POWER SUPPLY DURING SERVICING
• As this set has not own power supply, it does not operate indepen-
dently. Therefore, during servicing, connect it to the Pre-Main
amplifier and Tuner Unit (STR-NX5MD) of DHC-NX5MD.
If STR-NX5MD are not available, use the Power Feed Jig (PFJ-
1) and Relay Connector Jig.
In this case, after turn on the POWER switch on the Power Feed
Jig, supply power with the following methods.
Procedure:
1. Press three buttons of G (MD), A (DISC 1), and s (CD)
simultaneously.
Set
SYSTEM CONTROL terminal
SYSTEM CONTROL terminal
Connector cable (19P)
Pre-Main AMP
and Tuner Unit
AC IN
Power feed jig
(PFJ-1)
Connector cable (17P) of
attachment to power feed jig
Relay connector jig
(J-2501-197-A)
CN101 (19P)
SYSTEM CONTROL
terminal
system cable
Exclusive cable (15P)
P707, P909
Set
CDP/MD
ST
Connection:
function
button
CD AMS –
AMS –
AMS +
AMS +
FR
m
FF
M
MD AMS –
AMS –
AMS +
AMS +
FR
m
FF
M
6
Note 1: In cleaning the lens, do not apply an excessive force.
As the optical pick-up is vulnerable, application of excessive
force could damage the lens holder.
Note 2: In cleaning, do not use a cleaner other than exclusive clean-
ing liquid (KK-91 or isopropyl alcohol).
Note 3: Wipe the objective lens spirally from center toward outside.
(See Figure A)
OPTICAL PICK-UP CLEANING
1
 Remove the case. (Refer to disassembly page 13)
2
four screws
(BVTP  M2.6)
3
Open the magnet 
assy.
4
Cleaning the 
optical pick-up.
(Figure A)
7
JIG FOR CHECKING BD (MD) BOARD WAVEFORM
The special jig (J-2501-196-A) is useful for checking the waveform of the BD (MD) board. The names of terminals and the checking items
to be performed are shown as follows.
GND : Ground
I+3V : For measuring IOP (Check the deterioration of the optical pick-up laser)
IOP : For measuring IOP (Check the deterioration of the optical pick-up laser)
TE
: TRK error signal (Traverse adjustment)
VC
: Reference level for checking the signal
RF
: RF signal (Check jitter)
FE
: Focus error signal
I+3V
IOP
GND
TE
FE
VC
RF
I+3V
IOP
GND
TE
FE
VC
RF
1
7
for
MDM-7B
I+3V
CN105
IOP
TE
VC
GND
FE
RF
8
Iop DATA RECORDING AND DISPLAY WHEN OPTICAL PICK-UP AND NON-VOLATILE MEMORY (IC195 OF
BD BOARD) ARE REPLACED
The Iop value labeled on the optical pick-up can be recorded in the non-volatile memory. By recording the value, it will eliminate the need
to look at the value on the label of the optical pick-up. When replacing the optical pick-up or non-volatile memory (IC195 of BD board),
record the Iop value on the optical pick-up according to the following procedure.
Record Precedure:
1. Clicking the  ENTER/YES  button and the  A  (DISC 5) button while clicking the  m  (MD) button causes the program to enter test mode
and the message “Check” to be displayed on screen.
2. Rotate the  MD JOG  knob to display “[Service]”, and press the  ENTER/YES  button.
3. Rotate the  MD JOG  knob to display “Iop Write” (C05), and press the  ENTER/YES  button.
4. The display becomes “Ref=@@@.@” (@ is an arbitrary number) and the numbers which can be changed will blink.
5. Input the Iop value written on the optical pick-up.
To select the number : Rotate the  MD JOG  knob.
To select the digit
: Press the  MD JOG  knob.
6. When the  ENTER/YES  button is pressed, the display becomes “Measu=@@@.@” (@ is an arbitrary number).
7. As the adjustment results are recorded for the 6 value. Leave it as it is and press the  ENTER/YES  button.
8. “Complete!” will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become “Iop
Write” (C05).
9. Press the STR  REPEAT  button to complete.
Display Precedure:
1. Clicking the  ENTER/YES  button and the  A  (DISC 5) button while clicking the  m  (MD) button causes the program to enter test mode
and the message “Check” to be displayed on screen.
2. Rotate the  MD JOG  knob to display “[Service]”, and press the  ENTER/YES  button.
3. Rotate the  MD JOG  knob to display “Iop Read” (C26).
4. “@@.@/##.#” is displayed and the recorded contents are displayed.
@@.@ : indicates the Iop value labeled on the pick-up.
##.#
: indicates the Iop value after adjustment
5. To end, press the  MD JOG  button or  MENU/NO  button to display “Iop Read” (C26). Then press the  REPEAT  button.