DOWNLOAD Sony DAV-SZ1000W / HBD-SZ1000W Service Manual ↓ Size: 5.3 MB | Pages: 82 in PDF or view online for FREE

Model
DAV-SZ1000W HBD-SZ1000W
Pages
82
Size
5.3 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
dav-sz1000w-hbd-sz1000w.pdf
Date

Sony DAV-SZ1000W / HBD-SZ1000W Service Manual ▷ View online

HBD-SZ1000W
17
2-18.  HOW  TO  BEND  FLEXIBLE  FLAT  CABLE
‡IOH[LEOHIODWFDEOHFRUHOHQJWKPP5HI1R
‡IOH[LEOHIODWFDEOHFRUHOHQJWKPP5HI1R
The upper side
is terminal side. 
The upper side
is terminal side. 
The upper side
is terminal side. 
The upper side
is terminal side. 
The upper side
is terminal side. 
MAIN board
(CN5001)
: Mountain fold
: Valley fold
23 mm
12 mm
37 mm
18 mm
20 mm
DISPLAY board
(CN501)
DISPLAY board
(CN502)
PANEL board
(CN203)
210 mm
38 mm
13 mm
49 mm
‡IOH[LEOHIODWFDEOHFRUHOHQJWKPP5HI1R
47 mm
MAIN board
(CN5005)
S-AIR INC board
(CN203)
33 mm
The lower side
is terminal side. 
‡IOH[LEOHIODWFDEOHFRUHOHQJWKPP5HI1R
‡IOH[LEOHIODWFDEOHFRUHOHQJWKPP5HI1R
‡IOH[LEOHIODWFDEOHFRUHOHQJWKPP5HI1R
The lower side
is terminal side. 
The upper side
is terminal side. 
MAIN board
(CN3008)
IO board
(CN102)
42 mm
38 mm
The lower side
is terminal side. 
8 mm
14 mm
148 mm
The upper side
is terminal side. 
45 mm
95 mm
10 mm
MAIN board
(CN1502)
CDM85 (MB) assy
62 mm
195 mm
13 mm
The lower side
is terminal side. 
MAIN board
(CN1502)
optical pick-up
(KHM-313CAA)
The lower side
is terminal side. 
HBD-SZ1000W
18
SECTION  3
TEST  MODE
Note: Incorrect operations may be performed if the test mode is not 
entered properly.
 
In this case, press the [
?/1] button to turn the power off, and 
retry to enter the test mode.
COLD  RESET
The cold reset clears all data including preset data stored in the 
RAM to initial conditions. Execute this mode when returning the 
set to the customers.
Procedure:
1.  Press the [
?/1
] button to turn the power on. 
2.  Press three buttons [
N
], [FUNCTION] and [
?/1
] simultane-
ously.
3.  When this button is operated, display as “RESET” for a while 
and all of the settings are reset. 
PANEL  TEST  MODE
This mode is used to check the software version, FL and KEY.
1.  Display Test Mode
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press three buttons [
x
], [VOLUME +] and the [
N
] buttons 
simultaneously.
3.  When the display test mode is activated, all segments are 
turned on. When the mode in, “REC TO USB” is turn off.
Releasing method:
Press three buttons [
x
], [VOLUME +] and the [
N
] buttons si-
multaneously.
2.  Version Test Mode
Procedure:
1.  When the display test mode is activated, press the [FUNC-
TION] button and the model name is displayed, the version 
test mode is activated.
2.  Whenever the [FUNCTION] button is pressed, the display 
changes in the following order.
 
   
DX (Model name) 
t (Destination) t MC Version 
3.  Press the [REC TO USB] button when the MC version is on 
display. The date of software production is displayed.
4.  Press the [REC TO USB] button again and the version is dis-
played.
Releasing method:
Press three buttons [
x
], [VOLUME +] and the [
N
] buttons si-
multaneously.
3.  FL Pattern Test Mode
Procedure:
1.  When the display test mode is activated, press the [
Z
] button, 
to select the FL pattern test mode. When the FL pattern test 
mode, half segments of FL display and “REC TO USB” are 
turn on.
2.  Press the [
Z
] button, half segments of fl uorescent  indicator 
tube and “REC TO USB” are turned off.
Releasing method:
Press three buttons [
x
], [VOLUME +] and the [
N
] buttons si-
multaneously.
4.  Key Test Mode
Procedure:
1.  When the display test mode is activated, press the [
?/1
] but-
ton, to select the key test mode.
2.  To enter the KEY test mode, the fl uorescent indicator displays 
“K0”. Each time an another button is pressed, “KEY” value 
increases. However, once a button is pressed, it is no longer 
taken into account. When all keys are pressed correctly, “K8” 
is displayed.
Releasing method:
Press three buttons [
x
], [VOLUME +] and the [
N
] buttons si-
multaneously.
DISC  TRAY  LOCK
The disc tray lock function for the antitheft of an demonstration 
disc in the store is equipped.
Procedure:
1.  Press the [
?/1
] button to turn the set on.
2.  Press the [FUNCTION] button to set DVD function.
3.  Insert a disc.
4. Press 
the 
[
x
] button and the [
Z
] button simultaneously for fi ve 
seconds.
5.  The message “LOCKED” is displayed and the tray is locked.
Releasing method:
1. Press 
the 
[
x
] button and the [
Z
] button simultaneously for fi ve 
seconds again.
2.  The message “UNLOCKED” is displayed and the tray is un-
locked.
Note: When “LOCKED” is displayed, the tray lock is not released by 
turning power on/off with the [
?/1] button.
VERSION  DISPLAY
The STR and DVD microprocessor versions are displayed.
Procedure:
1.   Press the [
?/1
] button to turn the set on.
2.   Press two buttons [
N
] and [
?/1
] simultaneously for three sec-
onds. SC version display is presented.
3.   Pressing the [FUNCTION] button presents a DV version dis-
play. Pressing the [FUNCTION] button again returns to the SC 
version display.
Releasing method:
Press any button other than the [FUNCTION] button.
DVD  VERSION  DISPLAY
The DVD versions is displayed.
Procedure:
1.   In the standby status, press two buttons [
N
] and [
?/1
] simul-
taneously.
2.   The DVD version is displayed.
Releasing method:
Press the [
\/1] button.
HBD-SZ1000W
19
PRODUCT  OUT
This mode moves the optical pick-up to the position durable to 
vibration and clears all data including preset data stored in the STR 
RAM to initial conditions. Use this mode when returning the set to 
the customer after repair.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [FUNCTION] button to set the function “DVD/CD”.
3.  Remove all discs, and then press three buttons [
x
], [
Z
] and 
[VOLUME+] simultaneously.
4.  Displayed to message “SERVICE” on the fl uorescent indica-
tor tube when pressing in turn the [4] 
t [DVD MENU] t 
[CLEAR] buttons on the remote commander.
5.  After the “STANDBY” blinking display fi nishes, the message  
“LOCKED” 
h “UNPLUG” is displayed on the fl uorescent 
indicator tube disconnect the AC power plug, then the product 
out mode is set.
 
The STR RAM initialization is executed upon a next power-on 
after the power is turned off.
PROTECTION  FACTOR (SD  DETECTION/DC DETEC-
TION/TSD  DETECTION) IDENTIFICATION  TEST  MODE
When an error is detected, the FL tube alternately displays 
“PROTECT” 
h “PUSH PWR”.
    r  Press the [
?/1
] button.
 
* Buttons other than the [
?/1
] button are invalid.
“STANDBY” blinks three times on the FL tube.
    
r
The protection release state (POWER OFF) is established.
(No FL tube display) 
    
r  Press the [
?/1
] button two times.
The power to the system turns on, and the normal operation is 
established. (Restore) 
During the protection state: 
1.   If the AC plug is connected or disconnected during the protec-
tion state, the protection state is released, and the normal op-
eration is established. (The protection state is not maintained.) 
2.   The protection factor is displayed by pressing the [RETURN] 
t [3] t [2] t [0] t [0] t [ANGLE] buttons of the re-
mote commander.
 
(during the “PROTECT” 
h “PUSH PWR” display).
 
k  When SD is detected: Repeats
   “SD 
ERR” 
h “PROTECT”.
 
k  When DC is detected: Repeats 
   “DC 
ERR” 
h “PROTECT”.
 
k  When TSD is detected: Repeats 
   “TMP 
ERR” 
h “PROTECT”.
PL:  SD detection
 
When the “L” output from the SD (shutdown) port on the 
S-MASTER POWER Driver Shutdown and voltage descent 
(15V or less) of 30V power supply (PVDD) are detected.
 DC 
detection
 
When the “L” output from the power/speaker error detection 
circuit (DC detection port) is detected for two seconds con-
tinually, the power system other than that of the FL tube is 
turned off, and the protection state is established.
 TSD 
detection
 
When the “L” output from the thermal shutdown port 
(TSDM) on the motor driver is detected.
Releasing method:
Press the buttons on the remote commander in the order given be-
low.
[RETURN] 
t [3] t [2] t [0] t [0] t [ANGLE]
COLOR  SYSTEM  CHANGE
Color system change to video signal format (NTSC/PAL).
Procedure:
In Standby mode, press two buttons [FUNCTION] and [
?/1
] si-
multaneously, and the display of fl uorescent indicator tube changes 
to “PAL” or “NTSC”.
D. C. A. C.  TEST  MODE
The D. C. A. C. (Digital Cinema Auto Calibration) test is executed.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Insert ECM-AC2 supplied as an accessory into the [AUDIO 
IN 4/A. CAL MIC] jack.
3.  Press three buttons [
x
], [
Z
] and [REC TO USB] simultane-
ously.
4. Confi rm that the following are shown on the fl uorescent indi-
cator tube.
 
1  Microphone inserted/non-inserted detection display and 
the STEREO/MONO detection display.
 
2  Presence of digital audio input to the μ-com (OK: input, 
NG: no input).
 
3  The value of microphone input to the μ-com(shown 
“255h”).
 
 
* * *  * *  * * *
1
1 “NON” 
: Not detected
“ST” : 
STEREO
“MN” : 
MONO
2 “OK” : 
Input
“NG” 
: No input
3 0 to 255 (Changes in real time)
2
3
Releasing method:
Press three buttons [
x
], [
Z
] and [REC TO USB] simultaneously.
HBD-SZ1000W
20
2.  Select “2. Drive Manual Operation” by pressing the [2] button 
on the remote commander. The screen will appear as shown.
 
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to Top Menu
3.  Select “3. Manual Adjustment” by pressing the [3] button on 
the remote commander. The screen will appear as shown.
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
O o  Change Value
[RETURN] Return to previous menu
4.  Select “6. IOP” by pressing the [6] button on the remote com-
mander.
5.  Wait until a hexadecimal number appear.
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 4D:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
[RETURN] Return to previous menu
O o  Change Value
6.  Convert each data from hexadecimal to decimal using conver-
sion table.
7. Please 
fi nd the label on the rear of the BU (Base Unit).
 
The default IOP value is written in the label.
8.  Subtract between these two values.
9.  If the remainder is smaller than 93 (decimal), then it is OK. 
However if the value is higher than 93, then the BU is defec-
tive and need to be change.
10.  Press the [RETURN] button on the remote commander to re-
turn back to previous menu.
11.  Press the [0] button on the remote commander to return to Top 
Menu.
DVD  SERVICE  MODE
The IOP measurement allows you to make diagnosis and adjust-
ment simply by using the remote commander and monitor TV. The 
instructions, diagnosis results, etc. are given on the on-screen dis-
play (OSD).
Be sure to execute the IOP measurement when a BU (Base Unit) 
is replaced.
1.  How To Enter Test Mode
1.  Press the [
?/1
] button to turn the power on.
2.  Press three buttons [
x
], [VOLUME +] and the [
Z
] buttons 
simultaneously.
3.  The Test Mode starts, displayed “SERVICE” on this model 
display then the menu shown below will be displayed on the 
TV screen.
    
 
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. USB Test Mode Setting
Model Name
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
: XXXX
4.  The menu above is the Remocon Diagnosis Menu screen 
which consists of fi ve main functions. At the bottom of the 
menu screen, the model name and IF-con version.
2.  Releasing Test Mode
Press the [
?/1
] button on the remote commander.
3.  Executing IOP Measurement
In order to execute IOP measurement, the following standard pro-
cedures must be followed.
1.  In power on, press three buttons [
x
], [VOLUME +] and the 
[
Z
] buttons simultaneously.
    
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. USB Test Mode Setting
Model Name
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
: XXXX
Page of 82
Display

Click on the first or last page to see other DAV-SZ1000W / HBD-SZ1000W service manuals if exist.