DOWNLOAD Sony HBD-E385 / HBD-E390 / HBD-T39 Service Manual ↓ Size: 7.68 MB | Pages: 93 in PDF or view online for FREE

Model
HBD-E385 HBD-E390 HBD-T39
Pages
93
Size
7.68 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hbd-e385-hbd-e390-hbd-t39.pdf
Date

Sony HBD-E385 / HBD-E390 / HBD-T39 Service Manual ▷ View online

HBD-E385/E390/T39
17
1 wire (flat type) (7 core)
 (CN5902)
2 wire (flat type)
 
(30 core) (CN5904)
3 CN5301 (11P)
‡:LUHVHWWLQJ front side
AMP board
switching regulator
(SWR1)
5 three screws
 (+BV3 
(3-CR))
4 four screws (+BV3 (3-CR))
7 heat sink (MB)
8 sheet, radiation
9 MB148 board
6 one screw (+B 3 u 5)
2-7.  BD  DRIVE (BPX-7)
2-8.  MB148  BOARD
4 four screws
 (+BV3 
(3-CR))
7 BD drive BPX-7
5 boss
6
1 flexible flat cable (45 core) (CN1101)
3 wire (flat type)
 
(9 core) (CN1260)
2 wire (flat type) (5 core) (CN1270)
Note: When you install the BD 
 
drive (BPX-7), please match 
 
the position of the boss two 
 places.
HBD-E385/E390/T39
18
2-9.  SWITCHING  REGULATOR (SWR1)
2-10.  AMP  BOARD
3 three screws (+BV3 (3-CR))
2 two screws (+BV3 (3-CR))
5 four screws (+BV3 (3-CR))
6 AMP board
4 heat sink (AMP)
1 CN3501 (2P)
1 one screw (+BV3 (3-CR))
6 five screws (+BV3 (3-CR))
7 switching regulator
 (SWR1)
3 CN1 (2P)
4 CN101 (4P)
5 CN4 (2P)
2 insulation, top (S)
‡3RZHUFRUGVHWWLQJ
rear side
switching
regulator
(SWR1)
HBD-E385/E390/T39
19
2-11.  OPTICAL  PICK-UP  BLOCK (KEM480AAA),  WIRE (FLAT  TYPE)
6 two screws (S), float
0 insulator
4 Insert the thin 
 
wire (clip etc.).
0 insulator
qa device, optical
 KEM480AAA
0 insulator
qs tape,
 non-halogene
qj
qk cover, drive
qg flexible flat cable 
 (45 
core)
qh wire (flat type) 
 (9 
core)
1 four claws
5
7
8
9
2 two claws
3 holder, chuck assy (T)
qd wire (flat type)
 (5 
core)
qf tape, FFC
– Bottom view –
loading assy (T)
8
9 cover, drive
1 flexible flat cable (45 core)
6 wire (flat type)
 (5 
core)
Fold
Fold
2 Through the hole
3 wire (flat type) (9 core)
4 Through the hole
terminal face
terminal face
loading assy (T)
Under the guide
(Fold area)
Under the guide
‡,QVWDOODWLRQRIIOH[LEOHIODWFDEOHFRUHZLUHIODWW\SHFRUHDQGZLUHIODWW\SHFRUH
Note: This illustration sees the loading assy (T) from bottom side.
5 tape, FFC
7 tape,
 non-halogene
HBD-E385/E390/T39
20
SECTION  3
TEST  MODE
COLD  RESET
The cold reset clears data except BD/DVD data stored in the RAM 
to initial conditions. Execute this mode when returning the unit to 
the customers.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [
x
] and [VOL –] buttons simultaneously and hold 
down (around 5 seconds).
3.  The message “RESET” appears on fl uorescent indicator tube, 
then becomes standby states.
DEMO  MODE
This mode let you lock the disc tray. When this mode is activated, 
the disc will not eject when the [
Z
] button is pressed. The message 
“DEMO. LOCK” will be displayed on the fluorescent indicator 
tube.
Procedure:
1.  Press the [
?/1
] button to turn the power on. 
2.  Press the [FUNCTION] button to select the “BD/DVD”.
3.  Press the [
x
] and [
Z
] buttons simultaneously and hold down 
until “DEMO. LOCK” or “DEMO OFF” displayed on the 
fluorescent indicator tube (around 5 seconds).
Releasing method:
Press the [
x
] and [
Z
] buttons simultaneously and hold down until 
“DEMO OFF” displayed on the fl uorescent indicator tube (around 
5 seconds).
PANEL TEST
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press button in order of the [DISPLAY] 
[0] [0] [1] 
[SUBTITLE] on the remote commander (Make the interval 
when each button is pressed within two seconds).
3.  All segments in fl uorescent indicator tube are lighted up. And 
half segments in fl uorescent indicator tube are lighted up, oth-
ers half segments in fl uorescent indicator tube are lighted up, 
then all segments in fl uorescent indicator tube are lighted up. 
This operation is repeated.
4.  When all segments in fl uorescent indicator tube are lighted up 
in the state of step 3, press the [VOL +] button on the remote 
commander and model information is displayed on the fl uores-
cent indicator tube.
 
Each time the [VOL +] button on the remote commander is 
pressed, the display changes from destination information, 
STR version in this order, and returns to the model informa-
tion display.
5.  In the state of step 3, press the [FUNCTION] button on the 
remote commander and “K 0” is displayed on the fluorescent 
indicator tube.
 
“K 0” value increases whenever a button or sensor on the unit 
is pressed. However, once a button or sensor has been pressed, 
it is no longed taken into account.
 
All button and sensors on the unit are pressed, “OK” and “K 9” 
are alternately displayed on the fluorescent indicator tube.
Releasing method:
To release from this mode, press the [
?/1
] button.
FACTORY  INITIALIZE
Return all of the unit setting to their factory defaults.
Note 1: Disconnect the following connections when you use this mode.
 
   
 USB
 
   
 LAN
Note 2: The operation in this mode must use a remote commander and TV 
monitor.
Procedure:
1.  Press the [
?/1
] button to turn the power on. 
2.  Press the [HOME] button on the remote commander, and the 
home menu is displayed.
3. Select 
“Setup” 
 “Resetting”, and press the [ ] button on the 
remote commander.
4.  Select “Initialize Personal Information”, and press the [
button on the remote commander.
5.  Select “OK”, and press the [
] button on the remote com-
mander.
Resetting
Easy Setup
Initialize Personal Information
Erase personal data when disposing
Reset to Factory Default Settings
Initialize Personal Information
OK
Cancel
The information below will be deleted.
Do you want to proceed?
- Playback history
- Internet video utilization information
Page of 93
Display

Click on the first or last page to see other HBD-E385 / HBD-E390 / HBD-T39 service manuals if exist.