Sony CMT-F3MD / HCD-F3MD Service Manual ▷ View online
6
DRAWING OUT THE TRAY WHEN THE POWER IS OFF
CLEANING THE OPTICAL PICK-UP (CD PLAYER)
tray (CDM)
Move the cam block in the direction
of arrow
of arrow
A
with a finger.
A
CD mechanism deck
floating screw
(PTPWH M2.6)
(PTPWH M2.6)
optical pick-up block
Clean the lens block
with a cotton bud.
with a cotton bud.
7
SERVICE POSITION OF THE MD MECHANISM
DECK
DECK
SERVICE POSITION OF THE CD MECHANISM
DECK
DECK
MD mechanism deck
CD mechanism deck
SERVICE POSITION OF THE POWER BOARD
MAIN board
POWER board
CN993
CN802
Extension cable (4P)
(J-2501-042-A)
(J-2501-042-A)
Extension cable (3P)
(J-2501-045-A)
(J-2501-045-A)
AMP board
8
MC COLD RESET
• The cold reset clears all data including preset data stored in the RAM to initial conditions. Execute this mode when returning the set to
the customer.
Procedure:
1. Press the
1. Press the
I/1
button to turn the power on.
2. While pressing the
[PLAY MODE/TUNING MODE]
and
s
(CD) buttons, press the
I/1
button.
3. The set is reset, and displays “COLD RESET”, then becomes standby status.
MC HOT RESET
•
This mode resets the set with the preset data kept stored in the memory. The hot reset mode function is same as if the power cord is plugged
in and out.
in and out.
Procedure:
1. Press the
1. Press the
I/1
button to turn the power on.
2. While pressing the
[PLAY MODE/TUNING MODE]
and
HS
(CD) buttons, press the
I/1
button.
3. The set is reset, and becomes standby state.
LED/FLUORESCENT INDICATOR TUBE AND KEY TEST
Procedure:
1. Press the
1. Press the
I/1
button to turn the power on.
2. While pressing the
[PLAY MODE/TUNING MODE]
and
A
(CD) buttons, press the
I/1
button.
3. LEDs and fluorescent indicator tube are all turned on.
4. Press the
4. Press the
HS
(MD) button to enter the key test mode, and display “Key0 Vol0”.
5. Each time a button is pressed, “Key” value increases. However, once a button is pressed, it is no longer taken into account.
“Vol” value increases like 0, 1, 2 ... if turn the
[VOLUME]
knob clockwise, or it decreases like 9, 8, 7 ... if turn the
[VOLUME]
knob
counterclockwise.
6. To release from this mode, press three buttons in the same manner as step 2, or disconnect the power cord.
Note:
l m
and
M L
buttons are no longer taken into account, if it pressed within for a second.
CHANGE-OVER THE AM TUNING INTERVAL
• The AM tuning interval can be changed over 9 kHz or 10 kHz.
Procedure:
1. Press the
Procedure:
1. Press the
I/1
button to turn the power on.
2. Press the
[FUNCTION]
button to set the TUNER function, and press the
[TUNER/BAND]
button to select the band “AM”.
3. Press the
I/1
button to turn the power off.
4. When the power off, press the
I/1
button while pressing the
[PLAY MODE/TUNING MODE]
button, and the display of fluorescent
indicator tube changes to “AM 9k STEP” or “AM 10k STEP”, and thus the tuning interval is changed over.
9
MD SECTION
JIG FOR CHECKING BD (MD) BOARD WAVEFORM
The special jig (J-2501-149-A) is useful for checking the waveform of the BD (MD) board. The names of terminals and the checking items
to be performed are shown as follows.
to be performed are shown as follows.
GND : Ground
I+3V : For measuring IOP (Check the deterioration of the optical pick-up laser)
IOP : For measuring IOP (Check the deterioration of the optical pick-up laser)
TEO : Tracking error signal (Traverse adjustment)
VC
I+3V : For measuring IOP (Check the deterioration of the optical pick-up laser)
IOP : For measuring IOP (Check the deterioration of the optical pick-up laser)
TEO : Tracking error signal (Traverse adjustment)
VC
: Reference level for checking the signal
RF
: RF signal (Check jitter)
CN110
RF
5P connector
6P connector
VC
TEO
IOP
I+3V
GND
Mechanism deck
RF
VC
TEO
VC
TEO
for
MDM-3
MDM-3
for
MDM-5
MDM-5
IOP
I+3V
I+3V
VC
RF
TEO
IOP
I+3V
GND
RF
TEO
IOP
I+3V
GND
VC
RF
TEO
IOP
I+3V
GND
1
5
1
6
Click on the first or last page to see other CMT-F3MD / HCD-F3MD service manuals if exist.