supply on condition.
meter initialize in AC supply on condition.
Procedure:
1. Press [POWER] button to turn on the system.
2. Press [x] button, [EQ BAND/MEMORY] button and [ME-
1. Press [POWER] button to turn on the system.
2. Press [x] button, [EQ BAND/MEMORY] button and [ME-
TER MODE] button simultaneously.
The Meter Error Code will appear on the fl uorescent indicator
tube displays
tube displays
• Display
Display on fl uorescent indicator tube,
IxxxxxMyyyyy
Ixxxxx = total number of Initial Switch touch by Meter
pointer. The Initial Switch will touch twice during meter
initialized process.
pointer. The Initial Switch will touch twice during meter
initialized process.
Myyyyy = total number of End Switch touch by Meter
pointer. The End Switch will touch one times during meter
initialized process.
pointer. The End Switch will touch one times during meter
initialized process.
19
HCD-GTR6/GTR6B/GTR7/GTR8/GTR8B
(only for HCD-GTR6B/GTR8B)
Precaution
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
2.9m N • m to 6.9m N • m
FWD
CQ-102C
30 to 70 g • cm
(0.42 – 0.97 oz • inch)
FWD
0.15m N • m to 0.59m N • m
back tension
CQ-102C
2 to 6 g • cm
(0.03 – 0.08 oz • inch)
2.9m N • m to 6.9m N • m
REV
CQ-102RC
30 to 70 g • cm
(0.42 – 0.97 oz • inch)
0.15m N • m to 0.59m N • m
REV
CQ-102RC
2 to 6 g • cm
back tension
(0.03 – 0.08 oz • inch)
4.8m N • m to 16.7m N • m
FF/REW
CQ-201B
49 to 170 g • cm
(0.68 – 2.36 oz • inch)
Mode
Torque meter
Meter reading
SECTION 3
MECHANICAL ADJUSTMENTS
20
HCD-GTR6/GTR6B/GTR7/GTR8/GTR8B
[FM Tune Level Check]
Procedure:
1. Turn the power on.
2. Input the following signal from Signal Generator to FM an-
2. Input the following signal from Signal Generator to FM an-
tenna input directly.
* Carrier Freq : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation : 75 kHz
Modulation : 1 kHz
ANT input : 35 dBu (EMF)
Note: Please use 75 ohm “coaxial cable” to connect SG and the set. You
cannot use video cable for checking.
Please use SG whose output impedance is 75 ohm.
3. Set to FM tuner function and tune A, B and C signals.
4. Confi rm “TUNED” is lit on the display for A, B and C sig-
4. Confi rm “TUNED” is lit on the display for A, B and C sig-
nals.
The mark of “TUNED” means “The selected station signal is
received in good condition.”
received in good condition.”
FM signal generator
OUT (75
7)
SET
SECTION 4
ELECTRICAL ADJUSTMENTS
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual. (As a general rule, playback circuit adjust-
ment should be completed before performing recording circuit
adjustment.)
ment should be completed before performing recording circuit
adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless otherwise
specifi ed.
• Test Tape
[RECORD/PLAYBACK HEAD AZIMUTH
ADJUST-MENT]
ADJUST-MENT]
Note: Perform this adjustments for Single deck
Procedure:
1. Mode: Playback
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
so that outputs match within 1dB of peak.
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
set
+
–
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
P-4-A100
(10 kHz, –10 dB)
(L-CH & R-CH)
screw
position
position
L-CH
peak
peak
within
1dB
1dB
output
level
level
L-CH
peak
peak
R-CH
peak
peak
within
1dB
1dB
screw
position
position
R-CH
peak
peak
TUNER SECTION
0 dB = 1 µV
DECK SECTION
0 dB = 0.775 V
(only for HCD-GTR6B/GTR8B)
Click on the first or last page to see other HCD-GTR6 / HCD-GTR6B / HCD-GTR7 / HCD-GTR8 / HCD-GTR8B / MHC-GTR6 / MHC-GTR8 service manuals if exist.