Sony HBD-E385 / HBD-E390 / HBD-T39 Service Manual ▷ View online
HBD-E385/E390/T39
17
1 wire (flat type) (7 core)
(CN5902)
(CN5902)
2 wire (flat type)
(30 core) (CN5904)
3 CN5301 (11P)
:LUHVHWWLQJ front side
AMP board
switching regulator
(SWR1)
(SWR1)
5 three screws
(+BV3
(+BV3
(3-CR))
4 four screws (+BV3 (3-CR))
7 heat sink (MB)
8 sheet, radiation
9 MB148 board
6 one screw (+B 3 u 5)
2-7. BD DRIVE (BPX-7)
2-8. MB148 BOARD
4 four screws
(+BV3
(+BV3
(3-CR))
7 BD drive BPX-7
5 boss
6
1 flexible flat cable (45 core) (CN1101)
3 wire (flat type)
(9 core) (CN1260)
2 wire (flat type) (5 core) (CN1270)
Note: When you install the BD
drive (BPX-7), please match
the position of the boss two
places.
HBD-E385/E390/T39
18
2-9. SWITCHING REGULATOR (SWR1)
2-10. AMP BOARD
3 three screws (+BV3 (3-CR))
2 two screws (+BV3 (3-CR))
5 four screws (+BV3 (3-CR))
6 AMP board
4 heat sink (AMP)
1 CN3501 (2P)
1 one screw (+BV3 (3-CR))
6 five screws (+BV3 (3-CR))
7 switching regulator
(SWR1)
(SWR1)
3 CN1 (2P)
4 CN101 (4P)
5 CN4 (2P)
2 insulation, top (S)
3RZHUFRUGVHWWLQJ
rear side
switching
regulator
(SWR1)
regulator
(SWR1)
HBD-E385/E390/T39
19
2-11. OPTICAL PICK-UP BLOCK (KEM480AAA), WIRE (FLAT TYPE)
6 two screws (S), float
0 insulator
4 Insert the thin
wire (clip etc.).
0 insulator
qa device, optical
KEM480AAA
0 insulator
qs tape,
non-halogene
qj
qk cover, drive
qg flexible flat cable
(45
core)
qh wire (flat type)
(9
core)
1 four claws
5
7
8
9
2 two claws
3 holder, chuck assy (T)
qd wire (flat type)
(5
core)
qf tape, FFC
– Bottom view –
loading assy (T)
8
9 cover, drive
1 flexible flat cable (45 core)
6 wire (flat type)
(5
core)
Fold
Fold
2 Through the hole
3 wire (flat type) (9 core)
4 Through the hole
terminal face
terminal face
loading assy (T)
Under the guide
(Fold area)
(Fold area)
Under the guide
,QVWDOODWLRQRIIOH[LEOHIODWFDEOHFRUHZLUHIODWW\SHFRUHDQGZLUHIODWW\SHFRUH
Note: This illustration sees the loading assy (T) from bottom side.
5 tape, FFC
7 tape,
non-halogene
HBD-E385/E390/T39
20
SECTION 3
TEST MODE
COLD RESET
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the unit to
the customers.
Procedure:
1. Press the [
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the unit to
the customers.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [
x
] and [VOL –] buttons simultaneously and hold
down (around 5 seconds).
3. The message “RESET” appears on fl uorescent indicator tube,
then becomes standby states.
DEMO MODE
This mode let you lock the disc tray. When this mode is activated,
the disc will not eject when the [
This mode let you lock the disc tray. When this mode is activated,
the disc will not eject when the [
Z
] button is pressed. The message
“DEMO. LOCK” will be displayed on the fluorescent indicator
tube.
Procedure:
1. Press the [
tube.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [FUNCTION] button to select the “BD/DVD”.
3. Press the [
3. Press the [
x
] and [
Z
] buttons simultaneously and hold down
until “DEMO. LOCK” or “DEMO OFF” displayed on the
fluorescent indicator tube (around 5 seconds).
fluorescent indicator tube (around 5 seconds).
Releasing method:
Press the [
Press the [
x
] and [
Z
] buttons simultaneously and hold down until
“DEMO OFF” displayed on the fl uorescent indicator tube (around
5 seconds).
5 seconds).
PANEL TEST
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press button in order of the [DISPLAY]
[0] [0] [1]
[SUBTITLE] on the remote commander (Make the interval
when each button is pressed within two seconds).
when each button is pressed within two seconds).
3. All segments in fl uorescent indicator tube are lighted up. And
half segments in fl uorescent indicator tube are lighted up, oth-
ers half segments in fl uorescent indicator tube are lighted up,
then all segments in fl uorescent indicator tube are lighted up.
This operation is repeated.
ers half segments in fl uorescent indicator tube are lighted up,
then all segments in fl uorescent indicator tube are lighted up.
This operation is repeated.
4. When all segments in fl uorescent indicator tube are lighted up
in the state of step 3, press the [VOL +] button on the remote
commander and model information is displayed on the fl uores-
cent indicator tube.
commander and model information is displayed on the fl uores-
cent indicator tube.
Each time the [VOL +] button on the remote commander is
pressed, the display changes from destination information,
STR version in this order, and returns to the model informa-
tion display.
pressed, the display changes from destination information,
STR version in this order, and returns to the model informa-
tion display.
5. In the state of step 3, press the [FUNCTION] button on the
remote commander and “K 0” is displayed on the fluorescent
indicator tube.
indicator tube.
“K 0” value increases whenever a button or sensor on the unit
is pressed. However, once a button or sensor has been pressed,
it is no longed taken into account.
is pressed. However, once a button or sensor has been pressed,
it is no longed taken into account.
All button and sensors on the unit are pressed, “OK” and “K 9”
are alternately displayed on the fluorescent indicator tube.
are alternately displayed on the fluorescent indicator tube.
Releasing method:
To release from this mode, press the [
To release from this mode, press the [
?/1
] button.
FACTORY INITIALIZE
Return all of the unit setting to their factory defaults.
Return all of the unit setting to their factory defaults.
Note 1: Disconnect the following connections when you use this mode.
USB
LAN
Note 2: The operation in this mode must use a remote commander and TV
monitor.
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press the [HOME] button on the remote commander, and the
home menu is displayed.
3. Select
“Setup”
“Resetting”, and press the [ ] button on the
remote commander.
4. Select “Initialize Personal Information”, and press the [
]
button on the remote commander.
5. Select “OK”, and press the [
] button on the remote com-
mander.
Resetting
Easy Setup
Initialize Personal Information
Erase personal data when disposing
Erase personal data when disposing
Reset to Factory Default Settings
Initialize Personal Information
OK
Cancel
The information below will be deleted.
Do you want to proceed?
- Playback history
- Internet video utilization information
Do you want to proceed?
- Playback history
- Internet video utilization information
Click on the first or last page to see other HBD-E385 / HBD-E390 / HBD-T39 service manuals if exist.