Sony DAV-IS50 / HCD-IS50 Service Manual ▷ View online
HCD-IS50
21
3-19. LEVER (LOADING-L/R)
two hooks
two hooks
BOTTOM VIEW
lever (loading-L)
lever (loading-R)
SPT-T (loading-R)
SPR-T (loading-L)
PRECAUTION DURING LEVER (LOADING R / L) INSTALLATION
lever (loading-R)
Align the horizontal position.
lever (loading-L)
Install the both levers so that they move symmetrically.
HCD-IS50
22
3-20. LEVER (DISC SENSOR)/(DISC STOP)
chassis (top)
hole
Install the lever (disc stop) so that the both holes
are aligned.
are aligned.
hole
gear (cap)
two claws
two hooks
lever (disc stop)
lever (disc stop)
lever (disc sensor)
PRECAUTION DURING DISC STOP LEVER INSTALLATION
gear (IDL-L)
3-21. GEAR (IDL-C)
three hooks
two claws
claw
gear (IDL-F)
gear (IDL-C)
gear (IDL-D)
lever (gear loading) assy
23
HCD-IS50
1. TEST MODES OTHER THAN THE TEST MENU
These are executable test mode even if not entering the test menu.
1-1. Cold Reset
The cold reset clears data except DVD data stored in the RAM to
initial conditions. Execute this mode when returning the set to the
customers.
Procedure:
The cold reset clears data except DVD data stored in the RAM to
initial conditions. Execute this mode when returning the set to the
customers.
Procedure:
1. In the standby state, press the [
I
/
1
] button on the set for more
than 5 seconds.
2. The messages “MEMORY CLR” and “PUSH POWER” are
displayed on the fl uorescent indicator tube.
3. When the [
I
/
1
] button is pressed in the state of step 2, the
messages “CLEARING” t “CLEARED!” are displayed,
then becomes standby states.
1-2. DVD Version View
Procedure:
Procedure:
1. Connect the set with the TV.
2. In the standby state, press the button in the order of
2. In the standby state, press the button in the order of
[ DISPLAY] t [ENTER] t [
I
/
1
] on the remote com-
mander, the DVD version appears on the TV screen.
3. To release from this mode, press the [
I
/
1
] button.
1-3. Color System Change (Except US, Canadian and
Latin American models)
This mode let you change the color system of the video output from
PAL to NTSC or vice versa.
Procedure:
PAL to NTSC or vice versa.
Procedure:
1. Press the [
I
/
1
] button to turn the power on.
2. Press the [FUNCTION] button on the remote commander to
select the “DVD”.
3. Press the [SYSTEM MENU] button on the remote com-
mander.
4. Press the [M] [m] button on the remote commander to select
the “COLOR SYS”, and press the [ ] button on the remote
commander.
commander.
5. Press the [M] [m] button on the remote commander to select
the “PAL” or “NTSC”, and press the [ ] button on the remote
commander.
commander.
6. The color system is changed.
1-4. AM Step Change (Except AEP, UK, Russian and
Saudi Arabia models)
The step interval of AM channels can be toggled between 9 kHz
and 10 kHz.
Procedure:
and 10 kHz.
Procedure:
1. Press the [
I
/
1
] button to turn the power on.
2. Press the [FUNCTION] button on the remote commander to
select the “AM”.
3. Press the [SYSTEM MENU] button on the remote com-
mander
and press the [M] [m] button on the remote commander to
select the “AM step?”, and press the [ ] button on the remote
commander.
commander.
4. The message “10k t 9k” or “9k t 10k” appears on the
fl uorescent indicator tube.
5. Press the [ ] button on the remote commander, and the AM
channel step is changed.
SECTION 4
TEST MODE
1-5. Disc Slot Lock
This mode let you lock the disc slot. When this mode is activated,
the disc will not eject when the [Z] button is pressed. The message
“LOCKED” will be displayed on the fl uorescent indicator tube.
Procedure:
This mode let you lock the disc slot. When this mode is activated,
the disc will not eject when the [Z] button is pressed. The message
“LOCKED” will be displayed on the fl uorescent indicator tube.
Procedure:
1. Press the [
I
/
1
] button to turn the power on.
2. Press the [FUNCTION] button on the remote commander to
select the “DVD”.
3. Touch the [x]
sensor and press the [Z] button on the set
simultaneously and hold down until “LOCKED” or
“UNLOCKED” displayed on the fl uorescent indicator tube
(around 5 seconds).
“UNLOCKED” displayed on the fl uorescent indicator tube
(around 5 seconds).
1-6. Demo Disc Play
Mode to prevent theft of the demonstration disc.
Setting Procedure:
It automatically enters the mode when the demonstration disc is
inserted.
Releasing Procedure:
Mode to prevent theft of the demonstration disc.
Setting Procedure:
It automatically enters the mode when the demonstration disc is
inserted.
Releasing Procedure:
1. Press the [
I
/
1
] button to turn the power on.
2. Press the [FUNCTION] button on the remote commander to
select the “DVD”.
3. Touch the [x]
and [B]
sensor on the set simultaneously and
hold down until “DEMO OFF” displayed on the fl uorescent
indicator tube (around 5 seconds).
indicator tube (around 5 seconds).
1-7. S-AIR ID Select (AEP, UK and Russian models)
This mode let you select S-AIR ID to match with the ID of
surround amplifi er.
Procedure:
This mode let you select S-AIR ID to match with the ID of
surround amplifi er.
Procedure:
1. Press the [
I
/
1
] button to turn the power on.
2. Press the button in the order of [CLEAR] t [1] t [2] t
[ANGLE] on the remote commander.
3. The message "S-AIR ID A" or "S-AIR ID B" or "S-AIR ID
C" appears on the fl uorescent indicator tube.
1-8. S-AIR Pairing (AEP, UK and Russian models)
This mode let you identify the main unit with a specifi c surround
amplifi er.
Procedure:
This mode let you identify the main unit with a specifi c surround
amplifi er.
Procedure:
1. Press the [
I
/
1
] button to turn the power on.
2. Press the button in the order of [CLEAR] t [1] t [3] t
[ANGLE] on the remote commander.
3. "S-AIR" appears on fl uorescent indicator tube.
4. To unpair, repeat step 2 and "S-AIR" disappear.
4. To unpair, repeat step 2 and "S-AIR" disappear.
2. TEST MODES IN THE TEST MENU
These are the test modes done in the test menu.
Setting method of the test menu:
Setting method of the test menu:
1. Press the [
I
/
1
] button to turn the power on.
2. Press the button in the order of [CLEAR] t [ENTER] t
[0] t [1] t [0] t [ANGLE] on the remote commander.
(Make the interval when each button is pressed within two
seconds.)
seconds.)
3. The message “TEST MENU” appears on the fl uorescent
indicator tube and enter the test menu.
2-1. Panel Test
Procedure:
Procedure:
1. Enter the test menu.
2. Press the [M] [m] button on the remote commander to select
2. Press the [M] [m] button on the remote commander to select
the “PANEL TEST”, and press the [ENTER] button on the
remote commander.
remote commander.
24
HCD-IS50
3. LEDs and segment in fl uorescent indicator tube lighted up in
the sequence of:
a. LEDs (except [B]) and all segments in fl uorescent indicator
tube are lighted up.
b. [B] and half segments in fluorescent indicator tube are
lighted
up.
c. other half segments in fl uorescent indicator tube are
lighted
up.
This operation is repeated until [
I
/
1
] button is pressed to release
from this test mode.
4. When all segments in fl uorescent indicator tube are lighted up
in the state of step 3, press the [VOLUME +] button on the
remote commander and model information is displayed on the
fl uorescent indicator tube.
remote commander and model information is displayed on the
fl uorescent indicator tube.
Each time the [VOLUME +] button on the remote commander
is pressed, the display changes in the order of destination
information, MC version, SUB version, and returns to the
model information display.
information, MC version, SUB version, and returns to the
model information display.
Each time the [VOLUME --] button on the remote commander
is pressed, the version and date are switched.
5. In the state of step 3, press the [FUNCTION] button on the
remote commander and “K 0” is displayed on the fl uorescent
indicator tube.
indicator tube.
“K 0” value increases whenever a button on the set is pressed or
a sensor is touched. However, once a button has been pressed,
it is no longer taken into account.
a sensor is touched. However, once a button has been pressed,
it is no longer taken into account.
All buttons on the set are pressed and all sensors are touched,
“OK” and “K 7” are alternately displayed on the fl uorescent
indicator tube.
indicator tube.
6. To release from this mode, press the [
I
/
1
] button.
2-2. AMP Test
Procedure:
Procedure:
1. Enter the test menu.
2. Press the [M] [m] button on the remote commander to select
2. Press the [M] [m] button on the remote commander to select
the “AMP TEST”, and press the [ENTER] button on the remote
commander.
commander.
3. The message “MEASURE” appears on the fluorescent
indicator tube and enter the AMP test mode.
4. Press the [SUBTITLE] button on the remote commander, the
message “VACS ON” or “VACS OFF” appears on the fl uores-
cent indicator tube and thus the VACS on/off are changed.
cent indicator tube and thus the VACS on/off are changed.
5. To release from this mode, press the [
I
/
1
] button.
2-3. Cold Reset
The cold reset clears data except DVD data stored in the RAM to
initial conditions. Execute this mode when returning the set to the
customers.
Procedure:
The cold reset clears data except DVD data stored in the RAM to
initial conditions. Execute this mode when returning the set to the
customers.
Procedure:
1. Enter the test menu.
2. Press the [M] [m]
2. Press the [M] [m]
button on the remote commander to select
the “COLD RESET”, and press the [ENTER] button on the
remote commander.
remote commander.
3. The message “COLD RESET.” appears on the fl uorescent
indicator tube, then becomes standby states.
2-4. Product Out
This mode moves the optical pick-up to the position durable to
vibration and clears all data including preset data stored in the RAM
to initial conditions. Use this mode when returning the set to the
customer after repair.
Procedure:
This mode moves the optical pick-up to the position durable to
vibration and clears all data including preset data stored in the RAM
to initial conditions. Use this mode when returning the set to the
customer after repair.
Procedure:
1. Enter the test menu.
2. Press the [M] [m] button on the remote commander to select
2. Press the [M] [m] button on the remote commander to select
the “PRODUCTOUT”, and press the [ENTER] button on the
remote commander.
remote commander.
3. After the “STANDBY” blinking display fi nishes, the message
“MECHA LOCK” t “UNPLUG” appears on the fl uorescent
indicator tube and the ship mode is set.
4. To release from this mode, pull out the power code.
2-5. Tuner Factory Preset
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
I
/
1
] button if having entered this mode.
2-6. Digital Media Port Test
Procedure:
Procedure:
1. Connect the DMPORT check jig (P/N: J-2501-309-A) with
the DMPORT jack (CN3802) on the DMB-FIT board.
2. Press the [
I
/
1
] button to turn the power on.
3. Confi rm that both LEDs of the DMPORT check jig lights.
(Confi rmation the power supply line)
4. Press the [FUNCTION] button on the remote commander to
select the “DMPORT”.
5. Enter the test menu.
6. Press the [M] [m] button on the remote commander to select
6. Press the [M] [m] button on the remote commander to select
the “DMPORT CHK”, and press the [ENTER] button on the
remote commander.
remote commander.
7. The message “DMPORT OK.” appears on the fl uorescent
indicator tube and enter the digital media port test mode.
(Confi rmation of communication line)
(Confi rmation of communication line)
When “NO DETECT.” and “UART .TO” are displayed on
the fl uorescent indicator tube, confi rm the connection of the
DMPORT check jig, and enter the mode again.
DMPORT check jig, and enter the mode again.
Each time the [>] button on the remote commander
is pressed, connect check and adaptor version check are
switched.
switched.
Press the [.] button on the remote commander, connection
confi rmation of the DMPORT check jig is done again.
confi rmation of the DMPORT check jig is done again.
8. To a pinjack of the DMPORT check jig input information
relevant to audio signal (sine-wave 1.0V rms) and composite
video signal (white 100% 1.0Vp-p, color bar, etc.).
video signal (white 100% 1.0Vp-p, color bar, etc.).
9. Confi rm the output of speakers and TV. (Confi rmation of
analog signal)
10. To release from this mode, press the [
I
/
1
] button.
2-7. VACS Display
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
I
/
1
] button if having entered this mode.
2-8. VACS On/off
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
I
/
1
] button if having entered this mode.
2-9. DSP Halt Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
I
/
1
] button if having entered this mode.
color
pattern
generator
DMPORT
check jig
(Part No.:
J-2501-309-A)
J001
AF
oscillator
set
(HCD-IS50)
SA-WSIS50
TV
monitor
FL/FR
speaker
DMB-FIT board
CN3802
SPEAKER board
TB101
IO board
J902
Click on the first or last page to see other DAV-IS50 / HCD-IS50 service manuals if exist.