33
HCD-M373
SECTION 5
ELECTRICAL ADJUSTMENTS
4.
After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location: REC/PB Head
Tape Speed Check
Procedure:
1.
MODE : FWD Playback.
2.
Insert the WS-48B into deck.
3.
Press the  TAPE Y  button of deck.
4.
Check the reading of frequency counter becomes 3000 ± 90
Hz.
Sample Value of Wow and flutter
W.RMS (JIS) less than 0.35%
(test tape: WS-48B)
3.
Mode: Playback
test tape
P-4-A100
(10kHz, –10dB)
oscilloscope
set
Waveform of oscilloscope
in phase
45
°
90
°
135
°
180
°
good
wrong
R-ch
L-ch
V
H
Pin     (GND)
MAIN board
CN105
Pin     (L-CH) 
4
6
2
Pin     (R-CH)
test tape
WS-48B
(3kHz, 0dB)
frequency
counter
set
Pin     (GND)
4
6
2
MAIN board 
CN105
Pin     (L-CH) or
Pin     (R-CH)
Note:
 DSG OFF, TREBLE/BASS CENTER
Record/Playback Head Azimuth Adjustment
Procedure:
1.
Mode : Playback
2.
Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1 dB of peak.
L-CH
peak
R-CH
peak
screw
position
output
level
within
1 dB
L-CH
peak
R-CH
peak
screw
position
within 1dB
TAPE SECTION
0 dB=0.775V
1.
Demagnetize the record/playback head with a head demagne-
tizer.
2.
Do not use a magnetized screwdriver for the adjustments.
3.
After the adjustments, apply suitable locking compound to the
parts adjusted.
4.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5.
The adjustments should be performed in the order given in this
service manual. (As a general rule, playback circuit adjustment
should be completed before performing recording circuit ad-
justment.)
6.
The adjustments should be performed for both L-CH and R-
CH.
7.
Switches and controls should be set as follows unless other-
wise specified.
test tape
P-4-A100
(10kHz, –10dB)
level meter
set
+
Pin     (GND)
MAIN board 
CN105
Pin     (L-CH) or
Pin     (R-CH)
4
6
2
Tape
P-4-A100
WS-48B
10 kHz, –10 dB
3 kHz, 0 dB
Azimuth Adjustment
Tape Speed Adjustment
Signal
Used for
34
HCD-M373
Record Bias Adjustment
Procedure :
1. Press the  FUNCTION  button to select ANALOG IN.
2. Insert a tape into deck, press the  z TAPE  button, and then
press the  X TAPE  button to start recording.
3. Mode : Record
4. Mode : Playback
5. Confirm playback the signal recorded in step  become adjustment
level as follows
If these levels do not satisfy adjustment level, adjust the RV653
(L-CH) and RV603 (R-CH) on the TC board to repeat steps 3
and 4.
Adjustment level : The playback output of 10kHz level difference
against 315Hz reference should be 0 
± 2.0dB.
Adjustment Location :
[MAIN BOARD]
AF OSC
ANALOG IN  (SJ302) 
1) 315 Hz
2) 10 kHz
blank tape
CS-123
set
attenuator
600 
34.6 mV (–27 dB)
recorded
position
level meter
set
Pin     (GND)
MAIN board 
CN105
Pin     (L-CH) or
Pin     (R-CH)
4
6
2
CN105
19
18
1
2
Record Level Adjustment
Procedure :
1. Press the  FUNCTION  button to select ANALOG IN.
2. Insert a tape into deck, press the  z TAPE  button, and then
press the  X TAPE  button to start recording.
3. Mode : Record
4. Mode : Playback
5. Confirm playback the signal recorded in step  become adjustment
level as follows
If these levels do not satisfy adjustment level, adjust the RV652
(L-CH) and RV602 (R-CH) on the TC board to repeat steps 3
and 4.
Adjustment level :
playback Level : 30.8 to 38.8mV (–28 to –26dB).
Adjustment Location :
[TC BOARD]
AF OSC
ANALOG IN  (SJ302) 
315 Hz
blank tape
CS-123
set
attenuator
600 
34.6 mV (–27 dB)
recorded
position
level meter
set
Pin     (GND)
MAIN board 
CN105
Pin     (L-CH) or
Pin     (R-CH)
4
6
2
RV652
(L-CH)
RV602
(R-CH)
RV653
(L-CH)
RV603
(R-CH)
Record Level
Record Bias
35
HCD-M373
E-F Balance (1 Track jump) Check
Procedure:
1.
Connect an oscilloscope to TP (TE) and TP (DVC).
2.
Turn the power on.
3.
Load a disc (YEDS-18) and playback the number five track.
4.
Press the  CD u  button. (Becomes the 1track jump mode.)
5.
Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
Specification level:      
x
 100=less than ±22%
Ajustment Location :
[BD (CD) BOARD] — SIDE A —
0V
Center of
waveform
B
Symmetry
A (DC voltage)
level=1.1 
±
0.6Vp-p
A
B
CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
Ω impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
RF Level Check
Procedure :
1. Connect an oscilloscope to TP (RFAC) and TP (DVC).
2. Turn the power on.
3. Load a disc (YEDS-18) and playback the number five track.
4. Confirm that oscilloscope waveform is clear and check RF signal
level is correct or not.
Note:
Clear RF signal waveform means that the shape “
◊” can be
clearly distinguished at the center of the waveform.
TP(RFAC)
TP(DVC)
BD (CD) BOARD
oscilloscope
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.1 
±
 0.3Vp-p 
BD (CD) BOARD
Oscilloscope
TP (TE)
TP (DVC)
IC101
IC103
IC104
TP (DVC)
TP (TE)
TP (RFAC)
36
HCD-M373
Other faults are suspected.
Check the mechanism parts (spindle motor, sled motor, etc.).
Start
NG
NG
NG
OK
OK
OK
Laser Power Check
6-2.
(See page 39)
6-3.
(See page 39)
6-4.
(See page 40)
Iop Compare
Auto Check
Replace optical pick-up or MDM-7S2D
MD  SECTION
Note 1:
About “R”
As this unit has only a few buttons, some operations require the use of remote commander (RM-SM100EW/provided with unit) buttons.
These operations are indicated as “R” in this manual.
Example: MENU/NO “R” ...Press the  MENU/NO  button of the remote commander.
Note 2:
Incorrect operations may be performed if the MD test mode is not entered properly.
In this case, press the ?/1 button to turn the power off, and retry to enter the MD test mode.
1. Parts  Replacement  and  Adjustment
If malfunctions caused by optical pick-up such as sound skipping are suspected, follow the following check.
Check before replacement