3-12. OPTICAL PICK-UP BLOCK (KSM-213D)
3-13. SENSOR BOARD
two coil springs
(insulator)
(insulator)
two coil springs
(insulator)
(insulator)
two insulators
two insulators
two floating screws
(PTPWH
(PTPWH
M2.6)
holder (213) assy or holder (KSM) assy
Remove the four solders of motor.
RB flexible flat cable (16 core)
(CN301)
(CN301)
RT CD board
RE optical pick-up block
(KSM-213D)
(KSM-213D)
floating screw
(PTPWH
(PTPWH
M2.6)
two floating screws
(PTPWH
(PTPWH
M2.6)
tray
belt (table)
pulley (table)
screw
(BTTP
(BTTP
(M2.6))
SENSOR board
gear (geneva)
connector
(CN731)
(CN731)
floating screw
(PTPWH
(PTPWH
M2.6)
floating screw
(PTPWH
(PTPWH
M2.6)
floating screw
(PTPWH
(PTPWH
M2.6)
HCD-GT220/GT440/GT660
14
3-14. MOTOR (TB) BOARD
3-15. MOTOR (LD) BOARD
Remove the two solderings of motor.
MOTOR (TB) board
table motor assy (M741)
two screws
(BTTP
(BTTP
(M2.6))
wire (flat type) (5 core) (CN742)
stopper
stopper
Remove the two solderings of motor.
MOTOR (LD) board
belt (loading)
loading motor assy (M751)
two screws
(BTTP
(BTTP
(M2.6))
HCD-GT220/GT440/GT660
15
SECTION 4
TEST MODE
COLD RESET
The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning the
set to the customer.
Procedure:
1. Press three buttons of [
RAM to initial conditions. Execute this mode when returning the
set to the customer.
Procedure:
1. Press three buttons of [
x
], [
u
] and [GROOVE] simultane-
ously.
2. The message “COLD RESET” is displayed on the fl uorescent
indicator tube momentarily, then becomes standby states.
TUNING STEP CHANGE-OVER
A step of AM tuning interval can be changed over between 9 kHz
and 10 kHz.
Procedure:
1. Press the [
and 10 kHz.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [TUNER/BAND] button to select “AM”.
3. Press the [
3. Press the [
?/1
] button to turn the power off.
4. Press two buttons of [TUNING +] and [
?/1
] simultaneously.
5. The message “AM 9K STEP” or “AM 10K STEP” is displayed
on the fl uorescent indicator tube, and thus the tuning interval is
changed over.
changed over.
CD SHIP (LOCK) MODE
This mode moves the optical pick-up to the position durable to
vibration. Use this mode when returning the set to the customer
after repair.
Procedure:
1. Press the [
vibration. Use this mode when returning the set to the customer
after repair.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [CD] button to select “CD”.
3. Press two buttons of [
3. Press two buttons of [
u
] and [
?/1
] simultaneously.
4. The message “LOCK” is displayed on the fl uorescent indicator
tube, and the CD ship mode is set.
CD SHIP (LOCK) MODE & COLD RESET
This mode is used to perform CD ship (lock) mode and cold reset
simultaneously.
Procedure:
1. Press the [
simultaneously.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [CD] button to select “CD”.
3. Press three buttons of [
3. Press three buttons of [
x
], [ILLUMINATION] and [
?/1
] si-
multaneously.
4. The message “COLD RESET” is displayed on the fl uorescent
indicator tube momentarily, then becomes standby states.
ANTITHEFT LOCK MODE
This mode is used to unable to take sample disc out of disc table
in the shop.
Procedure:
1. Press the [
in the shop.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [CD] button to select “CD”.
3. Insert a disc.
4. Press two buttons of [
3. Insert a disc.
4. Press two buttons of [
x
] and [
Z
] for 5 seconds.
5. The message “LOCKED” is displayed on the fl uorescent in-
dicator tube and the disc table is locked. (Even if pressing the
[
[
Z
] button, the message “LOCKED” is displayed on the fl uo-
rescent indicator tube and the disc table is locked)
6. To release this mode, press two buttons of [
x
] and [
Z
] for 5
seconds.
7. The message “UNLOCKED” is displayed on the fl uorescent
indicator tube and the disc table is unlocked.
AMP TEST MODE
This mode is used to display the parameter of amplifi er IC and
display the VACS status.
Procedure:
1. Press the [
display the VACS status.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press three buttons of [
x
], [
u
] and [USB] simultaneously.
3. When the AMP test mode is activated, the message “AMP
TEST IN” is displayed on the fl uorescent indicator tube mo-
mentarily, then amplifi er adjustment mode is displayed on the
fl uorescent indicator tube.
mentarily, then amplifi er adjustment mode is displayed on the
fl uorescent indicator tube.
4. Press the [TAPE REC PAUSE/START] button to changed over
between VACS status display mode and the amplifi er IC pa-
rameter display mode.
rameter display mode.
5. In this mode, press the [GROOVE] button to changed over
DBFB on/off, and “DBFB ON” or “DBFB OFF” is displayed
on the fl uorescent indicator tube.
on the fl uorescent indicator tube.
6. In this mode, press the [SURROUND] button to changed over
surround on/off, and “SURROUND ON” or “SURROUND
OFF” is displayed on the fl uorescent indicator tube.
OFF” is displayed on the fl uorescent indicator tube.
− For GT220/GT440 −
7. In this mode, press the [EQ BAND] button to enter the equal-
7. In this mode, press the [EQ BAND] button to enter the equal-
izer adjustment mode.
In the equalizer adjustment mode, press the [EQ BAND] but-
ton to change over the adjustment band as LOW/MID/HIGH.
And turn the [OPERATION DIAL] knob to adjust the equal-
izer level of each bands.
ton to change over the adjustment band as LOW/MID/HIGH.
And turn the [OPERATION DIAL] knob to adjust the equal-
izer level of each bands.
− For GT660 −
7. In this mode, press the [BASS], [VOCAL] or [GUITAR] but-
7. In this mode, press the [BASS], [VOCAL] or [GUITAR] but-
ton to enter the parametric equalizer adjustment mode.
In the parametric equalizer adjustment mode, press the [BASS],
[VOCAL] and [GUITAR] button to change over the adjust-
ment band. And press the [BASS], [VOCAL] or [GUITAR]
button to change over the equalizer frequency of each bands,
or press the [+] and [
[VOCAL] and [GUITAR] button to change over the adjust-
ment band. And press the [BASS], [VOCAL] or [GUITAR]
button to change over the equalizer frequency of each bands,
or press the [+] and [
−] buttons to adjust the equalizer level of
each bands.
8. To release the amplifi er IC parameter display mode or equal-
izer adjustment mode, press the [
?/1
] button to the power off.
MC TEST MODE
This mode is used to check operations of microprocessor.
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press three buttons of [
x
], [
u
] and [AUDIO] simultaneous-
ly.
3. When the MC test mode is activated, VACS level is displayed
on the fl uorescent indicator tube momentarily.
4. Press the [TUNING +] button, the message “ALL EQ MAX”
is displayed on the fl uorescent indicator tube momentarily and
press the [TUNING
press the [TUNING
−] button, the message “ALL EQ MIN” is
displayed on the fl uorescent indicator tube momentarily.
5. Press the [ENTER] button, the message “ALL EQ FLAT” is
displayed on the fl uorescent indicator tube momentarily.
6. Turn the [VOLUME] knob clockwise, the message “VOL-
UME MAX” is displayed on the fl uorescent indicator tube
momentarily and turn the [VOLUME] knob counterclockwise,
the message “VOLUME MIN” is displayed on the fl uorescent
indicator tube momentarily.
momentarily and turn the [VOLUME] knob counterclockwise,
the message “VOLUME MIN” is displayed on the fl uorescent
indicator tube momentarily.
7. Press the [TAPE REC PAUSE/START] button to changed over
VACS on/off.
8. Press the [
?/1
] button to release from this mode, then cold
reset is performed.
HCD-GT220/GT440/GT660
16
VERSION DISPLAY MODE
This mode is used to check the model, destination and software
version.
Procedure:
1. Press the [
version.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press three buttons of [
x
], [
u
] and [ILLUMINATION] si-
multaneously.
3. When this mode is activated, model type and destination (*1)
are displayed on the fl uorescent indicator tube.
*1) GT220, GT440 or GT660
Example: GT660 ASIA2
4. Press the [TAPE REC PAUSE/START] button to display the
Example: GT660 ASIA2
4. Press the [TAPE REC PAUSE/START] button to display the
software version (*2) and year, month, day of the software cre-
ation.
ation.
*2) G**.*** : The version of system controller (IC901 on the
MAIN board).
M**.*** : The version of USB control module in the sysytem
controller.
U**.*** : The version of USB controller (IC901 on the USB
board).
5. To release this mode, press three buttons of [
x
], [
u
] and
[ILLUMINATIOM]
simultaneously.
CD ERROR CODE DISPLAY MODE
This mode can be used for error code display of CD section.
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [CD] button to select “CD”.
3. Press three buttons of [
3. Press three buttons of [
x
], [CD] and [SURROUND] simulta-
neously.
4. When this mode is activated, mechanism deck error code is
displayed on the fl uorescent indicator tube.
5. Press the [ENTER] button to changed over between optical
pick-up error code display mode and mechanism deck error
code mode.
code mode.
Note: There are two [ENTER] buttons on the HCD-GT660, but it works in
the same way whichever button is pressed.
6. Press the [TUNING +]/[TUNING
−] button to change over
display of error history number.
7. To release this mode, press the [
?/1
] button to turn the power
off.
1. Mechanism Deck Error Code Mode
When this mode is entered, mechanism deck error code is displayed
with the 10-character format on the fl uorescent indicator tube.
When this mode is entered, mechanism deck error code is displayed
with the 10-character format on the fl uorescent indicator tube.
The fi rst digit from the left indicates:
The fi rst digit from the left indicates which mode the error history
is. In the mechanism deck error code mode, “M” is displayed on
the fl uorescent indicator tube.
The fi rst digit from the left indicates which mode the error history
is. In the mechanism deck error code mode, “M” is displayed on
the fl uorescent indicator tube.
The second digit from the left indicates:
(Error history number display)
The second digit from the left indicates which order the error his-
tory is. “0” indicates the latest error history, and each time the
number increases by one, the error history goes back to one-previ-
ous error.
(Error history number display)
The second digit from the left indicates which order the error his-
tory is. “0” indicates the latest error history, and each time the
number increases by one, the error history goes back to one-previ-
ous error.
The third and 4th digit from the left indicates:
(Error status display)
The third and 4th digit from the left indicates which error status is
indicated.
(Error status display)
The third and 4th digit from the left indicates which error status is
indicated.
Display
Status
0
0
No error
0
8
Table operation time-out (Table does not move to
the target position within the specifi ed time)
the target position within the specifi ed time)
1
6
In the chucking down operation, the operation was
retried by the maximum number of times but the
operation could not be completed
retried by the maximum number of times but the
operation could not be completed
1
7
In the chucking up and down operation, the reverse
recovery processing was attempted but it could not
be recovered
recovery processing was attempted but it could not
be recovered
1
8
In the chucking up operation, the operation was
retried by the maximum number of times but the
operation could not be completed
retried by the maximum number of times but the
operation could not be completed
2
0
Loading operation time-out (Table does not move to
the target position within the specifi ed time)
the target position within the specifi ed time)
2
2
As the chuck was in the ex-open status at the initial-
ization, the closing was attempted but could not be
completed
ization, the closing was attempted but could not be
completed
The 5th and 6th digit from the left indicates:
(Present status display)
The 5th and 6th digit from the left indicates which operating status
when an error occurred is indicated.
(Present status display)
The 5th and 6th digit from the left indicates which operating status
when an error occurred is indicated.
Display
Status
0
1
Open completion status
0
2
From open status, the movement to chucking down
position is under way
position is under way
0
3
From chucking down position, the open operation is
under way
under way
0
4
Chucking down completion status
1
0
The chucking down operation is under way
1
1
The chucking up operation is under way
1
2
Close completion status
1
3
From close status, the ex-open operation is under
way
way
1
4
From ex-open status, the close operation is under
way
way
1
8
Ex-open completion status
The 7th and 8th digit from the left indicates:
(Motor status display)
The 7th and 8th digit from the left indicates which motor output
status when an error occurred is indicated.
(Motor status display)
The 7th and 8th digit from the left indicates which motor output
status when an error occurred is indicated.
Display
Status
×
0
No table motor output
×
1
Table motor forward output
×
2
Table motor backward output
×
3
Table motor break output
0
×
No loading motor output
1
×
Loading motor forward output
2
×
Loading motor backward output
3
×
Loading motor break output