DOWNLOAD Sony CFD-V27 Service Manual ↓ Size: 6.1 MB | Pages: 57 in PDF or view online for FREE

Model
CFD-V27
Pages
57
Size
6.1 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cfd-v27.pdf
Date

Sony CFD-V27 Service Manual ▷ View online

— 13 —
15
7
4
1
30
16
IC1
CV1
CF1
L1
FM Tracking
Adjustment
L2
FM Frequency
Coverage
Adjustment
T2
AM IF
Adjustment
L4
AM Frequency
Coverage
Adjustment
RV1
FM VCO
Adjustment
L3
AM Tracking
Adjustment
FM ANT IN
T1
FM IF
Adjustment
AM OSC
AM OSC
FM OSC
FM OSC
CT4
AM Frequency
Coverage
Adjustment
CT3
AM Tracking
Adjustment
CT1
FM Tracking
Adjustment
CT2
FM Frequency
Coverage
Adjustment
Set the CT2 (FM OSC) and CT4 (AM OSC)
trimmers to their extreme outside.
Inside NG
Outside OK
Adjustment Location : MAIN board (Component side)
Adjustment Location : MAIN board (Conductor side)
— 14 —
Notes on Check
1.
Perform the traverse check in the CD test mode.
After check, be sure to exit the test mode.
2.
Perform check in the order given.
3.
Use the disc (YEDS-18, Parts No. 3-702-101-01) only when
so indicated.
Before Check
Put the set into test mode and perform the following  checks.
Repair if there are any problems.
• Sled Motor Check
Press 
+ , = keys and confirm that the Optical pick-up  moves
smoothly from the innermost to outermost circumference and back
smoothly and with no catching or abnormal noises.
(Cancellation of BTL mute)
+ : Optical pick-up moves to the outer circumference.
= : Optical pick-up moves to the inner circumference.
Focus Search Check
1.
Press the CD 
^ key. (Focus search operation is performed
continuously.)
2.
Look at the Optical pick-up objective lens and confirm that it
moves up and down smoothly, with no catching or abnormal
noises.
3.
Press 
p button.
Confirm that focus search operation stops. If it does not, press
p button again longer.
How to Enter the Set into Test Mode
1.
Set the function switch to power off.
2.
Set the function switch to CD while 
= key and p key
pressing.
The set is into CD test mode (
88 is displayed).
3.
Turn the power off to release test mode.
How to Exit the Test Mode
Turn the POWER OFF.
CD SECTION
TRAVERSE Check
This check is to be done when the optical pick-up block is replaced.
Check Procedure:
1.
Connect the oscilloscope to test point TP (VC) and TP (TE) on
MAIN board.
2.
Put the set into test mode.
3.
Optical pick-up setting to the center by 
+ or = button
pushing.
4.
Insert disk (YEDS-18) and press 
^ button.
5.
Check that the oscilloscope traverse waveform is symmetrical,
as shown in the figure below.
6.
Release test mode after adjustment is completed.
[MAIN BOARD] (Conductor side)
A
B
C
0V
VOLT/DIV : 0.1V
TIME/DIV  : 1ms
A = B     C = 300mV – 700mV
+
Oscilloscope
(DC range)
TP (VC)
TP (TE)
TP (FE)
— 15 —
Focus Bias Check
This check is to be done when the optical block replaced.
Check Procedure:
1. Connect the oscilloscope to test point TP (VC) and TP (RF) on
MAIN board.
2. Put the set into test mode.
3. Opitical pick-up setting to the center by + or – button pushing.
4. Insert disk (YEDS-18) and press 
^ button.
5. Press the MODE button. (Tracking servo ON)
6. Check that the oscilloscope wavewform is as shown in the figure
below (eye pattern).
A good eye pattern means that the diamond shape (
) in the
center of the waveform can be clearly distinguished.
7. Release test mode after adjustment is completed.
• RF signal reference waveform (eye pattern)
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensivity.
[MAIN BOARD] (Conductor side)
5-4.
REFERENCE
Focus/Tracking Gain Check
Adjustment Location : MAIN board (Component side)
(See page 16)
A frequency response analyzer is necessary in order to perform this
check exactly.
However, this gain has a margin, so even if it is slightly off, there is
no problem.
Focus/Tracking gain determines the pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock when
the 2-axis device operate.
Tracking
Gain
Symptoms
Focus
•  The time until music starts
becomes longer for STOP ➡
CD 
^ or automatic
selection (
0 , ) buttons
pressed). (Normally takes
about 2 seconds.)
•  Music does not start and disc
continues to rotate for STOP
➡ CD ^ or automatic
selection (
0 , ) buttons
pressed.)
•  Sound is interrupted during
PLAY. Or time counter
display stops progressing.
•  More noise during 2-axis
device operation.
low
high
low or high
low
low
high
Check Procedure:
1. Keep the set horizontal.
2. Inset disk (YEDS-18) and press 
^ button.
3. Connect an oscilloscope to TP (FE) and TP (VC) on the MAIN
board.
4. Check that the waveform is as shown in the figure below. (Focus
waveform)
VOLT/DIV : 0.2V
TIME/DIV : 500ns
0.9Vp-p – 1.3Vp-p
+
Oscilloscope
(DC range)
TP
(RF)
TP(VC)
— 16 —
Good Example
Incorrent Examples (DC level changes more than on adjusted
waveform)
5.
Connect an oscilloscope between TP (TE) and TP (VC).
6.
Insert disc (YEDS-18) and press the CD 
^ button.
7.
Check that the waveform is as shown in the figure below.
(tracking waveform)
low focus gain
high focus gain
low tracking gain
high tracking gain
(high fundamental wave than for low gain)
[MAIN BOARD] (Conductor side)
Incorrect Examples (Fundamental wave appears)
100mV
0V
VOLT/DIV : 100mV
TIME/DIV : 1ms
VOLT/DIV : 100mV
TIME/DIV : 2ms
200mV
0V
VOLT/DIV : 100mV
TIME/DIV : 2ms
75mV
0V
VOLT/DIV : 0.2V
TIME/DIV : 2ms
0V
VOLT/DIV : 0.2V
TIME/DIV : 2ms
0V
VOLT/DIV : 0.2V
TIME/DIV : 2ms
0V
+
Oscilloscope
(DC range)
TP (VC)
TP (TE)
TP (FE)
Page of 57
Display

Click on the first or last page to see other CFD-V27 service manuals if exist.