41
HCD-SE7
SECTION 5
ELECTRICAL ADJSTMENT
DVD SECTION
AUTO SERVO ADJUSTMENT
After parts related to the servo circuit (RF amplifier (IC001), DSP
(IC509), motor driver (IC501), EEPROM (IC903) so on) are
replaced, re-adjusting the servo circuit is necessary. Select “ALL”
at  “1. DRIVE AUTO ADJUSTMENT” (Refer to page 30  in TEST
MODE) and adjust DVD-SL (single layer), CD and DVD-DL (dual
layer).
[TEST DISC LIST]
Use the following test disc on test mode.
TDV-520CSO (DVD-SL):
PART No. J-2501-236-A
LUV-P01 (CD):
PART No. 4-999-032-01
TDV-540C (DVD-DL):
PART No. J-2501-235-A
Note:
Do not use exiting test disc for DVD.
[RFMON Level Check]
Connection:
+
SUB board
oscilloscope
CN110 pin
 1
(RF)
CN110 pin 
3
(GND)
Procedure:
1. Connect an oscilloscope to CN110 pin 1 (RF) and CN110
pin 3 (GND) on the SUB board.
2. Turn the power on.
3. Set the test disc (DVD: TDV-520CSO, CD: LUV-P01) on the
tray and press NX  (DVD) button to playback.
4. Confirm that oscilloscope waveform is clear and check
RFMON signal level is correct or not.
Note:
A clear RFMON signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
RFMON signal waveform
 
VOLT/DIV: 200 mV
TIME/DIV: 500 ns 
level: 1.09 
±
  0.2 Vp-p (DVD)
1.05 
±
 0.2 Vp-p (CD)
CN111
CN110
1
3
SUB BOARD
CN110 pin
 1
(RF)
CN110 pin
 3
(GND)
(Conductor Side)
Checking Location: SUB board (Conductor Side)
42
HCD-SE7
MD SECTION
1. Parts  Replacement  and  Adjustment
If malfunctions caused by optical pick-up such as sound skipping are suspected, follow the following check.
Check before replacement
Other faults are suspected.
Check the mechanism parts (spindle motor, sled motor, etc.).
Start
NG
NG
NG
OK
OK
OK
Laser Power Check
6-2.
(See page 45)
6-3.
(See page 45)
6-4.
(See page 46)
Iop Compare
Auto Check
Replace optical pick-up or MDM-7S2D
43
HCD-SE7
Flow Chart for Adjustment
YES
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
Start
IC195 replacement
OP or IC195 replacement
IC101, IC195 or D101 
replacement
OP or IC195 
replacement
After turning the power off and on, initialises the non-volatile 
memory (EEPROM).
7. Initial setting of adjustment value (See page 48)
9. Temperature compensation offset adjustment (See page 48)
10. Laser power adjustment (See page 48)
OP, IC701 or IC195 
replacement
OP, IC101, IC201 or IC195 
replacement
OP replacement
Spindle motor replacement
6-4. Auto check (See page 46)
End
11. Iop NV save (See page 49)
12.Traverse adjustment (See page 49)
13. Focus bias adjustment (See page 50)
16. Auto gain control output level adjustment (See page 51)
In Err display mode, write OP change Iop
In Err display mode, Spdl change
•Abbreviation
OP: Optical pick-up
44
HCD-SE7
2. Precautions for Checking Laser Diode Emission
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
3. Precautions for Use of Optical Pick-Up
    (KMS-262A/262E)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when handling
it.
Before disconnecting the connector, perform soldering bridge to
the laser tap. Before connecting the connector, be careful not to
remove the solder. Also take adequate measures to prevent damage
by static electricity. Handle the flexible board with care as it breaks
easily.
4. Precautions for Adjustments
1. When replacing the following parts, perform the adjustments
and checks with 
 in the order shown in the following table.
2. Set the MD test mode when performing adjustments.
After completing the adjustments, exit the MD test mode.
Perform the adjustments and checks in “Group Service” of
the MD test mode.
3. Perform the adjustments to be needed in the order shown.
4. Use the following tools and measuring devices.
Check Disc (TDYS-1) (Part No. : 4-963-646-01)
Test Disk (MDW-74/GA-1) (Part No. : 4-229-747-01)
Laser power meter LPM-8001 (Part No. : J-2501-046-A)
or
MD Laser power meter 8010S (Part No. :  J-2501-145-A)*
1
•  Oscilloscope (Measure after performing CAL of prove.)
•  Digital voltmeter
•  Thermometer
•  Jig for checking BD board waveform
   (Part No. : J-2501-196-A)
5. When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the
oscilloscope.
(VC and ground will become short-circuited.)
6. Using the above jig enables the waveform to be checked
without the need to solder.
(Refer to Servicing Notes on page 14)
7. As the disc used will affect the adjustment results, make sure
that no dusts nor fingerprints are attached to it.
*
1
       
Laser power meter
When performing laser power checks and adjustment
(electrical adjustment), use of the new MD laser power meter
8010S (Part No. J-2501-145-A) instead of the conventional
laser power meter is convenient.
It sharply reduces the time and trouble to set the laser power
meter sensor onto the objective lens of optical pick-up.
pick-up
flexible board
laser tap
Before starting adjustment:
The adjustment value differs depending on the types (KMS-262A
or KMS-262E) of optical pickup. Be sure to confirm the type name
before starting adjustment.
pink
: KMS-262A
white : KMS-262E
UV adhesive = 
UV adhesive 
Optical pick-up
(KMS-262A/262E)
Optical pick-up flexible board
Optical
Pick-up
IC101
IC701
IC201
IC933
IC195
D101
Parts to be replaced
Adjustment
6-4. AUTO CHECK
a
a
a
a
a
7. Initial setting of adjustment value
a
a
8. Recording of Iop information
a
a
9. Temperature compensation
a
a
a
    offset adjustment
10. Laser power adjustment
a
a
a
11. Iop NV Save
a
a
a
a
12. Traverse adjustment
a
a
a
a
13. Focus bias adjustment
a
a
a
a
16. Auto gain adjustment
a
a
a
a
Page of 127
Display

Click on the first or last page to see other CMT-SE7 / HCD-SE7 service manuals if exist.