Sony DAV-TZ210 / DAV-TZ230 / DAV-TZ510 / DAV-TZ630 / DAV-TZ710 / HBD-TZ210 / HBD-TZ230 / HBD-TZ510 / HBD-TZ630 / HBD-TZ710 Service Manual ▷ View online
HBD-TZ210/TZ230/TZ510/TZ630/TZ710
17
2-13. MS-203 BOARD
2-14. BASE UNIT
2
three claws
3
MS-203 board
4
DC motor
1
screw
(M
1.7
u 2.5)
1
two claws
3
two claws
2
chuck cam
4
base unit
HBD-TZ210/TZ230/TZ510/TZ630/TZ710
18
2-15. OPTICAL PICK-UP
2
FFC holder
3
two insulator screws
4
two insulator screws
5
two insulators
6
two insulators
7
optical pick-up
(KHM-313CAA)
1
two claws
HBD-TZ210/TZ230/TZ510/TZ630/TZ710
19
SECTION 3
TEST MODE
Note: Incorrect operations may be performed if the test mode is not
entered properly.
In this case, press the [?/1] button to turn the power off, and
retry to enter the test mode.
retry to enter the test mode.
1. Cold Reset
• The cold reset clears all data including preset data stored
in the RAM to initial conditions. Execute this mode when
returning the set to the customers.
returning the set to the customers.
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press three buttons [
N
], [FUNCTION] and [
?/1
] simultane-
ously.
3. When this button is operated, display as “COLD RESET” for
a while and all of the settings are reset.
2. Panel Test Mode
• This mode is used to check the software version, FL and
KEY.
2-1. Display Test Mode
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. While pressing the [
x
] and the [
N
] buttons simultaneously,
turn the [VOLUME] control in the direction of (+).
3. When the display test mode is activated, all segments are
turned on.
4. To exit from this mode, while pressing the [
x
] and the [
N
]
buttons simultaneously, turn the [VOLUME] control in the di-
rection of (+).
rection of (+).
2-2. Version Test Mode
Procedure:
1. When the display test mode is activated, press the [FUNC-
Procedure:
1. When the display test mode is activated, press the [FUNC-
TION] button and the message “KZ2” (TZ210/TZ230),
“KZ4L” (TZ510), “KZ5” (TZ630), “KZ8L” (TZ710) are dis-
played, the version test mode is activated.
“KZ4L” (TZ510), “KZ5” (TZ630), “KZ8L” (TZ710) are dis-
played, the version test mode is activated.
2. Whenever the [FUNCTION] button is pressed, the display
changes in the following order.
“KZ2” (Model name)
t “NA
*1
” (Destination)
t MC Version
*1: NA changes depending on destination.
3. Press the [REC TO USB] button when the MC version is on
display. The date of software production is displayed.
4. Press the [REC TO USB] button again and the version is dis-
played.
5. To exit from this mode, while pressing the [
x
] and the [
N
]
buttons simultaneously, turn the [VOLUME] control in the di-
rection of (+).
rection of (+).
2-3. FL Pattern Test Mode
Procedure:
1. When the display test mode is activated, press the [
Procedure:
1. When the display test mode is activated, press the [
Z
] button,
to select the FL pattern test mode. When the FL pattern test
mode, half segments of FL display.
mode, half segments of FL display.
2. Press the [
Z
] button, half segments of FL display.
3. Next press the [
Z
] button, all segments of FL display is turn
on.
4. To exit from this mode, while pressing the [
x
] and the [
N
]
buttons simultaneously, turn the [VOLUME] control in the di-
rection of (+).
rection of (+).
2-4. Key Test Mode
Procedure:
1. When the display test mode is activated, press the [
Procedure:
1. When the display test mode is activated, press the [
?/1
] but-
ton, to select the key test mode.
2. To enter the KEY test mode, the fl uorescent indicator displays
“K0 V0”. Each time an another button is pressed, “KEY” value
increases. However, once a button is pressed, it is no longer
taken into account. When all keys are pressed correctly, “K6
V0” is displayed.
increases. However, once a button is pressed, it is no longer
taken into account. When all keys are pressed correctly, “K6
V0” is displayed.
3. When the [VOLUME] control is turned in the direction of (+),
“V0” is changed to “V1”, then ... “V9”.
When the [VOLUME] control is turned in the direction of (–),
“V0” is changed to “V9”, then ... “V1”.
“V0” is changed to “V9”, then ... “V1”.
4. To exit from this mode, while pressing the [
x
] and the [
N
]
buttons simultaneously, turn the [VOLUME] control in the di-
rection of (+).
rection of (+).
3. Disc Tray Lock
• The disc tray lock function for the antitheft of an demonstra-
tion disc in the store is equipped.
Setting Procedure :
1. Press the [
1. Press the [
?/1
] button to turn the set on.
2. Press the [FUNCTION] button to set DVD/CD function.
3. Insert a disc.
4. Press the [
3. Insert a disc.
4. Press the [
x
] button and the [
Z
] button simultaneously for fi ve
seconds.
5. The message “LOCKED” is displayed and the tray is locked.
Releasing Procedure :
1. Press the [
Releasing Procedure :
1. Press the [
x
] button and the [
Z
] button simultaneously for fi ve
seconds again.
2. The message “UNLOCKED” is displayed and the tray is un-
locked.
Note: When “LOCKED” is displayed, the tray lock is not released by
turning power on/off with the [?/1] button.
4. DVD Version Display
• The STR and DVD microprocessor versions are displayed.
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the set on.
2. Press the [
N
] button and the [
?/1
] button simultaneously for
three seconds. SC version display is presented.
3. Pressing the [FUNCTION] button presents a DV version dis-
play. Pressing the [FUNCTION] button again returns to the SC
version display.
version display.
4. To exit from this mode, press any button other than the [FUNC-
TION] button.
5. Product Out
• This mode moves the optical pick-up to the position durable
to vibration and clears all data including preset data stored
in the STR RAM to initial conditions. Use this mode when
returning the set to the customer after repair.
in the STR RAM to initial conditions. Use this mode when
returning the set to the customer after repair.
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press the [FUNCTION] button to set the function “DVD/CD”.
3. Remove all discs.
4. While pressing the [
3. Remove all discs.
4. While pressing the [
x
] and the [
Z
] buttons simultaneously,
turn the [VOLUME] control in the direction of (+).
5. Displayed to message “SERVICE IN” on the fl uorescent indi-
cator tube when pressing in turn the [4]
t [DVD MENU] t
[CLEAR] buttons on the remote commander.
6. After the “STANDBY” blinking display fi nishes, the message
“MECHA LOCK”
h “UNPLUG” is displayed on the fl uo-
rescent indicator tube disconnect the AC power plug, then the
product out mode is set.
product out mode is set.
The STR RAM initialization is executed upon a next power-on
after the power is turned off.
after the power is turned off.
HBD-TZ210/TZ230/TZ510/TZ630/TZ710
20
6. Color System Change (EXCEPT CND, AEP, UK, E32,
CH, RU, AR, MX, TW models)
• Color system change to video signal format (NTSC/PAL).
• Color system change to video signal format (NTSC/PAL).
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the set on.
2. Press the [FUNCTION] button to set the function “DVD/CD”.
3. Press the [
3. Press the [
?/1
] button to turn the set OFF.
4. Press two buttons [FUNCTION] and [
?/1
] simultaneously,
and the display of fl uorescent indicator tube changes to “COL-
OR PAL” or “COLOR NTSC”.
OR PAL” or “COLOR NTSC”.
7. PROTECTION FACTOR (SD DETECTION/
DC DETECTION/TSD DETECTION) IDENTIFICATION
TEST MODE
TEST MODE
When an error is detected, the FL tube alternately displays
“PROTECTOR” h “PUSH POWER”.
“PROTECTOR” h “PUSH POWER”.
r
Press the [
?/1
] button.
* Buttons other than the [
?/1
] button are invalid.
“STANDBY” blinks three times on the FL tube.
r
r
The protection release state (POWER OFF) is established.
(No FL tube display)
r Press the [
(No FL tube display)
r Press the [
?/1
] button two times.
The power to the system turns on, and the normal operation is
established. (Restore)
established. (Restore)
During the protection state:
1. If the AC plug is connected or disconnected during the protec-
1. If the AC plug is connected or disconnected during the protec-
tion state, the protection state is released, and the normal op-
eration is established. (The protection state is not maintained.)
eration is established. (The protection state is not maintained.)
2. The protection factor is displayed by pressing the [RETURN]
t [3] t [2] t [0] t [0] t [ANGLE] buttons of the re-
mote commander.
(during the “PROTECTOR” h “PUSH POWER” display).
k When SD is detected: Repeats
“SD
DETECT”
h “PROTECTOR”.
k When DC is detected: Repeats
“DC
DETECT”
h “PROTECTOR”.
k When TSD is detected: Repeats
“TMP
DETECT”
h “PROTECTOR”.
PL: SD detection
When the “L” output from the SD (shutdown) port on the
S-MASTER POWER Driver Shutdown and voltage descent
(15V or less) of 26V power supply (PVDD) are detected.
S-MASTER POWER Driver Shutdown and voltage descent
(15V or less) of 26V power supply (PVDD) are detected.
DC
detection
When the “L” output from the power/speaker error detection
circuit (DC detection port) is detected for two seconds con-
tinually, the power system other than that of the FL tube is
turned off, and the protection state is established.
circuit (DC detection port) is detected for two seconds con-
tinually, the power system other than that of the FL tube is
turned off, and the protection state is established.
TSD
detection
When the “L” output from the thermal shutdown port
(TSDM) on the motor driver is detected.
(TSDM) on the motor driver is detected.
DVD SECTION
8-1. GENERAL DESCRIPTION
• The IOP measurement allows you to make diagnosis and ad-
justment simply by using the remote commander and moni-
tor TV. The instructions, diagnosis results, etc. are given on
the on-screen display (OSD).
tor TV. The instructions, diagnosis results, etc. are given on
the on-screen display (OSD).
Be sure to execute the IOP measurement when a BU (Base
Unit) is replaced.
8-2. HOW TO ENTER TEST MODE
While pressing the [
While pressing the [
x
] and the [
Z
] buttons simultaneously, turn
the [VOLUME] control in the direction of (+) with the DVD play-
er in power on.
The Test Mode starts, displayed “SERVICE IN” on this model
display then the menu shown below will be displayed on the TV
screen.
* The display of the “Model Name” of the “Remocon Diagnosis
er in power on.
The Test Mode starts, displayed “SERVICE IN” on this model
display then the menu shown below will be displayed on the TV
screen.
* The display of the “Model Name” of the “Remocon Diagnosis
Menu” change with the model and the destination. Refer to
below on the model name.
below on the model name.
TZ210
:
KZ2
TZ230
:
KZ2
TZ510
:
KZ4L
TZ630
:
KZ5
TZ710
:
KZ8L
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. USB Test Mode Setting
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. USB Test Mode Setting
Model Name
IF-con
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
: KZ2_XX
*
1
*1: Changes depending on destination
The menu above is the Remocon Diagnosis Menu screen which
consists of fi ve main functions. At the bottom of the menu screen,
the model name and IF-con version. To exit from the Test Mode,
press the [
consists of fi ve main functions. At the bottom of the menu screen,
the model name and IF-con version. To exit from the Test Mode,
press the [
?/1
] button on the remote commander.
8-3. EXECUTING IOP MEASUREMENT
In order to execute IOP measurement, the following standard pro-
cedures must be followed.
In order to execute IOP measurement, the following standard pro-
cedures must be followed.
(1) In power on, while pressing the [
x
] and the [
Z
] buttons simul-
taneously, turn the [VOLUME] control in the direction of (+).
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
*1: Changes depending on destination
5. USB Test Mode Setting
Model Name : KZ2_XX
*
1
• Abbreviation
AR :
AR :
Argentina
model
CH
: Chinese model
CND : Canadian model
E32
E32
: 110 – 240V AC area in E model
MX
: Mexican model
RU
: Russian model
TW :
Taiwan
model
Ver. 1.1