– 17 –
Record Bias Adjustment  (Deck B)
Procedure:
INTRODUCTION
When set to the test mode performed in 
Tape Speed Adjust-
ment
,
 
when the tape is rewound after recording, the “REC memory
mode” which rewinds only the recorded portion and playback is
set.
This “REC memory mode” is convenient for performing this ad-
justment. During recording, the input signal FUNCTION will auto-
matically switch to VIDEO 1.
(After recording, press the  
0  button without stopping will re-
turn to the position where recording was started.)
1. Press  FUNCTION  button to select VIDEO 1. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B, press the  
r REC  button, and then
press the  
·  button to start recording.
3. Mode: Record
5. Confirm playback the signal recorded in step 2 become adjust-
ment level as follows.
If these levels do not adjustment level, adjust the RV341 (L-CH)
and RV441 (R-CH) on the AUDIO board to repeat steps 3 and 4.
Adjustment level: The playback output of 10 kHz level difference
against 315 Hz reference should be ± 1.0 dB.
Adjustment Location: AUDIO board
Record Level Adjustment  (Deck B)
Procedure:
INTRODUCTION
When set to the test mode performed in 
Tape Speed Adjust-
ment
, when the tape is rewound after recording, the “REC memory
mode” which rewinds only the recorded portion and playback is
set.
This “REC memory mode” is convenient for performing this
adjustment. During recording, the input signal FUNCTION will au-
tomatically switch to VIDEO 1.
(After recording, press the  
0  button without stopping will re-
turn to the position where recording was started.)
1. Press  FUNCTION  button to select VIDEO 1. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B, press the  
r REC  button, and then
press the  
·  button to start recording.
3. Mode: Record
4. Mode: Playback
5. Confirm playback the signal recorded in step 2 become adjust-
ment level as follows.
If these levels do not adjustment level, adjust the RV301 (L-CH)
and RV351 (R-CH) on the MAIN board to repeat steps 3 and 4.
Adjustment level:
CN403 playback level: 47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location: MAIN board
Adjustment Location:
[AUDIO BOARD] (Conductor Side)
4. Mode: Playback
[MAIN BOARD] (Conductor Side)
recorded
position
level meter
set
MD OUT
AF OSC
VIDEO 1 (AUDIO) IN
1) 315 Hz
2) 10 kHz
blank tape
CS-123
set
attenuator
600 
} 50 mV (–23.8 dB)
AF OSC
VIDEO 1 (AUDIO) IN
315Hz 50 mV (–23.8 dB)
blank tape
CS-123
set
attenuator
600 
recorded
position
level meter
set
MD OUT
Record Level (Lch)
RV301
RV351
Record Level (Rch)
IC301 56
43 42
29
28
15
14
1
1
3
RV441 RV341
RV301(Lch),RV401(Rch)
Playback Level (Deck B)
RV301 RV401
RV341(Lch),RV441(Rch)
Record Bias
RV311(Lch),RV411(Rch)
Playback Level (Deck A)
RV311
RV411
– 18 –
CD SECTION
Note:
1. CD Block is basically constructed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the fol-
lowing checks.
S Curve Check
Procedure :
1. Connect the oscilloscope to test points TP (FE) and TP (VC).
2. Connect TP (FEI) and GND, and TP (AGCCON) and GND of
the BD board with lead wires.
3. Press the  
1/u  button to turn the set ON.
4. With the disc (YEDS-18) loaded, press the  
·P  button and
perform focus search. (Focus search will be performed in the
same way even while the disc table is pushed in and out.)
5. Check the symmetry and peak to peak level of the oscilloscope
waveform (S curve) at this time.
S-curve waveform
6. After check, remove the lead wire connected in step 2.
Note:
 • Try to measure several times to make sure than the ratio of
A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the bright-
ness to obtain best waveform.
RF Level Check
Procedure :
1. Connect oscilloscope to test point TP (RF) and TP (VC) on BD
board.
2. Connect TP (AGCCON) and GND of the BD board with lead
wires.
3. Press the  
1/u  button to turn the set ON.
4. Put disc (YEDS-18) in and playback 5 track.
5. Confirm that oscilloscope waveform is clear and check RF sig-
nal level is correct or not.
6. After check, remove the lead wire connected in step 2.
Adjustment Location :
[ BD BOARD ] — SIDE A —
Procedure:
1. Connect oscilloscope to test point TP (TE) on BD board.
2. Press the  
1/u  button to turn the unit ON.
3. Put disc (YEDS-18) in to play the number five track.
4. Press the  
·P button.
5. Check the level B of the oscilloscope's waveform and the A (DC
voltage) of the center of the Traverse waveform.
Confirm the following:
• A/B x 100 = less then ± 22 (%)
• B = 1.3 ± 0.6 Vp-p
1 track jump waveform
E-F Balance (1 Track Jump) check
oscilloscope
BD board
TP (FE)
TP (VC)
+
symmetry
A
B
Within 4 
±
 1 Vp-p
oscilloscope
BD board
TP (RF)
TP (VC)
+
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.45 
±
 0.25 Vp-p
0V
Center of the waveform
B
Symmetry
A (DC voitage)
level : 1.3 
±
 0.6 Vp-p
oscilloscope
BD board
TP (TE)
TP (VC)
+
TP
(VC)
TP
(RF)
TP
(TE)
TP
(FE1)
TP (FE)
TP
(AGCCON)
Note:
Clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
HCD-DR7AV/XB800AV
– 19 –
SECTION  7
DIAGRAMS
7-1. CIRCUIT BOARDS LOCATION
TUNER UNIT
SURROUND AMP board
JACK board
TC-B board
TC-A board
PANEL FL board
PANEL VR board
FRONT INPUT board
TRANS board
SUB TRANS board
(XB800AV)
MAIN board
PA board
CD-L board
CD-R board
LED (PANEL) board
DOOR SWITCH board
BD board
LED (CD) board
CD MOTOR board
TABLE SENSOR board
AUDIO board
LEAF SW board
HCD-DR7AV/XB800AV
7-2. BLOCK DIAGRAMS
– BD (CD) SECTION –
– 21 –
– 22 –
E
F
A
B
C
D
A
C
RF
FF
TE
D
B
E
F
LD
PD
VCC
VC
RF
SUMMING
AMP
FOCUS
ERROR
AMP
TRACKING
ERROR
AMP
LD
DRIVE
Q101
VC
BUFFER
INTEG-
RATOR
RF EQ
AMP
INTEG-
RATOR
DIGITAL
PLL
IC101
DIGITAL SERVO
DIGITAL SIGNAL PROCESSOR
SUBCODE
PROCESSOR
SERIAL IN
INTERFACE
SERVO
AUTO
SEQUENCER
SERVO
INTERFACE
OVER SAMPLING
DIGITAL FILTER
D/A
INTERFACE
DIGITAL
OUT
TIMING
LOGIC
ERROR
CORRECTOR
EFM
DEMODULATION
APCLD/PD
AMP
5
7
8
6
16
14
49
51
13
LDON
VC
22
15
21
12
11
10
3
IC103
RF AMP
VC
4
VREF
HOLD SW
REF
IC102
FOCUS/TRACKING COIL DRIVE
SPINDLE/SLED MOTOR DRIVE
11
12
T+
T–
14
13
F+
F–
TRACKING
COIL
FOCUS
COIL
CH2OUTR
CH2OUTF
5
CH2FIN
6
CH2RIN
2
CH1FIN
3
CH1RIN
23
CH3RIN
24
CH3FIN
25
CH4SIN
27
CH4BIN
20
MUTE
CH1OUTF
CH1OUTR
17
18
SD+
SD–
CH3OUTF
CH3OUTR
M
15
16
SP+
SP–
CH4OUTF
CH4OUTR
M
M102
SLED
MOTOR
M101
SPINDLE
MOTOR
TFDR
TRDR
FFDR
FRDR
SRDR
SFDR
VC
FD
PD
LASER
DIODE
A
C
D
B
E
F
DETECTOR
OPTICAL PICK-UP BLOCK
(KSS-213B/K-N)
LD
POWER
RF AC
ASY1
48
38
42
43
39
41
40
28
26
29
ASY0
ASYMMETRY
CORRECTION
SFDR
MDP
SRDR
33
32
FRDR
FFDR
31
30
42
TRDR
TFDR
SE
CE
TE
FE
RFDC
CE
VC
SLED
PWM
GENERATOR
FOCUS
PWM
GENERATOR
TRACKING
PWM
GENERATOR
PWM
GENERATOR
SLED
SERVO
FOCUS
SERVO
TRACKING
SERVO
SERVO DSP
DIGITAL
CLV
OPERATIONAL
AMPLIFIER
ANALOG
SWITCH
A/D
CONVERTER
16K
RAM
DATA BUS
3rd ORDER
NOISE SHAPER
PWM
PWM
CPU
INTERFACE
2
1
3
SQSO
60
D OUT
67
STAO
66
XTA1
8
SENS
20
SCOR
14
XLON
XRST
SQCK
5
DATA
6
XLAT
7
CLOK
9
SCLK
27
SSTP
79
RMUT
80
LMUT
70
LMUT
71
AIN1
72
LOUT1
77
LOUT2
76
AIN2
75
LOUT2
L OUT
R OUT
HOLD
+5V
SQCK
SCOR
CLOK
XLT
DATA
SENS
SQSO
XRST
DOUT
X101
16.9344MHz
A
MAIN
SECTION
(Page 25, 27)
09
S101
LIMIT SW
• SIGNAL PATH
            : CD
            : Digital out
Page of 90
Display

Click on the first or last page to see other HCD-DR7AV / HCD-XB800AV / LBT-DR7AVS service manuals if exist.