Sony HCD-GT111 / HCD-GT222 / HCD-GT444 / HCD-GT555 / MHC-GT111 / MHC-GT111BP / MHC-GT222 / MHC-GT444 / MHC-GT555 Service Manual ▷ View online
HCD-GT111/GT222/GT444/GT555
13
3-8. CD MECHANISM BLOCK
3-9. DC FAN (M101), POWERAMP BOARD
Note:
When installing the CD mechanism section,
install two tapes for prevention of noise.
screw
(BVTP3
× 10)
screw
(BVTP3
× 10)
two screws
(BVTP3
× 10)
screw
(BVTP3
× 10)
four screws
(BVTP3
× 10)
two saranet cushions
RT CD mechanism block
RB three sheets
wire (flat type) (31 core)
(MAIN board: CN430/CD board: CN201)
chassis
wire (flat type) (13 core)
(MOTOR board/MAIN board: CN410)
two screws
(BVTP3
× 10)
two screws
(transistor)
RB three screws
(BVTP3
× 10)
connector (CN903)
RT POWERAMP board
screw
(BVTP3
× 10)
two screws
(BVTP3
× 10)
two screws
(BVTP3
× 12)
two screws
(BVTP3
× 10)
bracket (fan)
DC fan (M101)
(GT222/GT444/GT555)
(GT111)
heat sink block
HCD-GT111/GT222/GT444/GT555
14
3-10. BASE UNIT
CD mechanism block
insulator
insulator
base unit
insulator
insulator
two springs
(insulator)
(insulator)
two screws (PTPWHM2.6)
two screws (PTPWHM2.6)
– Bottom view –
two springs (insulator)
Remove four solders.
flexible flat cable (16 core)
(CD board: CN301/optical pick-up block)
CD board
OP base assy
(KSM-213D)
(KSM-213D)
3-11. OP BASE ASSY (KSM-213D)
HCD-GT111/GT222/GT444/GT555
15
four screws
cover
two belts (DLM3A)
belt
belt
position of belt
3-12. BELT (DLM3A)
HCD-GT111/GT222/GT444/GT555
16
SECTION 4
TEST MODE
PANEL TEST MODE
This mode is used to check the fl uorescent indicator tube, LEDs,
keys, [MASTER VOLUME] jog, [OPERATION DIAL] jog, mod-
el, destination and software version.
Procedure:
1. Press
keys, [MASTER VOLUME] jog, [OPERATION DIAL] jog, mod-
el, destination and software version.
Procedure:
1. Press
[
x
] button, [METER MODE] button and [DISC 2] but-
ton simultaneously.
2. All LEDs and segments in fl uorescent indicator tube are lighted
up. The POWER LED is lighted up in red color if the system is
turned off and POWER LED is turn off if the system is turned
on.
turned off and POWER LED is turn off if the system is turned
on.
3. When you want to enter to the software version display mode,
press [DISC 1] button. The model information appears on
the fl uorescent indicator tube. “GSL 1R” is shown for HCD-
GT111, “GSL 2R” is shown for HCD-GT222, “GSL 2RS” is
shown for HCD-GT444 and “GSL 3RS” is shown for HCD-
GT555. Press [DISC 1] button again to view the destination
information.
the fl uorescent indicator tube. “GSL 1R” is shown for HCD-
GT111, “GSL 2R” is shown for HCD-GT222, “GSL 2RS” is
shown for HCD-GT444 and “GSL 3RS” is shown for HCD-
GT555. Press [DISC 1] button again to view the destination
information.
4. During the destination information display, press [DISC 1]
button. Each time [DISC 1] button is pressed, the fl uorescent
indicator tube shows the version of each category software in
the following sequence: SC, GC, SYS, CD, CDDM, CDMA,
CDMB, BDA, BDB, ST, TC, TA, TM, MM1, MM2 (USB
Micro computer) , MTR (METER) and return back to model
information display.
indicator tube shows the version of each category software in
the following sequence: SC, GC, SYS, CD, CDDM, CDMA,
CDMB, BDA, BDB, ST, TC, TA, TM, MM1, MM2 (USB
Micro computer) , MTR (METER) and return back to model
information display.
5. When [DISC 3] button is pressed while the version numbers
are being displayed except model and destination, the date
of the software creation appears. When [DISC 3] button is
pressed again, the display returns to the software version dis-
play. When [DISC 1] button is pressed while the date of the
software creation is being displayed, the date of the software
creation is displayed in the same order of software version dis-
play.
of the software creation appears. When [DISC 3] button is
pressed again, the display returns to the software version dis-
play. When [DISC 1] button is pressed while the date of the
software creation is being displayed, the date of the software
creation is displayed in the same order of software version dis-
play.
6. Press [DISC 2] button, the key check mode is activated.
7. In the key check mode, the fl uorescent indicator tube displays
7. In the key check mode, the fl uorescent indicator tube displays
“K 0 J0 V0”.
Each time a button is pressed, “K” value increases. However,
once a button has been pressed, it is no longer taken into ac-
count.
count.
“V” value increases in the manner of 0,1, 2, 3 ... if [MASTER
VOLUME] knob is turned clockwise, or it decreases in the
manner of 0, 9, 8,7 ... if [MASTER VOLUME] knob is turned
counterclockwise.
manner of 0, 9, 8,7 ... if [MASTER VOLUME] knob is turned
counterclockwise.
“J” value increases in the manner of 0,1, 2, 3 ... if [OPERA-
TION DIAL] knob is turned clockwise, or it decreases in the
manner of 0, 9, 8,7 ... if [OPERATION DIAL] knob is turned
counterclockwise.
manner of 0, 9, 8,7 ... if [OPERATION DIAL] knob is turned
counterclockwise.
8. When [DISC SKIP/EX-CHANGE] button is pressed after all
LEDs and segments in fl uorescent indicator tube light up, al-
ternate segments in fl uorescent indicator tube and LEDs would
light up. If you press [DISC SKIP/EX-CHANGE] button
again, another half of alternate segments in fl uorescent indica-
tor tube and LEDs would light up. Pressing [DISC SKIP/EX-
CHANGE] button again would cause all segments in fl uores-
cent indicator tube and LEDs light up.
ternate segments in fl uorescent indicator tube and LEDs would
light up. If you press [DISC SKIP/EX-CHANGE] button
again, another half of alternate segments in fl uorescent indica-
tor tube and LEDs would light up. Pressing [DISC SKIP/EX-
CHANGE] button again would cause all segments in fl uores-
cent indicator tube and LEDs light up.
9. To release from this mode, press three buttons in the same
manner as step 1, or disconnect the power cord.
COMMON TEST MODE
This mode is used to check operations of the respective sections of
Amplifi er and Tape.
Amplifi er and Tape.
To enter Common Test Mode
Procedure:
1. Press
Procedure:
1. Press
[
x
] button, [METER MODE] button and [DISC 3] but-
ton simultaneously.
2. The CD ring indicators fl ash on the fl uorescent indicator tube.
The function is changed to AUDIO and the volume is changed
to VOLUME MIN.
to VOLUME MIN.
Check of Amplifi er
Procedure:
1. Press [EQ BAND] button repeatedly until a message “GEQ
Procedure:
1. Press [EQ BAND] button repeatedly until a message “GEQ
MAX” appears on the fl uorescent indicator tube. GEQ increas-
es to its maximum.
es to its maximum.
2. Press [EQ BAND] button repeatedly until a message “GEQ
MIN” appears on the fl uorescent indicator tube. GEQ decreas-
es to its minimum.
es to its minimum.
3. Press [EQ BAND] button repeatedly until a message “GEQ
FLAT” appears on the fl uorescent indicator tube. GEQ is set to
fl at.
fl at.
4. When the [MASTER VOLUME] knob is turned clockwise
even slightly, the sound volume increases to its maximum and
a message “VOLUME MAX” appears on the fl uorescent indi-
cator tube.
a message “VOLUME MAX” appears on the fl uorescent indi-
cator tube.
5. When the [MASTER VOLUME] knob is turned counterclock-
wise even slightly, the sound volume decreases to its minimum
and a message “VOLUME MIN” appears on the fl uorescent
indicator tube.
and a message “VOLUME MIN” appears on the fl uorescent
indicator tube.
Tape function
When a tape is inserted in deck and recording is started, the func-
tion is changed to AUDIO.
When a tape is inserted in deck and recording is started, the func-
tion is changed to AUDIO.
To release from Common Test mode
Procedure:
1. To release from this mode, press [
Procedure:
1. To release from this mode, press [
?/1
] button.
2. The cold reset is enforced at the same time.
COLD RESET
The cold reset clears all data including preset data stored in the
EEPROM to initial conditions. Execute this mode when returning
the set to the customer.
Procedure:
1. Press
EEPROM to initial conditions. Execute this mode when returning
the set to the customer.
Procedure:
1. Press
[
?/1
] button to turn on the system.
2. Press
[
x
] button, [ENTER] button, and [
?/1
] button simulta-
neously.
3. “COLD RESET” appears on the fl uorescent indicator tube.
After that, the fl uorescent indicator tube becomes blank for a
while, and the system is reset.
while, and the system is reset.
VACS ON/OFF
This mode is used to switch ON and OFF the VACS (Variable At-
tenuation Control System).
Procedure:
1. Press
tenuation Control System).
Procedure:
1. Press
[
?/1
] button to turn on the system.
2. Press
[
x
] button, [DISC 2], and [DISPLAY] button simultane-
ously. The message “VACS OFF” or “VACS ON” appears on
the fl uorescent indicator tube.
the fl uorescent indicator tube.
Click on the first or last page to see other HCD-GT111 / HCD-GT222 / HCD-GT444 / HCD-GT555 / MHC-GT111 / MHC-GT111BP / MHC-GT222 / MHC-GT444 / MHC-GT555 service manuals if exist.