DOWNLOAD Sony CFD-E95 Service Manual ↓ Size: 3.2 MB | Pages: 61 in PDF or view online for FREE

Model
CFD-E95
Pages
61
Size
3.2 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cfd-e95.pdf
Date

Sony CFD-E95 Service Manual ▷ View online

13
CFD-E95
3-10. R/P  HEAD (HRP301)
3-9.
TAPE  MECHANISM  DECK
(MF-E95)
7
four screws
(2.6 
×
 8)
5
screw (2.6 
×
 8)
9
three buttons (MD)
(pause, stop/eject, REW)
0
three buttons (MD)
(FWD, play, REC)
4
two screws
(2.6)
3
two screws (2.6)
6
panel section
1
Push the button 
(MD) (stop/eject).
qa
tape mechanism deck
(MF-E95)
8
2
5
two claws
6
R/P head (HRP301)
blade
1
screw
(2 
×
 4)
tape mechanism deck
2
harness
3
Remove four solders.
hook
4
TC board
14
CFD-E95
3-12. CD  LID
3-11. MAIN  BELT  (B),  SUB  BELT  (B)
8
main belt (B)
9
sub belt (B)
1
screw (2 
×
 4)
5
screw (2.6 
×
 4.5)
6
screw (2.6 
×
 4.5)
tape mechanism deck
7
motor block
2
harness
3
Remove four solders.
4
TC board
3
CD spring
4
boss
7
CD lid
CD lid
driver
5
boss
6
two bosses
1
screw (2.6 
×
 10)
2
damper
15
CFD-E95
SECTION  4
MECHANICAL  ADJUSTMENTS
SECTION  5
ELECTRICAL  ADJUSTMENTS
TAPE  SPEED  ADJUSTMENT
Setting:
Function: TAPE
Procedure:
1. Playback WS-48B (tape center) in the FWD state.
2. Adjsut the volume in CAPSTAN/REEL motor (M301) so that
the frequency counter reading becomes 3,000 Hz.
Specified Value: 2,910 to 3,090 Hz
3. Confirm that the frequency at the beginning and that at the
end of tape winding are between 2,940 to 3,060 Hz.
Adjustment Location:
PRECAUTION
1. Setting
MEGABASS control : OFF
TAPE  DECK  SECTION
0 dB=0.775 V
Test tape
Type
Signal
Used for
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
+
set
Test tape
WS-48B
(3 kHz, 0 dB)
frequency counter
3.2 
RELAY board
CNP325 pin 
2
RELAY board
CNP325 pin 
1
Tape speed
Adjustment
CAPSTAN/REEL motor
(M301)
– TAPE deck block –
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 100 g
(more than 3.53 oz)
• Tape Tension  Measurement
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head magnetizer close to the erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
• Torque Measurement
Mode
Torque Meter
Meter Reading
2.95 – 6.86 mN•m
FWD
CQ-102C
(30 – 70 g•cm)
(0.42 – 0.97 oz•inch)
0.15 – 5.39 mN•m
FWD
CQ-102C
(1.5 – 5.5 g•cm)
Back Tension
(0.021 – 0.076 oz•inch)
more than 5.89 mN•m
FF
CQ-201B
(more than 60 g•cm)
(more than 0.83 oz•inch)
more than 5.89 mN•m
REW
CQ-201B
(more than 60 g•cm)
(more than 0.83 oz•inch)
Sample Value of Wow and Flutter: 0.3% or less W.RMS (JIS)
(WS-48B)
16
CFD-E95
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
(
): Singapore, Taiwan, Korean, Australian model
AM VCO VOLTAGE ADJUSTMENT
Frequency Display
Reading on Digital Voltmeter
530 (531) kHz
1.0 ± 0.1 V
1,710 (1,611) kHz
5.3 ± 0.7 V
(
): Singapore, Taiwan, Korean, Australian model
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L3
620 (621) kHz
CT3
1,400 (1,404) kHz
FM IF ADJUSTMENT
Adjust for a minimum reading on level meter
T2
10.7 MHz
FM VCO VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L2
108 MHz
3.0 ± 0.2 V
Confirmation
87.5 MHz
1.3 ± 0.3 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
87.5 MHz
CT1
108 MHz
Adjustment Location: TUNER and RELAY board (See page 17)
TUNER  SECTION
0 dB=1 
µ
V
[AM]
Setting:
Function : RADIO
BAND button : AM
[FM]
Setting:
Function : RADIO
BAND button: FM
• Repeat the procedures in each adjustment several times, and the
tracking adjustments should be finally done by the trimmer ca-
pacitors.
• Remove FM antenna in FM adjustment.
AM RF signal 
generator
30% amplitude
modulation by
400 Hz signal
Output level: 
as low as possible
Put the lead-wire
antenna close to 
the set.
+
level meter
set
3.2 
RELAY board
CNP325 pin 
2
RELAY board
CNP325 pin 
1
FM RF signal
generator
22.5 kHz frequency
deviation by 400 Hz
signal
Output level: 
as low as possible
+
level meter
RELAY board
CNP325 pin 
2
RELAY board
CNP325 pin 
1
set
3.2 
0.01 
µ
F
TUNER board
TP (GND)
TUNER board
TP (ANT)
digital voltmeter
TP (VT)
TP (GND)
100 k
TUNER board
Page of 61