Sony HCD-DJ2I / LBT-DJ2I Service Manual ▷ View online
HCD-DJ2i
21
SECTION 4
TEST MODE
GC TEST MODE
• This mode is used to check the fl uorescent indicator tube,
• This mode is used to check the fl uorescent indicator tube,
LEDs, keys, VOLUME knob, OPERATION DIAL knob,
model, destination and software version.
model, destination and software version.
Procedure:
1. Press
1. Press
[
s] button, [BEAT PATTERN] button and
[MENU/RETURN] on CHANNEL A button simultaneously.
2. All LEDs and segments in fl uorescent indicator tube are
lighted up. All LEDs are lighted up including [
] LED
where the LED is lighted up in red and blue color.
3. When you want to enter to the model version and destination
display mode, press [BEAT ON/OFF] button. The model
information appears on the fl uorescent indicator tube.
information appears on the fl uorescent indicator tube.
4. Each time [BEAT ON/OFF] button is pressed, the display
changes to display software version and date of the software
creation. The sequence is SC, GC, SYS, CD, CDDM, CDMA,
CDMB, BDA, BDB, ST, TC, TA, TM, MM1, MM2, IP1 and
IP2 in this order, and returns to the model version display.
creation. The sequence is SC, GC, SYS, CD, CDDM, CDMA,
CDMB, BDA, BDB, ST, TC, TA, TM, MM1, MM2, IP1 and
IP2 in this order, and returns to the model version display.
5. Press [BEAT PATTERN] button, the key check mode is
activated.
6. In the key check mode, the fl uorescent indicator tube
displays.
activated.
6. In the key check mode, the fl uorescent indicator tube
displays.
J0 K 0 J0
L0M0H0 V0
Turn the [MULTI JOG DIAL A] clockwise; ”J” value on the
left increases by one. Turn the [MULTI JOG DIAL A]
counterclockwise; “J” value on the left decreases by one.
Turn the [MULTI JOG DIAL B] clockwise; ”J” value on
the right increases by one. Turn the [MULTI JOG DIAL B]
counterclockwise; “J” value on the right decreases by one.
Each time a button is pressed, “K” value increases. Press
other keys on main unit to check whether the key is detected.
However, once a button has been pressed, it is no longer
taken into account.
“V” value increases in the manner of 0, 1, 2, 3 ... if
[VOLUME] knob is turned clockwise, or it decreases in the
manner of 0, 9, 8, 7 ... if [VOLUME] knob is turned
counterclockwise.
“L” value increases in the manner of 0, 1, 2, 3 ... if [LOW]
knob is turned clockwise, or it decreases in the manner of 0,
9, 8, 7 ... if [LOW] knob is turned counterclockwise.
“M” value increases in the manner of 0, 1, 2, 3 ... if [MID]
knob is turned clockwise, or it decreases in the manner of 0,
9, 8, 7 ... if [MID] knob is turned counterclockwise.
“H” value increases in the manner of 0, 1, 2, 3 ... if [HIGH]
knob is turned clockwise, or it decreases in the manner of 0,
9, 8, 7 ... if [HIGH] knob is turned counterclockwise.
left increases by one. Turn the [MULTI JOG DIAL A]
counterclockwise; “J” value on the left decreases by one.
Turn the [MULTI JOG DIAL B] clockwise; ”J” value on
the right increases by one. Turn the [MULTI JOG DIAL B]
counterclockwise; “J” value on the right decreases by one.
Each time a button is pressed, “K” value increases. Press
other keys on main unit to check whether the key is detected.
However, once a button has been pressed, it is no longer
taken into account.
“V” value increases in the manner of 0, 1, 2, 3 ... if
[VOLUME] knob is turned clockwise, or it decreases in the
manner of 0, 9, 8, 7 ... if [VOLUME] knob is turned
counterclockwise.
“L” value increases in the manner of 0, 1, 2, 3 ... if [LOW]
knob is turned clockwise, or it decreases in the manner of 0,
9, 8, 7 ... if [LOW] knob is turned counterclockwise.
“M” value increases in the manner of 0, 1, 2, 3 ... if [MID]
knob is turned clockwise, or it decreases in the manner of 0,
9, 8, 7 ... if [MID] knob is turned counterclockwise.
“H” value increases in the manner of 0, 1, 2, 3 ... if [HIGH]
knob is turned clockwise, or it decreases in the manner of 0,
9, 8, 7 ... if [HIGH] knob is turned counterclockwise.
7. When [BEAT LEVEL] button is pressed after all LEDs and
segments in fl uorescent indicator tube light up, alternate
segments in fl uorescent indicator tube and LED would light
up. If you press [BEAT LEVEL] button again, another half
of alternate segments in fl uorescent indicator tube and LED
would light up. Press [BEAT LEVEL] button would cause
all segments in fl uorescent indicator tube and LED turns off.
Press [BEAT LEVEL] button again would cause all segments
and LED lights up.
segments in fl uorescent indicator tube and LED would light
up. If you press [BEAT LEVEL] button again, another half
of alternate segments in fl uorescent indicator tube and LED
would light up. Press [BEAT LEVEL] button would cause
all segments in fl uorescent indicator tube and LED turns off.
Press [BEAT LEVEL] button again would cause all segments
and LED lights up.
8. To release from this mode, press three buttons in the same
manner as step 1, or disconnect the power cord.
MC TEST MODE
• This mode is used to check operations of the respective
• This mode is used to check operations of the respective
sections of Amplifi er, Cross Fader Slider, and
i Level.
Procedure:
• To enter MC Test Mode
1. Press
• To enter MC Test Mode
1. Press
[
s] button, [BEAT LEVEL] button and
[MENU/RETURN] on CHANNEL A button simultaneously.
2. The Groove, Surround, Booster, Beat Level indicators fl ash
on the fl uorescent indicator tube. The function is changed to
LINE IN 2.
LINE IN 2.
• Check of Amplifi er
1. Turn [LOW] knob/[MID] knob/[HIGH] knob repeatedly until
1. Turn [LOW] knob/[MID] knob/[HIGH] knob repeatedly until
a message “GEQ MAX” appears on the fl uorescent indicator
tube. GEQ increases to its maximum.
tube. GEQ increases to its maximum.
2. Turn [LOW] knob/[MID] knob/[HIGH] knob repeatedly until
a message “GEQ MIN” appears on the fl uorescent indicator
tube. GEQ decreases to its minimum.
tube. GEQ decreases to its minimum.
3. Turn [LOW] knob/[MID] knob/[HIGH] knob repeatedly until
a message “GEQ FLAT” appears on the fl uorescent indicator
tube. GEQ is set to fl at.
tube. GEQ is set to fl at.
4. When the [VOLUME] knob is turned clockwise even slightly,
the sound volume increases to its maximum and a message
“VOLUME MAX” appears on the fl uorescent indicator tube.
“VOLUME MAX” appears on the fl uorescent indicator tube.
5. When the [VOLUME] knob is turned counterclockwise even
slightly, the sound volume decreases to its minimum and a
message “VOLUME MIN” appears on the fl uorescent
message “VOLUME MIN” appears on the fl uorescent
indicator
tube.
• Check of Cross Fader Slider
1. Slide the [CROSS FADER] slider from one position to
1. Slide the [CROSS FADER] slider from one position to
another. “LVL 0” appears when the slider is on the right
position and “LVL12” appears when the slider is on the left
position.
position and “LVL12” appears when the slider is on the left
position.
• Check of
i Level
1. Turn the [
i LEVEL] knob clockwise or counterclockwise.
“LVL 0” appears when the knob is on the MIN position and
“LVL15” appears when the knob is on the MAX position.
“LVL15” appears when the knob is on the MAX position.
• To release from MC Test mode
1. To release from this mode, press [
1. To release from this mode, press [
?/1] button.
2. The cold reset is enforced at the same time.
COLD RESET
• The cold reset clears all data including preset data stored in the
• The cold reset clears all data including preset data stored in the
RAM to initial conditions.
• Execute this mode when returning the set to the customer.
• Procedure:
1. Press
[
s] button, [PAD I] button, and [?/1] button
simultaneously.
2. The
fl uorescent indicator tube becomes blank for a while,
and the set is reset.
VACS ON/OFF
• This mode is used to switch ON and OFF the VACS (Variable
• This mode is used to switch ON and OFF the VACS (Variable
Attenuation Control System).
• Procedure:
1. Press
[
?/1] button to turn the set ON.
2. Press
[
s] button and [OPTIONS] button simultaneously.
The message “VACS OFF” or “VACS ON” appears on
the fl uorescent indicator tube.
the fl uorescent indicator tube.
HCD-DJ2i
22
TUNER STEP CHANGE
• The step interval of AM channels can be toggled between 9
• The step interval of AM channels can be toggled between 9
kHz and 10 kHz. This mode is not available for Saudi Arabia
model.
model.
• Procedure:
1. Press
[
?/1] button to turn the set ON.
2. Press [TUNER/BAND] button to select the “AM”.
3. Press
3. Press
[
?/1] button to turn the set OFF.
4. Press [ENTER] on CHANNEL B button and [
?/1]
button simultaneously. The system will turn ON
automatically. The message “AM 9K STEP” or “AM 10K
STEP” appears on the fl uorescent indicator tube and thus
the channel step is changed.
STEP” appears on the fl uorescent indicator tube and thus
the channel step is changed.
CD SERVICE MODE
• This mode let you move the CD sled motor freely. Use this
• This mode let you move the CD sled motor freely. Use this
mode when you want to clean the optical pick-up.
• Procedure:
1. Press
[
?/1] button to turn the set ON.
2. Select CD function.
3. Press [CD] button, [
3. Press [CD] button, [
L] on CHANNEL A button, and
[BEAT PATTERN] button simultaneously.
4. The CD service mode is activated. The message
“SERVICE MODE” appears on the fl uorescent indicator
tube.
tube.
5. With the CD in stop status, press [
+] button to move
the optical pick-up to outside track, or press [
–] button
to move to inside track. The message “SLED OUT” or
“SLED IN” appears on the fl uorescent indicator tube.
“SLED IN” appears on the fl uorescent indicator tube.
6. To turn on or off the laser, press [
L TUNE +] on
CHANNEL B button. The message “LD ON” or “LD
OFF” appears on the fl uorescent indicator tube.
OFF” appears on the fl uorescent indicator tube.
7. To release from this mode, press [
?/1] button.
CD AGING MODE
• This mode can be used for operation check of CD section.
• This mode can be used for operation check of CD section.
If an error occurs, the aging operation would stops and the
status is displayed.
If there were no error occurs, the aging operation would
continue repeatedly.
status is displayed.
If there were no error occurs, the aging operation would
continue repeatedly.
• Procedure:
1. Press
[
?/1] button to turn the set ON.
2. Select CD function.
3. Load a disc on the disc tray.
4. Press [PLAY MODE/TUNING MODE] button on the
3. Load a disc on the disc tray.
4. Press [PLAY MODE/TUNING MODE] button on the
remote commander repeatedly to select the Normal Play
mode, and press the [REPEAT/FM MODE] button on the
remote commander repeatedly to select repeat mode off.
mode, and press the [REPEAT/FM MODE] button on the
remote commander repeatedly to select repeat mode off.
5. Press [CD] button, [BEAT PATTERN] button and
[
i SELECT] button simultaneously.
6. Aging operation is started.
7. To release from this mode, press [
7. To release from this mode, press [
?/1] button or
disconnect the power cord to turn the power OFF.
• Aging mode sequence:
START
Disc Chucking
TOC Reading
Play first track for
2 seconds
Play last track for
2 seconds
Open the disc tray
Close the disc tray
HCD-DJ2i
23
CD ERROR CODE MODE
1. Display the CD error code when an error occurred.
1. Display the CD error code when an error occurred.
2. Procedure:
1. Press [CD] button, [BEAT PATTERN] button and [
l]
on CHANNEL A button simultaneously to enter the error
code display mode.
code display mode.
2. The
fl uorescent indicator tube displays the number of
total error.
3. Each time [
+] button or [
–] button is pressed,
display change as below.
Display of
Total Error
Total Error
Display of
Mechanical
Errors
MTUNE –
(CHANNEL B)
button
MTUNE –
(CHANNEL B)
button
-TUNE +
(CHANNEL B)
button
-TUNE +
(CHANNEL B)
button
+ button
– button
Display of
No Disc
Errors
+ button
– button
4. To clear the error record, operate the cold reset. (Refer to
the “MC COLD RESET”)
5. To release from this mode, press the [
?/1] button or
disconnect the power plug to turn the power OFF.
3. Display of total error
Em**Ed**
Em**: The number of times for CDM (mechanical) errors.
Ed**: The number of times for BD error (after chucking the disc).
Ed**: The number of times for BD error (after chucking the disc).
• Display of CDM (mechanical) errors. It is show with “M” and
11 digit number.
M * $$%%&&0 –
000
000
M * : The number of history error for mechanical.
(“0” is latest one)
(Press [L TUNE +] on CHANNEL B button to display next
error)
$$: Mechanical errors occur in the operation
FF: Mechanical error during normal operation
Other: Mechanical error during initializing operation
error)
$$: Mechanical errors occur in the operation
FF: Mechanical error during normal operation
Other: Mechanical error during initializing operation
%%: The process when trouble occurs
01: Process ejecting DISC
02: Process waiting for inserting DISC
03: Process sending request to insert a disc to upper layer
04: Process sending request to eject a disc to upper layer
05: Process pulling a DISC in
06: Chucking process
07: Re-chucking process
08: Process cancelling chucking
02: Process waiting for inserting DISC
03: Process sending request to insert a disc to upper layer
04: Process sending request to eject a disc to upper layer
05: Process pulling a DISC in
06: Chucking process
07: Re-chucking process
08: Process cancelling chucking
&&: The operation when trouble occurs
00: Waiting for operation
10 /11/ 12/13: During eject operation
20: While pulling a disc in
30: While cancelling chucking
30: While cancelling chucking
40/ 41/ 42/ 43: During eject operation due to error
0000: Not used (value is fi xed to 0000)
• Display of BD errors. It is shown with “D” and 11 digits
number.
D*$$%%& -
#00
#00
D *: The number of error history (“0” is latest one)
(Press [
(Press [
L TUNE +] on CHANNEL B button to display
next error)
$$: The detail of trouble
$$: The detail of trouble
01: Can not focus
02: GFS error
03: start-up time over
04: Continuously out of focus
05: Q code is not input for certain time
06: Tracking on is impossible
07: Blank disc
02: GFS error
03: start-up time over
04: Continuously out of focus
05: Q code is not input for certain time
06: Tracking on is impossible
07: Blank disc
%%: The process when trouble occurs
01: While SHIP process is performed
02: While POWER OFF is processed
03: While INITIALIZE (POWER ON) is processed
04: While oscillation stops
05: From stopping oscillation to start oscillation
06: During stop
07: During STOP operation
08: While start-up is processed
09: While TOC reading is processed
0a: During search operation
0b: During PLAY operation
0c: During pause operation
0d: During PLAY manual search operation
0e: During PAUSE manual search operation
02: While POWER OFF is processed
03: While INITIALIZE (POWER ON) is processed
04: While oscillation stops
05: From stopping oscillation to start oscillation
06: During stop
07: During STOP operation
08: While start-up is processed
09: While TOC reading is processed
0a: During search operation
0b: During PLAY operation
0c: During pause operation
0d: During PLAY manual search operation
0e: During PAUSE manual search operation
&&: Processing operation when trouble occurs. Show each
STEP mentioned in %% digits
##: Disc sped when trouble occurs
01: x1 speed
02: x2 speed (for models which support x2 speed)
04: x4 speed
00: Not used (value is fi xed to 00)
02: x2 speed (for models which support x2 speed)
04: x4 speed
00: Not used (value is fi xed to 00)
HCD-DJ2i
24
CD REPEAT 5 LIMIT OFF MODE
• The number of repeat for CD playback is 5 times when the
• The number of repeat for CD playback is 5 times when the
repeat mode is “REPEAT ALL”. This mode enables CD to
repeat playback for limitless times.
repeat playback for limitless times.
• Procedure:
1. Press
[
?/1] button to turn the set ON.
2. Select CD function.
3. Press [CD] button, [BEAT LEVEL] button and
3. Press [CD] button, [BEAT LEVEL] button and
[MENU/RETURN] on CHANNEL A button
simultaneously to enter the CD repeat 5 limit off mode
and the fl uorescent indicator tube displays “LIMIT OFF”.
and the fl uorescent indicator tube displays “LIMIT OFF”.
4. To release from this mode, operate the cold reset. (Refer
to the “MC COLD RESET”)
CD SHIP MODE (WITH MEMORY CLEAR)
• This mode moves the optical pick-up to the position durable
• This mode moves the optical pick-up to the position durable
to vibration and clears all data including preset data stored in
the RAM to initial conditions. Use this mode when returning
the set to the customer after repair.
the RAM to initial conditions. Use this mode when returning
the set to the customer after repair.
• Procedure:
1. Press
[
?/1] button to turn the set ON.
2. Select CD function.
3. Press [CD] button, [BPM CONTROL] button and [
3. Press [CD] button, [BPM CONTROL] button and [
?/1]
button simultaneously. The set will power off
automatically.
4. After the “STANDBY” blinking display fi nishes, a
4. After the “STANDBY” blinking display fi nishes, a
message “MECHA LOCK” is displayed on the
fl uorescent indicator tube and the CD ship mode is set.
5. Then AC power OFF.
CD SHIP MODE (WITHOUT MEMORY CLEAR)
• This mode moves the optical pick-up to the position durable
• This mode moves the optical pick-up to the position durable
to vibration. Use this mode when returning the set to the
customer after repair.
customer after repair.
• Procedure:
1. Press
[
?/1] button to turn the set ON.
2. Select CD function.
3. Press [CD] button and [
3. Press [CD] button and [
?/1] button simultaneously. The
set will power off automatically.
4. After the “STANDBY” blinking display fi nishes, a
message “MECHA LOCK” is displayed on the
fl uorescent indicator tube and the CD ship mode is set.
5. The AC power OFF.
CD TRAY LOCK MODE
• This mode let you lock the disc tray. When this mode is
• This mode let you lock the disc tray. When this mode is
activated, the disc tray will not open when [
A] button is
pressed. The message “LOCKED” will be displayed on the
fl uorescent indicator tube.
fl uorescent indicator tube.
• Procedure:
1. Press
[
?/1] button to turn the set ON.
2. Select CD function.
3. Press
3. Press
[
s] button and [A] button simultaneously and hold
down until “LOCKED” or “UNLOCKED” displayed on
the fl uorescent indicator tube (around 5 seconds).
the fl uorescent indicator tube (around 5 seconds).
VACS DISPLAY
• This mode is used to check the VACS level.
• This mode is used to check the VACS level.
• Procedure:
1. Press
[
?/1] button to turn on the system.
2. Press
[
s] button, [PAD I] button and [OPTIONS] button
simultaneously.
3. The VACS Level Display, the fl uorescent indicator tube
displays “VACS X”. It represents VACS level which is
triggered by signal level.
triggered by signal level.
4. To release from this mode, press [
s] button, [PAD I]
button and [OPTIONS] button simultaneously again.
Click on the first or last page to see other HCD-DJ2I / LBT-DJ2I service manuals if exist.