HCD-FL3
SECTION  6
MECHANICAL  ADJUSTMENTS
SECTION  7
ELECTRICAL  ADJUSTMENTS
0 dB=0.775 V
DECK  SECTION
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless otherwise
specified.
• Test Tape
RECORD/PLAYBACK  HEAD  AZIMUTH  ADJUSTMENT
DECK A      DECK B
Note:
  Perform this adjustments for both decks
Procedure:
1. Mode:  Playback
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
set
SP RELAY board
CN804
Pin 
2
 (L-CH)
Pin 
5
 (R-CH)
SP RELAY board
CN804
Pin 
3
 (GND)
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
6.96 N • m to 14.02 N • m
71 to 143 g • cm
(0.98 – 1.99 oz • inch)
9.80 N • m
100 g or more
(3.53 oz or more)
9.80 N • m
100 g or more
(3.53 oz or more)
Mode
Torque meter
CQ-102C
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
Meter reading
FWD
FWD
back tension
REV
REV
back tension
FF/REW
FWD tension
REV tension
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
26
HCD-FL3
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Playback Head (Deck A).
Record/Playback/Erase Head (Deck B).
TAPE  SPEED  ADJUSTMENT
DECK B
Note:
Start the Tape Speed adjustment as below after setting to the test
mode.
In the test mode, the tape speed is high during pressing the
[CD SYNC HI-DUB] 
button.
Procedure:
1. Press
?/1
button to turn the set ON.
2. Press three buttons
x
[DISPLAY]
 and 
[CD SYNC HI-DUB]
simultaneously.
To release from the test mode, press the
?/1
button.
Mode:  Playback
1. Insert the WS-48B into the deck B.
2. Press the hH button on the deck B.
3. Press the 
[CD SYNC HI-DUB]
 button in playback mode.
Then at HIGH speed mode.
4. Adjust RV1001 on the SW board so that frequency counter reads
6,000 
± 180 Hz.
5. Press the 
[CD SYNC HI-DUB]
 button.
Then back to NORMAL speed mode.
6. Adjust RV1002 on the SW board so that frequency counter reads
3,000 
± 90 Hz.
Adjustment Location: SW board
Sample Value of Wow and Flutter: 0.3% or less W. RMS (JIS)
(WS-48B)
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
SP
REALY
baord
CN804
set
test tape
P-4-A100
(10 kHz, –10 dB)
pin 
5
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
pin 
3
pin 
2
L
R
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
SP RELAY board
CN804 Pin 
3
 (GND)
SP RELAY board
CN804
Pin 
2
 (L-CH)
Pin 
5
 (R-CH)
frequency counter
forward
reverse
27
HCD-FL3
4. Mode:  Record
5. Mode:  Playback
6. Confirm the play back signal recorded in step 3 becomes
adjustable level as follows.
If these levels are not adjustable level, adjust the RV53 (R-CH)
on the SP RELAY board to repeat steps 4 and 5.
Adjustable level:
CN804 PB level:  47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location:  SP RELAY board
REC  BIAS  ADJUSTMENT   DECK B
Procedure:
In the MC test mode, the “REC memory mode” is convenient for
this adjustment. In the “REC memory mode” , when the REC starts
the input signal FUNCTION is switched to VIDEO automatically.
When the REC stops, the tape returns near to the recording start
position.
1. Press 
[MD $VIDEO%]
 button to select VIDEO. (This step is not
necessary if the above test mode has already been set)
2. Insert a tape into deck B.
3. After press 
[REC PAUSE/START]
 button, press 
[REC PAUSE/
START]
 button, then recording start.
4. Mode:  Record
5. Mode:  Playback
6. Confirm the playback signal recorded in step 3 becomes
adjustable level as follows.
If these levels are not adjustable level, adjust the RV2 (L-CH)
and RV52 (R-CH) on the SP RELAY board to repeat steps 4
and 5.
Adjustable level: Playback output of 315 Hz to playback output
of 10 kHz:  
±1.0 dB
Adjustment Location:  SP RELAY board
REC  LEVEL  ADJUSTMENT   DECK B
Procedure:
In the MC test mode, the “REC memory mode” is convenient for
this adjustment. In the “REC memory mode” , when the REC starts
the input signal FUNCTION is switched to VIDEO automatically.
When the REC stops, the tape returns near to the recording start
position.
1. Press 
[MD $VIDEO%]
 button to select VIDEO. (This step is not
necessary if the above test mode has already been set)
2. Insert a tape into deck B.
3. After press 
[REC PAUSE/START]
 button, press 
[REC PAUSE/
START]
 button, then recording start.
attenuator
set
DSP board
MD (AUDIO) (J701)
1) 315 Hz
2) 10 kHz
50 mV (–23.8 dB)
600 
blank tape
CN-123
AF OSC
+
set
recorded
portion
SP RELAY board
CN804 Pin 
3
 (GND)
SP RELAY board
CN804
Pin 
2
 (L-CH)
Pin 
5
 (R-CH)
level meter
set
DSP board
MD (VIDEO) (J701) 
315 Hz, 50 mV (–23.8 dB)
blank tape
CS-123
600 
attenuator
AF OSC
+
set
recorded
portion
SP RELAY board
CN804 Pin 
3
 (GND)
SP RELAY board
CN804
Pin 
5
 (R-CH)
level meter
TAPE SPEED
ADJUSTMENT
RV1002
RV1001
(NORMAL)  (HIGH)
CN1001
– SW BOARD (Component Side) –
CN804
10
1
– SP RELAY BOARD (Conductor Side) –
REC BIAS
ADJUSTMENT
REC LEVEL
ADJUSTMENT
(L-CH)
(R-CH)
RV52 RV2
RV53
28
HCD-FL3
CD SECTION
Note:
1.
CD Block is basically designed to operate without adjustment. Therefore,
check each item in order given.
2.
Use LUV-P01 (4-999-032-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10M
Ω impedance.
4.
Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S-CURVE  CHECK
Procedure :
1. Connect an oscilloscope to TP (FEO).
2. Connect between TP (FEI) and TP (DVC) ( 1.65 V) by lead
wire.
3. Turn the power ON.
4. Load a disc (LUV-P01) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
5. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 2 
± 0.5 Vp-p.
6. After check, remove the lead wire connected in step 2.
Note:
• Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF  LEVEL  CHECK
Procedure :
1. Connect an oscilloscope CH1 to TP (RFDC) and CH2 to TP
(RFAC).
2. Turn the power ON.
3. Load a disc (LUV-P01) and playback.
4. Confirm that oscilloscope waveform is clear and check if RF
signal level is correct or not.
BD board
Oscilloscope
TP(FEO)
TP(DVC)
symmetry
S-curve waveform
within 2 
±
0.5Vp-p
A
B
TP(RFDC)
TP(RFAC)
BD board
oscilloscope
TP(DVC)
Note:
Clear RF signal waveform means that the shape “ 
◊ ”  can be clearly
distinguished at the center of the waveform.
E-F BALANCE (1  TRACK  JUMP)  ADJUSTMENT
Procedure :
1. Connect an oscilloscope to TP (TEO) and TP (DVC).
2. Turn the power ON.
3. Load a disc (LUV-P01) and playback the number nine track.
4. Press the hH button. (Becomes the 1 track jump mode.)
5. Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
6. Adjust RV101 on the BD board so that the center of waveform
becomes the same voltage of DVC. (i.e.  A=0V)
Connecting and Adjustment Location: BD board
RF signal waveform
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 0.65 
±
0.15Vp-p (RFDC)
1.1 
±
0.4Vp-p (RFAC)
TP(TEO)
TP(DVC)
BD board
oscilloscope
level=1.0 
±
0.5Vp-p
symmetry
A (DC voltage)
center of
waveform
B
DVC
1 track jump waveform
Page of 127