13
CFD-S20CP
3-14. MOTOR ASSY (M801), MAIN BELT (B), SUB BELT (B)
3-13. R/P HEAD (HRP301), TC BOARD
2
 BVTP 2x4
1
 R/P head (HRP301)
3
 TC board
4
 Removal the solders.
claws
lug
1
 bind DT M2x6
2
 bind DT M2x6
5
 pan M2.6x4.5
3
 main belt (B)
4
 sub belt (B)
6
 motor assy (M801)
14
CFD-S20CP
jack (J321)
set
32 
test tape
WS-48A
(3 kHz, 0 dB)
digital frequency
counter
  TAPE SECTION     0 dB = 0.775 V
• Standard Output Level
Output terminal
HP OUT
load impedance
32 
output signal level
0.25 V (–10 dB)
• Test Tape
Type
Signal
Used for
WS-48A
3 kHz, 0 dB
tape speed adjustment
Tape Speed Adjustment
Procedure:
Mode: playback
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head magnetizer close to the erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the rated power
supply voltage (9V) unless otherwise noted.
Torque Measurement
Mode
Torque meter
Meter reading
2.95 – 6.86 mN • m
FWD
CQ-102C
(30 – 70 g • cm)
(0.42 – 0.97 oz • inch)
FWD
0.15 – 0.53 mN • m
Back Tension
CQ-102C
(1.5 – 5.5 g • cm)
(0.021 – 0.076 oz • inch)
more than 5.88 mN • m
FF
CQ-201B
(more than 60 g • cm)
(more than 0.83 oz • inch)
more than 5.88 mN • m
REW
CQ-201B
(more than 60 g • cm)
(more than 0.83 oz • inch)
Tape Tension  Measurement
Mode
Tension meter
Meter Reading
FWD
CQ-403A
more than 100 g
(more than 3.53 oz)
SECTION 5
ELECTRICAL ADJUSTMENTS
SECTION 4
MECHANICAL ADJUSTMENTS
Adjust so that the value on the digital frequency counter is
3,000 Hz.
Specification Value:
Digital frequency counter
2,940 to 3,060 Hz
Adjust so that the frequency at the beginning and that at the end of
tape winding are between 2,970 to 3,030 Hz.
Adjustment Location:
Tape speed adjustment
control inside motor
15
CFD-S20CP
digital
voltmeter
100 k
TP (VT)
i
 jack (J321)
set
32 
level meter
(range: 0.5–5 V ac)
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
TP (FM IN)
FM RF signal
generator
0.01 
µ
F
set
  TUNER SECTION     0 dB = 1 µV
• FM Section
Setting:
RADIO BAND•AUTO PRESET button: FM
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
• AM Section
Setting:
RADIO BAND•AUTO PRESET button: MW or LW
30% amplitude
modulation by
400 Hz signal
• Connecting Level Meter (FM, MW and LW)
• Connecting Digital Voltmeter (FM, MW and LW)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.3 ± 0.3 V
3.0 ± 0.2 V
Adjustment Part
<confirmation>
L2
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
MW FREQUENCY COVERAGE
CHECK
Frequency Display
531 kHz
1,611 kHz
Reading on Digital voltmeter
1.0 ± 0.5 V
5.2 ± 0.6 V
Adjustment Part
<confirmation> <confirmation>
MW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-1
CT3
621 kHz
1,404 kHz
LW FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
153 kHz
279 kHz
Reading on Digital voltmeter
0.6 ± 0.3 V
5.0 ± 0.1 V
Adjustment Part
<confirmation>
L4
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-2
CT5
162 kHz
261 kHz
Adjustment Location: See page 16.
16
CFD-S20CP
Adjustment Location:
  CD SECTION
CD section adjustments are done automatically in this set.
In case of operation check, confirm that focus bias.
FOCUS BIAS CHECK
1. Connect the oscilloscope between IC701 pin 4 and pin qa (or
TP (RF) and TP (VREF)).
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the N X (CD) button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (     ) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
Test Point:
RF level :
0.85 
±
 0.2 Vp-p
VOLT/DIV : 50 mV (10 : 1 probe in use)
TIME/DIV : 500 nS
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
L4
TP (FM IN)
(CONDUCTOR SIDE)
CT1
IC1
IC2
CT3
CT5
L1
L2
T2
T1
L3-2
L3-1
– MAIN board (component side) –
L4
LW
FREQUENCY
COVERAGE
ADJUSTMENT
L2
FM
FREQUENCY
COVERAGE
ADJUSTMENT
CT5, L3-2
LW
TRACKING
ADJUSTMENT
CT3, L3-1
MW
TRACKING
ADJUSTMENT
CT1, L1
FM
TRACKING
ADJUSTMENT
T1
MW
IF
ADJUSTMENT
T2
FM
IF
ADJUSTMENT
TP (VT)
(CONDUCTOR SIDE)
R702
R704
R706
R708
R709
R711
R729
R730
R745
C701
C7
C705
C706
C740
C710
C711
C712
C713
C714
C716
C717
C718
C719
C720
C721
R710
R755
R757
R759
R724
R725
R726
R727
R728
R732
R733
R734
R735
R736
R737
R740
R1001
R1002
R1003
R1004
R10
C708
C746
C742
C743
C744
C760
C761
C762
C763
C764
C766
C767
C737
C732
C733
C722
C756
C1066
C1067
C1068
C1069
C10
C
1074
R763
R764
R723
IC701
R765
FB1001
1
002
FB703
FB704
CNP701
C707
C715
C709
TP(RF)
TP
(VREF)
TP
(FE)
TP
(TE)
TX
TY
FX
FY
SPX
SPY
SLX
SLY
TP
(RF)
TP
(VREF)
TP
(TE)
– CD board (conductor side) –