– 17 –
4-9.
ERROR  HISTORY  MODE
4-9-1.
Entering the Error History Mode
1. Turn the VOLUME knob and display “ERR DP MODE”.
2. Press the
p (CD) button and display “total rec”.
4-9-2.
Ending the Error History Mode.
1. Press the
^ (CD) button. The display will change to “ERR
DP MODE”.
4-9-3.
Selecting the Memory to be History
Five memory types are selected by turning the VOLUME knob.
Table 4-3.
No.
Display
Contents
Function
1
total rec
Record time
Total time of laser power high.
About 20% of total recording time.
2
total play
playback time Total time of playback.
3
retry err
Total retry error
Total count of record and playback
retry error.
4
total err
All error count Total count of error.
5
err history
Error history
Error contents display.
6
err refresh
Error refresh
Clear the error histories memory
4-9-4.
Oprating the displayed histtorys.
• Record time
1. Turn the VOLUME knob and display “total rec”.
2. Press the
§ (CD) button and display “r 
 h”.
Note • r   : total time
• Playback time
1. Turn the VOLUME knob and display “total play”.
2. Press the
§ (CD) button and display “p 
 h”.
Note • p   : total time
• Total retry error
1. Turn the VOLUME knob and display “retry err”.
2. Press the
§ (CD) button and display “r   p ”.
Note • r 
: Rcord total error
• p  : Playback total error
• All error count
1. Turn the VOLUME knob and display “total err”.
2. Press the
§ (CD) button and display “total ”.
Note • total   : total error
• Error history
1. Turn the VOLUME knob and display “err history”.
2. Press the
§ (CD) button and display “0   C ”.
Note • 0  : Number of  error
• C  : Error code (See table 4-4.)
4-9-5.
Ending the displayed historys
1. Press the
§ (CD) button, the display will change to memory
types.
Table 4-4.
*
* Error refresh with optical pick-up exchange, another not execute.
Error
Contents
Code
00
No error
01
Disc error PTOC does
not read
02
DISC error
UTOC does not read
03
Loading error
04
Address does not read
Error
Contents
Code
05
Out of FOK
06
Focus does not work
07
Retry of record
08
Record retry error
09
Retry of Playback
0A
Playback retry error
– 18 –
4-10. FUNCTIONS OF OTHER BUTTONS
Table 4-3.
Button
Contents
r REC
Turns recording on/off when pressed during
continuous playback.
§ (MD)
Disc eject
Note: The erasing-protection tab in not detected during the test mode.
Recording will start regardless of the position of the erasing-protec-
tion tab when the
r REC button is pressed.
4-11.
TEST MODE DISPLAYS
Each time the POWER button pressed, the display changes in the
following order.
Note: Auto gain display and IVR display are not used in servicing.
Mode
display
Error rate
display
Address display
ADIP address
display
SUB Q address
display
Auto gain
display
IVR
display
Change over the display with the
POWER  button.
1. MODE display
Displays “TEMP ADJUST”, “CPLAY MODE”, etc..
2. Error rate display
Error rates are displayed as follows.
C1= 
 AD= 
C1= : Indicates C1 error
AD= : Indicates ADER
3. Address display
Address are displayed as follows.
h= 
 a= 
 (MO groove)
With this display, if POWER button is pressed, the following
will be displayed.
h= 
  s= 
 (MO pit and CD)
h=: Header address
s=: SUB Q address
a=: ADIP address
Note: “—” is displayed when the address cannot be read.
4. Auto gain display
Auto gain are displayed as follows.
AG = 
 / 
 [ 
 ]
     A      B     C
A= Focus servo gain coefficient
B= Tracking servo gain coefficient
C= [OK] or [NG] or [ - -] (not converged)
4-12.  MEANINGS OF OTHER DISPLAYS
Table 4-4.
Display
Contents
Light
Off
REC
Recording mode on
Recording mode off
DISC
High reflection rate disc
Low reflection rate disc
– 19 –
5-1.
PRECAUTIONS  FOR  CHECKING  LASER  DI-
ODE  EMISSION
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eyesight.
5-2.
PRECAUTIONS  FOR  USE  OF  OPTICAL
PICK-UP  (KMS-260A)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first.  Before con-
necting the connector, be careful not to remove the solder.  Also
tale adequate measures to prevent damage by static electricity.
Handle the flexible board with care as it breaks easily.
Optical pick-up flexible board
2) Set the test mode when performing adjustments.
After completing the adjustments, exit the test mode.
3) Perform the adjustments in the order shown.
4) Use the following tools and measuring devices.
• Check Disc (MD) TDYS-1
(Parts No. 4-963-646-01)
• Laser power meter LPM-8001
(Parts No. J-2501-046-A)
• Oscilloscope (Measure after preforming CAL of prove.)
• Digital voltmeter
• Thermometer
5) When observing several signals on the oscilloscope, etc., make
sure that VC and ground do not connect inside the oscilloscope.
(VC and ground will become short-circuited)
5-4.
CREATING  MO  CONTINUOUSLY
RECORDED  DISC
* This disc is used in focus bias adjustment and error rate check.
The following describes how to create a MO continuous record-
ing disc.
1. Set the test mode.
2. Insert a MO disc (blank disc) commercially available.
3. Turn the VOLUME knob display “CREC MODE”.
4. Press the
p (CD) button and display “CREC MID”.
“CREC (0300)” is displayed for a moment and recording starts.
5. Complete recording within 5 minutes.
6. Press the
^ (CD) button and stop recording.
7. Press the
§ (MD) button and remove the MO disc.
The above has been how to create a continuous recording data for
the focus bias adjustment and error rate check.
Note: Be careful not to apply vibration during continuous recording.
5-3.
PRECAUTIONS  FOR  ADJUSTMENTS
1) When replacing the following parts, perform the adjustments
and checks with 
® in the order shown in the following table.
Table  5-1.
Optical
BD board
Pick-up IC171 D101 IC101, IC121, IC192
1.Temperature
compensation
×
®
®
®
offset adjustment
2.Laser power
®
®
×
®
adjustment
3.Traverse
®
®
×
®
adjustment
4.Focus bias
®
®
×
®
adjustment
5.Error rate check
®
®
×
®
SECTION  5
ELECTRICAL  ADJUSTMENT
MD  SECTION
Pick-up
Laser tap
Flexible board
– 20 –
5-5.
TEMPERATURE  COMPENSATION  OFFSET
ADJUSTMENT
Save the temperature data at that time in the non-volatile memory
as 25 °C reference data.
Notes:
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 °C to
28 °C.  Perform it immediately after the power is turned on
when the internal temperature of the unit is the same as the
ambient temperature of 22 °C to 28 °C.
3. When D101 has been replaced, perform this adjustment after
the temperature of this part has become the ambient tempera-
ture.
Adjusting Method:
1. Turn the VOLUME knob and display “TEMP ADJUST”.
2. Press the
p (CD) button to change the display to “TEMP =
” (The numbers “   ” displayed shows you the current tem-
perature.)
3. To save the data, press the
p (CD) button.
When not saving the data, press the
^ (CD) button.
4. When the
p (CD) button is pressed, “TEMP=    SAVE” will
be displayed for some time, followed by “TEMP ADJUST”.
When the
^ (CD) button is pressed, “TEMP ADJUST” will
be displayed immediately.
Specifications:
The temperature should be within “E0-EF”, “F0-FF”, “00-0F”,
“10-1F” and “20-2F”.
5-6.
LASER  POWER  ADJUSTMENT
Connection:
Adjusting Method:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the
= 0 button or ) + button and move the optical
pick-up.)
Connect the digital voltmeter to TP1004 (I+3 V) and TP1005
(IOP) of the BD (MD) board.
2. Turn the VOLUME knob and display “LDPWR ADJUST”.
(Laser power: for adjustment)
3. Press the
p (CD) button and display “LD 0.9 mW $  ”.
4. Turn the VOLUME knob so that the reading of the laser power
meter becomes 0.82 to 0.91 mW.
Set the range control on the laser power meter to 10 mW, then
press the
p (CD) button to save the adjustment result in the
non- volatile memory.
(“LD SAVE $ 
 ” will be displayed for a moment.)
5. Then “LD 7.0 mW $ 
 ”will be displayed.
6. Turn the VOLUME knob so that the reading of the laser power
meter becomes 6.9 to 7.1 mW, press the
p (CD) button and
save the adjustment result in the nonvolatile memory.
(“LD SAVE $ 
 ” will be displayed for a moment.)
Note: Do not perform the emission with 7.0 mW more than 15 seconds
continuously.
7. Turn the VOLUME knob and display “LDPWR CHECK”.
8. Press the
p (CD) button and display “LD 0.9 mW $  ”.
Check that the reading of the laser power meter becomes 0.80
to 0.96 mW.
9. Press the
p (CD) button and display “LD 7.0 mW $  ”.
Check that the reading of the laser power meter and digital volt-
meter satisfy the specified value.
Specification:
Laser power meter reading : 7.0 ± 0.2 mW
Digital voltmeter reading : Optical pick-up displayed value ±10%
10. Press the
^ (CD) button and display “LDPWR CHECK”,
and stop the laser emission.
(The
^ (CD) button is effective at all times to stop the laser
emission.)
Optical pick-up
objective lens
laser
power meter
+
BD (MD) board
digital voltmeter
TP1004 (I+3 V)
TP1005 (IOP)
KMS260A
27X40
B0567
lOP=56.7 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/1 (
)
(Optical pick-up label)
Page of 75
Display

Click on the first or last page to see other DHC-MD313 / HCD-MD313 (serv.man2) service manuals if exist.