26
HCD-FL3
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Playback Head (Deck A).
Record/Playback/Erase Head (Deck B).
TAPE  SPEED  ADJUSTMENT
DECK B
Note:
Start the Tape Speed adjustment as below after setting to the test
mode.
In the test mode, the tape speed is high during pressing the
[CD SYNC HI-DUB] 
button.
Procedure:
1. Press
?/1
button to turn the set ON.
2. Press three buttons
x
[DISPLAY]
 and 
[CD SYNC HI-DUB]
simultaneously.
To release from the test mode, press the
?/1
button.
Mode:  Playback
1. Insert the WS-48B into the deck B.
2. Press the hH button on the deck B.
3. Press the 
[CD SYNC HI-DUB]
 button in playback mode.
Then at HIGH speed mode.
4. Adjust RV1001 on the SW board so that frequency counter reads
6,000 
± 180 Hz.
5. Press the 
[CD SYNC HI-DUB]
 button.
Then back to NORMAL speed mode.
6. Adjust RV1002 on the SW board so that frequency counter reads
3,000 
± 90 Hz.
Adjustment Location: SW board
Sample Value of Wow and Flutter: 0.3% or less W. RMS (JIS)
(WS-48B)
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
SP
REALY
baord
CN804
set
test tape
P-4-A100
(10 kHz, –10 dB)
pin 
5
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
pin 
3
pin 
2
L
R
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
SP RELAY board
CN804 Pin 
3
 (GND)
SP RELAY board
CN804
Pin 
2
 (L-CH)
Pin 
5
 (R-CH)
frequency counter
forward
reverse
27
HCD-FL3
4. Mode:  Record
5. Mode:  Playback
6. Confirm the play back signal recorded in step 3 becomes
adjustable level as follows.
If these levels are not adjustable level, adjust the RV53 (R-CH)
on the SP RELAY board to repeat steps 4 and 5.
Adjustable level:
CN804 PB level:  47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location:  SP RELAY board
REC  BIAS  ADJUSTMENT   DECK B
Procedure:
In the MC test mode, the “REC memory mode” is convenient for
this adjustment. In the “REC memory mode” , when the REC starts
the input signal FUNCTION is switched to VIDEO automatically.
When the REC stops, the tape returns near to the recording start
position.
1. Press 
[MD $VIDEO%]
 button to select VIDEO. (This step is not
necessary if the above test mode has already been set)
2. Insert a tape into deck B.
3. After press 
[REC PAUSE/START]
 button, press 
[REC PAUSE/
START]
 button, then recording start.
4. Mode:  Record
5. Mode:  Playback
6. Confirm the playback signal recorded in step 3 becomes
adjustable level as follows.
If these levels are not adjustable level, adjust the RV2 (L-CH)
and RV52 (R-CH) on the SP RELAY board to repeat steps 4
and 5.
Adjustable level: Playback output of 315 Hz to playback output
of 10 kHz:  
±1.0 dB
Adjustment Location:  SP RELAY board
REC  LEVEL  ADJUSTMENT   DECK B
Procedure:
In the MC test mode, the “REC memory mode” is convenient for
this adjustment. In the “REC memory mode” , when the REC starts
the input signal FUNCTION is switched to VIDEO automatically.
When the REC stops, the tape returns near to the recording start
position.
1. Press 
[MD $VIDEO%]
 button to select VIDEO. (This step is not
necessary if the above test mode has already been set)
2. Insert a tape into deck B.
3. After press 
[REC PAUSE/START]
 button, press 
[REC PAUSE/
START]
 button, then recording start.
attenuator
set
DSP board
MD (AUDIO) (J701)
1) 315 Hz
2) 10 kHz
50 mV (–23.8 dB)
600 
blank tape
CN-123
AF OSC
+
set
recorded
portion
SP RELAY board
CN804 Pin 
3
 (GND)
SP RELAY board
CN804
Pin 
2
 (L-CH)
Pin 
5
 (R-CH)
level meter
set
DSP board
MD (VIDEO) (J701) 
315 Hz, 50 mV (–23.8 dB)
blank tape
CS-123
600 
attenuator
AF OSC
+
set
recorded
portion
SP RELAY board
CN804 Pin 
3
 (GND)
SP RELAY board
CN804
Pin 
5
 (R-CH)
level meter
TAPE SPEED
ADJUSTMENT
RV1002
RV1001
(NORMAL)  (HIGH)
CN1001
– SW BOARD (Component Side) –
CN804
10
1
– SP RELAY BOARD (Conductor Side) –
REC BIAS
ADJUSTMENT
REC LEVEL
ADJUSTMENT
(L-CH)
(R-CH)
RV52 RV2
RV53
28
HCD-FL3
CD SECTION
Note:
1.
CD Block is basically designed to operate without adjustment. Therefore,
check each item in order given.
2.
Use LUV-P01 (4-999-032-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10M
Ω impedance.
4.
Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S-CURVE  CHECK
Procedure :
1. Connect an oscilloscope to TP (FEO).
2. Connect between TP (FEI) and TP (DVC) ( 1.65 V) by lead
wire.
3. Turn the power ON.
4. Load a disc (LUV-P01) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
5. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 2 
± 0.5 Vp-p.
6. After check, remove the lead wire connected in step 2.
Note:
• Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF  LEVEL  CHECK
Procedure :
1. Connect an oscilloscope CH1 to TP (RFDC) and CH2 to TP
(RFAC).
2. Turn the power ON.
3. Load a disc (LUV-P01) and playback.
4. Confirm that oscilloscope waveform is clear and check if RF
signal level is correct or not.
BD board
Oscilloscope
TP(FEO)
TP(DVC)
symmetry
S-curve waveform
within 2 
±
0.5Vp-p
A
B
TP(RFDC)
TP(RFAC)
BD board
oscilloscope
TP(DVC)
Note:
Clear RF signal waveform means that the shape “ 
◊ ”  can be clearly
distinguished at the center of the waveform.
E-F BALANCE (1  TRACK  JUMP)  ADJUSTMENT
Procedure :
1. Connect an oscilloscope to TP (TEO) and TP (DVC).
2. Turn the power ON.
3. Load a disc (LUV-P01) and playback the number nine track.
4. Press the hH button. (Becomes the 1 track jump mode.)
5. Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
6. Adjust RV101 on the BD board so that the center of waveform
becomes the same voltage of DVC. (i.e.  A=0V)
Connecting and Adjustment Location: BD board
RF signal waveform
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 0.65 
±
0.15Vp-p (RFDC)
1.1 
±
0.4Vp-p (RFAC)
TP(TEO)
TP(DVC)
BD board
oscilloscope
level=1.0 
±
0.5Vp-p
symmetry
A (DC voltage)
center of
waveform
B
DVC
1 track jump waveform
HCD-FL3
29
29
Connecting and Adjustment Location:
– BD BOARD (Component Side) –
TP
(DVC)
TP
(FEO)
TP
(FEI)
TP
(RFDC)
TP
(RFAC)
TP
(TEO)
– BD BOARD (Conductor Side) –
RV101
E-F BALANCE
(1 TRACK JUMP)
ADJUSTMENT
Page of 127